Skip to content
Temperature Sensing & Control · IEC 60730 / IEC 60335 / RoHS

NTC Thermistor Sensors for 80-120 °C

Which insulation systems hold 80 °C to 120 °C continuously, what this construction is rated to, and the control and cut-out that hold the surface there.

NTC Thermistor Sensors are rated 200 °C continuous, which covers 80 °C to 120 °C. Battery operating windows, incubators, fluid warming and display heating. The upper limit of PET film, and the band where a low-cost printed heater stops being a candidate.

Working band
80 °C to 120 °C
Continuous limit, this construction
200 °C
Total thickness
Component
Maximum outline, one piece
Component

The band is the temperature the heated surface has to hold, not the temperature the element reaches. The element always runs hotter, by an amount the watt density and the thermal path decide, so the cut-out is set against the element and not against the load.

NTC Thermistor Sensors — the construction this guide is about

Duty temperature decides the construction before anything else does. At 80 °c to 120 °c, ntc thermistor sensors is a candidate; the sections below set out what it will hold, what has to be true for it to hold it, and what fails first when it does not.

What the 80 °C to 120 °C Band Requires

Battery operating windows, incubators, fluid warming and display heating. The upper limit of PET film, and the band where a low-cost printed heater stops being a candidate.

Band80 °C to 120 °C
This construction, continuous200 °C

The band sits comfortably inside the 200 °C ceiling, which is where a heater should be specified: the margin between the working temperature and the insulation limit is what absorbs a poor thermal path, a warm ambient and a control overshoot without shortening the life of the part.

Why the Boundary Is Where It Is

120 °C is where PET film stops. The polyester softens from about 130 °C and loses its dielectric strength as it softens, so the margin between working temperature and failure is thin — and a failure here is an electrical one, not a cosmetic one.

This is therefore the last band in which the cheapest thin heater is a candidate. Above it, the construction changes to silicone or polyimide, and the cost per square metre changes with it.

What an NTC Thermistor Sensors Is

The 10K B3950 thermistor is the default sensor on a low voltage heater: cheap, sensitive, and readable by any microcontroller with one resistor.

A sensing component, specified by its tolerance class, its usable range and its response time. It has no watt density and no outline; it is fitted to a heater or to the surface the heater is warming, and where it is fitted decides what the control loop is actually controlling.

The heat leaves through whatever the component is clamped or bonded to; a sensing component adds no heat of its own and simply has to be in thermal contact with the thing it is reporting on.

Total thicknessComponent
Maximum size, one pieceComponent
Continuous working temperature200 °C

The continuous limit of 200 °C is set by the insulation system. The element alloy would run far hotter; it is never the element that decides.

Which Temperature Is Being Held

Three temperatures matter and they are not the same number: the element temperature, the temperature of the surface being heated, and the ambient. A heater rated for a continuous working temperature is rated at the element — the hottest point in the assembly, and the one nothing on the outside is measuring.

The gap between element and surface is the thermal path. Bonded to metal it may be a few degrees; across an air gap, a void in the adhesive or a dry clamped joint it can be tens of degrees, and every one of them appears at the element rather than at the load.

Control and Protection

This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.

The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.

Where This Construction Is the Wrong Answer

  • Do not plan on running above 200 °C. That ceiling belongs to the insulation system, not to the element alloy, and it is not a figure that derating extends — past it the insulation degrades and the dielectric strength goes with it.
  • Do not rate this component as though it were the heater. It carries a contact rating or a tolerance class; the heater next to it decides the power, the watt density and the temperature the assembly reaches.

Other Constructions That Hold 80 °C to 120 °C

Constructions in this catalogue that will hold 80 °c to 120 °c continuously:

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • The temperature to be sensed or switched, and the tolerance the application actually needs.
  • Where the component sits — against the element, in the potting, on the load, or in the airflow.
  • The electrical duty: for a switching device, the voltage, the current and whether the load is AC or DC.
  • Lead length, insulation and termination, and whether the component is fitted by us into a heater assembly or supplied loose.
  • The standard the end product is certified to, so the component chosen is one that fits inside that approval.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

NTC Thermistor Sensors — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
TypeNegative temperature coefficient thermistorResistance falls as temperature rises, steeply
Standard part10 ku03a9 at 25 u00b0C, B25/50 = 3950 KThe value nearly every controller expects by default
Other values5 ku03a9, 50 ku03a9, 100 ku03a9; B values 3435 K to 4100 KChosen to match the controller, not the heater
Toleranceu00b11% resistance, u00b11% B valueu00b10.5 u00b0C interchangeable parts available
Temperature range-40 u00b0C to +200 u00b0C depending on encapsulationEpoxy bead to +125 u00b0C, glass bead to +200 u00b0C
Response time1 to 10 seconds depending on mass and mountingMounting dominates: a sensor in air reads air
EncapsulationEpoxy bead, glass bead, or laminated into the heaterLaminated is what makes it read the element
LeadsPTFE or silicone insulated, to your length and termination

Figures are the published tolerance and rating bands of the standard sensor and control components fitted to these heaters. Sensor tolerance classes follow IEC 60751 for RTDs and IEC 60584 for thermocouples; thermostat and thermal cutoff ratings are the component manufacturers' own.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.
Our facility

Where these heaters are actually made

Circuit layout, element preparation, lamination and vulcanising, die cutting and lead attachment all happen under one roof, so a watt density limit and a temperature ceiling are set by processes we control and can evidence, not by whichever supplier had stock.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (IEC 60730 / IEC 60335 / RoHS)

ParameterSpecificationLimit / note
TypeNegative temperature coefficient thermistorResistance falls as temperature rises, steeply
Standard part10 ku03a9 at 25 u00b0C, B25/50 = 3950 KThe value nearly every controller expects by default
Other values5 ku03a9, 50 ku03a9, 100 ku03a9; B values 3435 K to 4100 KChosen to match the controller, not the heater
Toleranceu00b11% resistance, u00b11% B valueu00b10.5 u00b0C interchangeable parts available
Temperature range-40 u00b0C to +200 u00b0C depending on encapsulationEpoxy bead to +125 u00b0C, glass bead to +200 u00b0C
Response time1 to 10 seconds depending on mass and mountingMounting dominates: a sensor in air reads air
EncapsulationEpoxy bead, glass bead, or laminated into the heaterLaminated is what makes it read the element
LeadsPTFE or silicone insulated, to your length and termination

Video: NTC Thermistor Sensors for 80-120 °C

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

Which heaters work at 80 °c to 120 °c?

Battery operating windows, incubators, fluid warming and display heating. The upper limit of PET film, and the band where a low-cost printed heater stops being a candidate.

Is the temperature rating the surface temperature or the element temperature?

The element temperature, which is the hottest point in the assembly and the one nothing on the outside is measuring. The surface being heated sits below it by whatever the thermal path costs — a few degrees through a good bond, tens of degrees across a void or a dry clamped joint.

What is the maximum temperature of ntc thermistor sensors?

200 °C continuous, measured at the element. The limit belongs to the insulation system and not to the element alloy, so it is not a figure that can be extended by derating the power.

Does this heater need a thermostat?

Yes. It has no mechanism for limiting its own temperature — with the load removed or the control loop failed it keeps producing the same power — so the design needs a controller with a sensor to hold the set point and, separately, a bimetal thermostat or a one-shot thermal cutoff in series with the element as protection.

How do I request a quotation?