Skip to content
Silicone Rubber Heaters · UL 499 / IEC 60335 / RoHS

Battery Pack Silicone Heaters for 80-120 °C

Which insulation systems hold 80 °C to 120 °C continuously, what this construction is rated to, and the control and cut-out that hold the surface there.

Battery Pack Silicone Heaters are rated 200 °C continuous, a limit set by the fibreglass-reinforced silicone rubber, which covers 80 °C to 120 °C. Battery operating windows, incubators, fluid warming and display heating. The upper limit of PET film, and the band where a low-cost printed heater stops being a candidate.

Working band
80 °C to 120 °C
Continuous limit, this construction
200 °C
Set by
Fibreglass-reinforced silicone rubber
Watt density
0.3 W/cm² free air, 2 W/cm² bonded
Total thickness
1.2 mm
Maximum outline, one piece
500 x 1000 mm (one piece)

The band is the temperature the heated surface has to hold, not the temperature the element reaches. The element always runs hotter, by an amount the watt density and the thermal path decide, so the cut-out is set against the element and not against the load.

Battery Pack Silicone Heaters — the construction this guide is about

Working temperature page for battery pack silicone heaters at 80 °c to 120 °c. What survives this band, what stops just below it, why the boundary is where it is, and how the temperature is actually measured and held.

What the 80 °C to 120 °C Band Requires

Battery operating windows, incubators, fluid warming and display heating. The upper limit of PET film, and the band where a low-cost printed heater stops being a candidate.

Band80 °C to 120 °C
This construction, continuous200 °C
Limited byfibreglass-reinforced silicone rubber

The band sits comfortably inside the 200 °C ceiling, which is where a heater should be specified: the margin between the working temperature and the insulation limit is what absorbs a poor thermal path, a warm ambient and a control overshoot without shortening the life of the part.

Why the Boundary Is Where It Is

120 °C is where PET film stops. The polyester softens from about 130 °C and loses its dielectric strength as it softens, so the margin between working temperature and failure is thin — and a failure here is an electrical one, not a cosmetic one.

This is therefore the last band in which the cheapest thin heater is a candidate. Above it, the construction changes to silicone or polyimide, and the cost per square metre changes with it.

What a Battery Pack Silicone Heaters Is

Low watt density silicone heaters shaped to a cell block or module face, for holding a lithium pack above its charging floor in cold weather.

Nichrome resistance wire, or an etched Inconel foil circuit, vulcanised between two sheets of fibreglass-reinforced silicone rubber. The construction is about 1.2 to 2 mm thick, conforms to a curved surface, and holds its dielectric strength from -50 °C up to 200 °C continuously. On a cell block the watt density is kept deliberately low: the object is to raise the whole pack a few degrees evenly, not to warm one face fast, and a hot spot against a cell is worse than no heater at all.

The heat leaves through the bonded face. Everything that is not in contact with the load radiates and convects from the back of the heater instead, which at these thicknesses is a poor path — so an air gap under part of the outline is not a small loss of efficiency, it is a hot spot at that spot.

Elementnichrome wire or etched Inconel foil
Insulation systemfibreglass-reinforced silicone rubber
Total thickness1.2 mm
Maximum size, one piece500 x 1000 mm (one piece)
Continuous working temperature200 °C

The continuous limit of 200 °C is set by fibreglass-reinforced silicone rubber. The element alloy would run far hotter; it is never the element that decides.

Which Temperature Is Being Held

Three temperatures matter and they are not the same number: the element temperature, the temperature of the surface being heated, and the ambient. A heater rated for a continuous working temperature is rated at the element — the hottest point in the assembly, and the one nothing on the outside is measuring.

The gap between element and surface is the thermal path. Bonded to metal it may be a few degrees; across an air gap, a void in the adhesive or a dry clamped joint it can be tens of degrees, and every one of them appears at the element rather than at the load.

Which is why sensor position is a drawing item. A sensor laminated into the heater protects the heater; a sensor on the load controls the load. Assemblies that have to do both carry two: a control sensor where the process is, and a limit device against the element.

Uniformity across the heated face is u00b13 u00b0C across the heated face at steady state, achieved by varying the element pitch across the outline rather than by adding wattage — the cold corner of a heated plate is a layout problem, and more power makes the hot part hotter.

Watt Density: the Two Figures

Watt density, not wattage, is what the construction is limited by. 0.3 W/cm² unbonded and 2 W/cm² bonded to metal are the limits for this build — so if the wattage is fixed by the duty, the area is what has to move.

Where the required power will not fit into the available area at the free-air figure, the answer is a better thermal path rather than a thinner margin: bond the whole face down, or add a spreader plate. On 150 cm² the difference is roughly 45 W against 3 W, which is usually the whole argument.

Control and Protection

This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.

The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.

Sensors can be built into the part: NTC thermistor, PT100 or PT1000 RTD, or a K-type thermocouple, fitted under the same insulation and tested with the heater as one assembly. A sensor laminated into the heater reads the heater; a sensor on the load reads the load. Both are legitimate, and the drawing has to say which is wanted.

Where This Construction Is the Wrong Answer

  • Do not plan on running above 200 °C. That ceiling belongs to the insulation system, not to the element alloy, and it is not a figure that derating extends — past it the insulation degrades and the dielectric strength goes with it.
  • Do not treat silicone as a moisture barrier. It is permeable to water vapour and is attacked by concentrated acids and some solvents; where the heater is immersed or splashed continuously, the sealing is a design item and not a property of the material.

Other Constructions That Hold 80 °C to 120 °C

Constructions in this catalogue that will hold 80 °c to 120 °c continuously:

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • An outline drawing, or a sketch with dimensions: overall size, holes, cut-outs, radii and the lead exit position.
  • The supply voltage, and whether it is AC or DC. The element is wound for one voltage; it is not a switchable range.
  • The power required, or — better — the temperature to be reached and the mass or flow it has to be reached in. Given the second, the wattage can be calculated instead of guessed.
  • What the heater is attached to, and how. This is what decides which watt density figure applies, and it is the question a quotation cannot proceed without.
  • The ambient, and the lowest temperature the assembly must start from. A heater sized for a 20 °C start is undersized for a -30 °C one.
  • Duty cycle: continuous, intermittent, or a warm-up to a deadline. Time to temperature is a specification, not a by-product.
  • Sensor and protection: which sensor, where it goes, and which limit device is fitted in series with the element.
  • The certification the end product is built to, named on the enquiry rather than after approval.
  • Quantity and target price, because the construction that is right for fifty pieces is often not the one that is right for fifty thousand.
  • Whether adhesive backing is wanted, and what surface it goes onto — a low-energy plastic needs a different adhesive from bare aluminium.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

Battery Pack Silicone Heaters — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
ConstructionNichrome resistance wire wound on a fibreglass carrier, or etched Inconel foil, vulcanised between two sheets of fibreglass-reinforced silicone rubberDecided at quotation from the outline and the wattage
Insulation systemFibreglass-reinforced silicone rubber, both facesThis is what sets the temperature limit, not the element
Total thickness1.2 mmNominal, before adhesive; add 0.2 mm for PSA backing
Minimum size25 x 25 mmBelow this the element cannot be routed with a safe edge margin
Maximum size, one piece500 x 1000 mm (one piece)Larger areas are supplied as tiled zones with separate circuits
Dimensional toleranceu00b11.5 mm on dimensions up to 300 mm, u00b10.5%% aboveOn the die-cut outline; hole positions are held tighter
Supply voltage5 V DC to 240 V AC, wound to orderWound to the ordered voltage u2014 it is not a switchable range
Resistance toleranceu00b110% standard, u00b15% on requestMeasured at 20 u00b0C; hot resistance differs with the element alloy
Watt density, free air0.3 W/cmu00b2 typical, 0.4 W/cmu00b2 maximumNothing conducting heat away u2014 the honest figure for an unbonded heater
Watt density, bonded to heat sink2.0 W/cmu00b2 maximumOnly valid with full-area contact to metal; specifying at this figure and running in free air destroys the heater
Continuous working temperature-50 u00b0C to +200 u00b0C continuous (+240 u00b0C intermittent)Of the heater itself, measured at the element, not the ambient
Dielectric strength2500 V AC, 1 minuteOne minute, element to any exposed surface, no breakdown
Insulation resistancegreater than 100 Mu03a9At 500 V DC, measured after the dielectric test
Lead wireSilicone-insulated stranded copper, 22 AWG to 16 AWG, PTFE where the exit is hotLength, gauge and termination to your drawing
AttachmentFree, 3M 468MP or 9077 PSA backing, vulcanised to the part, or mechanically clampedAdhesive-backed heaters need continuous contact pressure while curing
Sensor and control optionsNTC 10K B3950, PT100/PT1000, K-type thermocouple, KSD9700 bimetal thermostat, thermal cutoffFitted under the same insulation and tested as one assembly
Certifications availableUL 499 construction, IEC/EN 60335, UL 94 V-0 materials, RoHS, REACH, CEConstructions are built to these; the certificate covers the construction, not every outline
Typical dutyPack pre-conditioning from -30 u00b0C to +5 u00b0C before chargeA lithium cell must not be charged below 0 u00b0C u2014 this is the heater that prevents it
Uniformityu00b13 u00b0C across the heated face at steady stateAchieved by varying the element pitch, not by adding wattage

Capability figures are this factory's process limits for the construction described. Watt density limits follow the published maxima for fibreglass-reinforced silicone rubber heaters (to about 12 W/cm² bonded to a heat sink, far less in free air); continuous temperature limits are those of the silicone insulation system, not of the element alloy.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.

Build the Drawing

The panel above checks whether a size and a wattage can be built. This is the drawing itself: set the outline, route the heating track, place the lead wires, terminals, connector and temperature sensor, working in silicone rubber, and turn the model to look at it. When it is right, export the 2D drawing as a PDF or a DXF and send it with your enquiry — a drawing is what a quotation for battery pack silicone heaters is actually written from.

HEATING FILM DRAWING
Silicone Rubber Heater

Draw the outline, route the heating track, place the lead exits, terminals and sensor, dimension it, then export a PDF or a DXF and send it with your enquiry. Nothing here is a stock part and nothing you draw commits you to anything.

CMD

Want to compare constructions before you draw? Open the full builder, where every film family is selectable in one place.

Our facility

Held in production, not just on paper

The limits above are the ones our own lamination press, die and test lines actually hold, and every unit is tested rather than a sample. A figure is only worth quoting if it survives the process that produces it.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (UL 499 / IEC 60335 / RoHS)

ParameterSpecificationLimit / note
ConstructionNichrome resistance wire wound on a fibreglass carrier, or etched Inconel foil, vulcanised between two sheets of fibreglass-reinforced silicone rubberDecided at quotation from the outline and the wattage
Insulation systemFibreglass-reinforced silicone rubber, both facesThis is what sets the temperature limit, not the element
Total thickness1.2 mmNominal, before adhesive; add 0.2 mm for PSA backing
Minimum size25 x 25 mmBelow this the element cannot be routed with a safe edge margin
Maximum size, one piece500 x 1000 mm (one piece)Larger areas are supplied as tiled zones with separate circuits
Dimensional toleranceu00b11.5 mm on dimensions up to 300 mm, u00b10.5%% aboveOn the die-cut outline; hole positions are held tighter
Supply voltage5 V DC to 240 V AC, wound to orderWound to the ordered voltage u2014 it is not a switchable range
Resistance toleranceu00b110% standard, u00b15% on requestMeasured at 20 u00b0C; hot resistance differs with the element alloy
Watt density, free air0.3 W/cmu00b2 typical, 0.4 W/cmu00b2 maximumNothing conducting heat away u2014 the honest figure for an unbonded heater
Watt density, bonded to heat sink2.0 W/cmu00b2 maximumOnly valid with full-area contact to metal; specifying at this figure and running in free air destroys the heater
Continuous working temperature-50 u00b0C to +200 u00b0C continuous (+240 u00b0C intermittent)Of the heater itself, measured at the element, not the ambient
Dielectric strength2500 V AC, 1 minuteOne minute, element to any exposed surface, no breakdown
Insulation resistancegreater than 100 Mu03a9At 500 V DC, measured after the dielectric test
Lead wireSilicone-insulated stranded copper, 22 AWG to 16 AWG, PTFE where the exit is hotLength, gauge and termination to your drawing
AttachmentFree, 3M 468MP or 9077 PSA backing, vulcanised to the part, or mechanically clampedAdhesive-backed heaters need continuous contact pressure while curing
Sensor and control optionsNTC 10K B3950, PT100/PT1000, K-type thermocouple, KSD9700 bimetal thermostat, thermal cutoffFitted under the same insulation and tested as one assembly
Certifications availableUL 499 construction, IEC/EN 60335, UL 94 V-0 materials, RoHS, REACH, CEConstructions are built to these; the certificate covers the construction, not every outline
Typical dutyPack pre-conditioning from -30 u00b0C to +5 u00b0C before chargeA lithium cell must not be charged below 0 u00b0C u2014 this is the heater that prevents it
Uniformityu00b13 u00b0C across the heated face at steady stateAchieved by varying the element pitch, not by adding wattage

Video: Battery Pack Silicone Heaters for 80-120 °C

Do Convertible Modes Actually Work & Save Power? Samsung WindFree AC Power Consumption Test

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

What watt density can battery pack silicone heaters run at?

0.3 W/cm² with nothing conducting the heat away, and 2 W/cm² bonded over its whole area to metal. The two figures describe two different installations, not a range to choose from: a heater specified at 2 W/cm² and then run in free air reaches its insulation limit within minutes.

What is the maximum temperature of battery pack silicone heaters?

200 °C continuous, measured at the element. The limit belongs to fibreglass-reinforced silicone rubber and not to the element alloy, so it is not a figure that can be extended by derating the power.

Does this heater need a thermostat?

Yes. It has no mechanism for limiting its own temperature — with the load removed or the control loop failed it keeps producing the same power — so the design needs a controller with a sensor to hold the set point and, separately, a bimetal thermostat or a one-shot thermal cutoff in series with the element as protection.

Is there a part number I can order?

No — these are made to your drawing, so a part number would describe something that was never built. A quotation needs the outline, the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. The table on this page is what the factory can hold, not a stock list.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.