Skip to content
Temperature Sensing & Control · IEC 60730 / IEC 60335 / RoHS

IEC 60730 NTC Thermistor Sensors

What IEC 60730 fixes, what it deliberately leaves to another document, and how it is evidenced on a heater built to a customer drawing.

Automatic electrical controls: the safety standard for thermostats, thermal cutoffs and temperature controllers, including the type 1 / type 2 action classification and the number of cycles a control is tested to.

Standard
IEC 60730
What it does not cover
A control certified to it is a safe control; it does not follow that a heater fitted with one is a certified appliance.
Construction
NTC Thermistor Sensors
Built and tested to
IEC 60730 / IEC 60335 / RoHS
Continuous temperature limit
200 °C continuous

A construction is built and tested to a standard. A heater made to your outline has no certified part number of its own, so the approval sits with the end product and with the file you hold — what this factory supplies is the construction, the materials and the test records that let that file be assembled.

NTC Thermistor Sensors — the construction this guide is about

Certification page for ntc thermistor sensors under IEC 60730. Automatic electrical controls: the safety standard for thermostats, thermal cutoffs and temperature controllers, including the type 1 / type 2 action classification and the number of cycles a control is tested to.

IEC 60730 — Scope

Automatic electrical controls: the safety standard for thermostats, thermal cutoffs and temperature controllers, including the type 1 / type 2 action classification and the number of cycles a control is tested to.

What IEC 60730 Does Not Cover

A control certified to it is a safe control; it does not follow that a heater fitted with one is a certified appliance.

This is the division of labour to carry away from any heating standard: safety standards decide whether the part can hurt somebody, and say nothing about whether it holds a temperature, lasts five years or matches the last batch. Performance is a specification you write; safety is one the standard writes.

How a Made-to-Drawing Heater Is Certified

A construction is built and tested to a standard. The insulation system, the creepage and clearance distances, the earthing, the lead anchorage, the temperature under fault and the marking are what the test covers — and all of those are properties of the construction rather than of the outline it is die-cut to.

So a custom outline does not have a certificate of its own, and no supplier can honestly hand you one. What is available is the construction file: the standard the build is tested to, the materials list with their own ratings, and the test reports. That is what an approvals engineer needs, and it is what the end product's own certification is built on.

The practical consequence: name IEC 60730 on the enquiry, not after approval. A construction chosen for cost and then asked to pass a standard afterwards usually has to be rebuilt, because the insulation thickness, the creepage distances and the lead anchorage are decided at design time and are not adjustable later.

What an NTC Thermistor Sensors Is

The 10K B3950 thermistor is the default sensor on a low voltage heater: cheap, sensitive, and readable by any microcontroller with one resistor.

A sensing component, specified by its tolerance class, its usable range and its response time. It has no watt density and no outline; it is fitted to a heater or to the surface the heater is warming, and where it is fitted decides what the control loop is actually controlling.

The heat leaves through whatever the component is clamped or bonded to; a sensing component adds no heat of its own and simply has to be in thermal contact with the thing it is reporting on.

Total thicknessComponent
Maximum size, one pieceComponent
Continuous working temperature200 °C

The continuous limit of 200 °C is set by the insulation system. The element alloy would run far hotter; it is never the element that decides.

Other Constructions Built to IEC 60730

Control and Protection

This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.

The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.

Attachment and Thermal Contact

A sensing component is fitted where it will read the temperature that matters: against the element for a limit device, against the load for a control device. The two positions give different numbers, and choosing the wrong one is the commonest reason a correctly built loop holds the wrong temperature.

A sensor reads its own junction, not the surface it is near. Bed it in thermal compound, clamp it, or pot it into the assembly: an air gap of a tenth of a millimetre between a thermistor and the plate it is supposed to be measuring is worth several degrees of error, and it is an error the controller cannot see.

Leads and Terminations

Termination is specified on the drawing: lead length, gauge, insulation and the connector or tag at the end of it.

The lead exit is a thermal discontinuity as well as an electrical one. The joint between a fine element and a stranded lead is the hottest point of many heaters, so it is kept out of the highest watt density zone, strain relieved, and — where the exit sits in a hot area — insulated in PTFE rather than in silicone.

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • The temperature to be sensed or switched, and the tolerance the application actually needs.
  • Where the component sits — against the element, in the potting, on the load, or in the airflow.
  • The electrical duty: for a switching device, the voltage, the current and whether the load is AC or DC.
  • Lead length, insulation and termination, and whether the component is fitted by us into a heater assembly or supplied loose.
  • The standard the end product is certified to, so the component chosen is one that fits inside that approval.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

NTC Thermistor Sensors — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
TypeNegative temperature coefficient thermistorResistance falls as temperature rises, steeply
Standard part10 ku03a9 at 25 u00b0C, B25/50 = 3950 KThe value nearly every controller expects by default
Other values5 ku03a9, 50 ku03a9, 100 ku03a9; B values 3435 K to 4100 KChosen to match the controller, not the heater
Toleranceu00b11% resistance, u00b11% B valueu00b10.5 u00b0C interchangeable parts available
Temperature range-40 u00b0C to +200 u00b0C depending on encapsulationEpoxy bead to +125 u00b0C, glass bead to +200 u00b0C
Response time1 to 10 seconds depending on mass and mountingMounting dominates: a sensor in air reads air
EncapsulationEpoxy bead, glass bead, or laminated into the heaterLaminated is what makes it read the element
LeadsPTFE or silicone insulated, to your length and termination

Figures are the published tolerance and rating bands of the standard sensor and control components fitted to these heaters. Sensor tolerance classes follow IEC 60751 for RTDs and IEC 60584 for thermocouples; thermostat and thermal cutoff ratings are the component manufacturers' own.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.
Our facility

Where these heaters are actually made

Circuit layout, element preparation, lamination and vulcanising, die cutting and lead attachment all happen under one roof, so a watt density limit and a temperature ceiling are set by processes we control and can evidence, not by whichever supplier had stock.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (IEC 60730 / IEC 60335 / RoHS)

ParameterSpecificationLimit / note
TypeNegative temperature coefficient thermistorResistance falls as temperature rises, steeply
Standard part10 ku03a9 at 25 u00b0C, B25/50 = 3950 KThe value nearly every controller expects by default
Other values5 ku03a9, 50 ku03a9, 100 ku03a9; B values 3435 K to 4100 KChosen to match the controller, not the heater
Toleranceu00b11% resistance, u00b11% B valueu00b10.5 u00b0C interchangeable parts available
Temperature range-40 u00b0C to +200 u00b0C depending on encapsulationEpoxy bead to +125 u00b0C, glass bead to +200 u00b0C
Response time1 to 10 seconds depending on mass and mountingMounting dominates: a sensor in air reads air
EncapsulationEpoxy bead, glass bead, or laminated into the heaterLaminated is what makes it read the element
LeadsPTFE or silicone insulated, to your length and termination

Video: IEC 60730 NTC Thermistor Sensors

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

What is the maximum temperature of ntc thermistor sensors?

200 °C continuous, measured at the element. The limit belongs to the insulation system and not to the element alloy, so it is not a figure that can be extended by derating the power.

Does this heater need a thermostat?

Yes. It has no mechanism for limiting its own temperature — with the load removed or the control loop failed it keeps producing the same power — so the design needs a controller with a sensor to hold the set point and, separately, a bimetal thermostat or a one-shot thermal cutoff in series with the element as protection.

How large can one piece be?

Component in a single piece. Larger areas are supplied as tiled zones with separate circuits, which is usually better engineering anyway: separate zones can be controlled separately, and a large single circuit has to carry the whole current at one lead exit.

Is this heater IEC 60730 approved?

The construction is built and tested to IEC 60730; the outline is yours, and a made-to-drawing outline does not carry a certificate of its own. What is available is the construction file — the standard the build is tested to, the material ratings and the test reports — which is what your own product approval is built on.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.