Temperature Sensing & Control · IEC 60730 / IEC 60335 / RoHS

5 V DC NTC Thermistor Sensors

How this construction is wound for 5 V DC, with the temperature the insulation holds continuously and the control and cut-out the design has to carry.

5 V DC NTC Thermistor Sensors: continuous limit 200 °C continuous, total thickness Component, maximum single-piece outline Component. At 5 V every 100 W of element power draws about 20 A, so the lead gauge, the connector and the switching device are sized from the wattage before anything else is decided.

Supply
5 V DC
Continuous temperature limit
200 °C continuous
Total thickness
Component
Maximum outline, one piece
Component

The element is wound to a resistance, so power follows the square of the supply: the same part on 240 V instead of 220 V makes about 19% more heat. The supply voltage is a drawing item, not a preference, and a heater wound for one voltage is not derated onto another.

NTC Thermistor Sensors — the construction this guide is about

NTC Thermistor Sensors wound for 5 V DC. The supply decides the element: 10 W at this voltage is 2.5 Ω, and the same 10 W at a tenth of the voltage would be a hundredth of the resistance in a conductor ten times heavier. This page covers the circuit, the isolation, the switching and what the construction can be built to at this supply.

The Element at 5 V DC

Two equations do all the work: P = V²/R and I = P/V. At 5 V DC, 10 W is 2.5 Ω and 2 A.

Worked example10 W at 5 V DC
Element resistance, R = V²/P2.5 Ω
Current, I = P/V2 A

The span matters more than the example. At 5 V DC a 20 W element is 1 Ω and a 500 W element is 0.1 Ω — a factor of twenty-five in resistance, met by changing the conductor cross-section and the length of the path, both of which are constrained by the outline.

At low voltage the difficulty is current, not insulation. 2 A wants 16 AWG rather than 22 AWG lead wire: 16 AWG is about 13 mΩ per metre, so a 2 m pair adds roughly 0.053 Ω to the circuit and dissipates 0.2 W in the leads instead of in the heater. Contact resistance at a crimp or a connector sits in series with the element in exactly the same way, and on a 1 Ω element a 20 mΩ joint is 2% of the power lost where nobody is looking for it.

The design consequence is that lead length and termination are part of the specification at low voltage. On a 5 V element the leads and the connector can account for a tenth of the total resistance, which shows up directly as a heater that never reaches temperature.

Isolation, Earthing and Safety Class

5 V DC is inside the safety extra-low voltage band, so the supply itself is not a shock hazard and the heater does not need a protective earth or double insulation on that account. The low voltage directive does not apply below 75 V DC.

What still applies is everything else: the element is at the far end of a circuit that can deliver a large current, so short-circuit protection, conductor sizing and the thermal cutoff are unchanged. Low voltage removes the shock risk, not the fire risk.

What an NTC Thermistor Sensors Is

The 10K B3950 thermistor is the default sensor on a low voltage heater: cheap, sensitive, and readable by any microcontroller with one resistor.

A sensing component, specified by its tolerance class, its usable range and its response time. It has no watt density and no outline; it is fitted to a heater or to the surface the heater is warming, and where it is fitted decides what the control loop is actually controlling.

The heat leaves through whatever the component is clamped or bonded to; a sensing component adds no heat of its own and simply has to be in thermal contact with the thing it is reporting on.

Total thicknessComponent
Maximum size, one pieceComponent
Continuous working temperature200 °C

The continuous limit of 200 °C is set by the insulation system. The element alloy would run far hotter; it is never the element that decides.

Switching a DC Element

DC has no zero crossing, so a mechanical contact has to break the arc itself. A relay rated 10 A at 250 V AC may be rated 1 A or less at 30 V DC for exactly that reason, and using the AC number is how contacts weld closed — with a resistive heater on the other side, a welded contact is a heater that cannot be turned off. At 5 V DC and 2 A, use a MOSFET, a DC-rated solid state relay or a contactor with a DC rating.

PWM is the natural control method on DC, and a low frequency is right: a few hertz to a few hundred hertz is plenty for something with the thermal time constant of a heater, and it keeps the switching losses and the emissions down. There is nothing to gain from switching a thermal load at 20 kHz.

One DC-specific failure mode is worth naming: a continuous DC bias across a damp printed circuit drives electrochemical migration between adjacent tracks. It is why a silver-ink element in a humid installation is specified with a conformal barrier or reversed periodically, and why carbon ink is still used where the geometry allows it.

Attachment and Thermal Contact

A sensing component is fitted where it will read the temperature that matters: against the element for a limit device, against the load for a control device. The two positions give different numbers, and choosing the wrong one is the commonest reason a correctly built loop holds the wrong temperature.

A sensor reads its own junction, not the surface it is near. Bed it in thermal compound, clamp it, or pot it into the assembly: an air gap of a tenth of a millimetre between a thermistor and the plate it is supposed to be measuring is worth several degrees of error, and it is an error the controller cannot see.

Leads and Terminations

Termination is specified on the drawing: lead length, gauge, insulation and the connector or tag at the end of it.

The lead exit is a thermal discontinuity as well as an electrical one. The joint between a fine element and a stranded lead is the hottest point of many heaters, so it is kept out of the highest watt density zone, strain relieved, and — where the exit sits in a hot area — insulated in PTFE rather than in silicone.

Control and Protection

This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.

The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.

How This Construction Fails

  • Loss of the control loop. An open-circuit sensor, a welded relay contact or a controller in manual leaves the element at full power with nothing watching it — the case the series thermal cutoff exists for, and the reason it must not be omitted to save a part.
  • Measuring the wrong thing. A sensor in the air near a heated plate reports the air, and the loop holds the air where the specification wanted the plate. Nothing in the instrument can detect this.

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • The temperature to be sensed or switched, and the tolerance the application actually needs.
  • Where the component sits — against the element, in the potting, on the load, or in the airflow.
  • The electrical duty: for a switching device, the voltage, the current and whether the load is AC or DC.
  • Lead length, insulation and termination, and whether the component is fitted by us into a heater assembly or supplied loose.
  • The standard the end product is certified to, so the component chosen is one that fits inside that approval.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

NTC Thermistor Sensors — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
TypeNegative temperature coefficient thermistorResistance falls as temperature rises, steeply
Standard part10 ku03a9 at 25 u00b0C, B25/50 = 3950 KThe value nearly every controller expects by default
Other values5 ku03a9, 50 ku03a9, 100 ku03a9; B values 3435 K to 4100 KChosen to match the controller, not the heater
Toleranceu00b11% resistance, u00b11% B valueu00b10.5 u00b0C interchangeable parts available
Temperature range-40 u00b0C to +200 u00b0C depending on encapsulationEpoxy bead to +125 u00b0C, glass bead to +200 u00b0C
Response time1 to 10 seconds depending on mass and mountingMounting dominates: a sensor in air reads air
EncapsulationEpoxy bead, glass bead, or laminated into the heaterLaminated is what makes it read the element
LeadsPTFE or silicone insulated, to your length and termination

Figures are the published tolerance and rating bands of the standard sensor and control components fitted to these heaters. Sensor tolerance classes follow IEC 60751 for RTDs and IEC 60584 for thermocouples; thermostat and thermal cutoff ratings are the component manufacturers' own.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.
Our facility

The numbers come off our own machines

Every unit is measured for resistance, held at its dielectric test voltage for a minute, and measured again for insulation resistance. Sample units from each lot are run under power and imaged. That is why the values on this page are quotable rather than indicative.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (IEC 60730 / IEC 60335 / RoHS)

ParameterSpecificationLimit / note
TypeNegative temperature coefficient thermistorResistance falls as temperature rises, steeply
Standard part10 ku03a9 at 25 u00b0C, B25/50 = 3950 KThe value nearly every controller expects by default
Other values5 ku03a9, 50 ku03a9, 100 ku03a9; B values 3435 K to 4100 KChosen to match the controller, not the heater
Toleranceu00b11% resistance, u00b11% B valueu00b10.5 u00b0C interchangeable parts available
Temperature range-40 u00b0C to +200 u00b0C depending on encapsulationEpoxy bead to +125 u00b0C, glass bead to +200 u00b0C
Response time1 to 10 seconds depending on mass and mountingMounting dominates: a sensor in air reads air
EncapsulationEpoxy bead, glass bead, or laminated into the heaterLaminated is what makes it read the element
LeadsPTFE or silicone insulated, to your length and termination

Video: 5 V DC NTC Thermistor Sensors

Vishay Resistors: NTC Lug Thermistors; Surface Temperature Sensors

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

How much current does a heater draw at 5 V DC?

I = P/V. At 5 V DC a 100 W heater draws 20 A and its element is 0.3 Ω; a 500 W heater draws 100 A and is 0.1 Ω. The current is what sizes the lead wire, the connector and the switching device, and at low voltage it is the whole design problem.

Can a 5 V DC heater be run on another voltage?

No. The element is wound for one voltage at manufacture. Power goes with the square of the supply, so at half the voltage it makes a quarter of the power and at twice the voltage it makes four times the power — which is how a heater is destroyed on its first run.

Is 5 V DC safe to touch?

5 V DC is within safety extra-low voltage, so the supply itself is not a shock hazard and no protective earth is required on that account. The fire risk is unchanged: the element still produces its full power into a fault, so fusing, conductor sizing and the thermal cutoff are exactly as important as at mains voltage.

What is the maximum temperature of ntc thermistor sensors?

200 °C continuous, measured at the element. The limit belongs to the insulation system and not to the element alloy, so it is not a figure that can be extended by derating the power.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.