Skip to content
Epoxy Heating Plates · UL 499 / IEC 60335 / RoHS

Epoxy Encapsulated Plate Heaters for Up to 80 °C

Which insulation systems hold Up to 80 °C continuously, what this construction is rated to, and the control and cut-out that hold the surface there.

Epoxy Encapsulated Plate Heaters are rated 150 °C continuous, a limit set by the thermally conductive filled epoxy, which covers Up to 80 °C. Comfort and condensation control: seat heating, mirror demisting, enclosure anti-condensation, battery pre-conditioning. Almost any construction reaches it, so the choice is decided by cost and thickness rather than by the temperature.

Working band
Up to 80 °C
Continuous limit, this construction
150 °C
Set by
Thermally conductive filled epoxy
Watt density
0.5 W/cm² free air, 3 W/cm² bonded
Total thickness
6 mm to 15 mm
Maximum outline, one piece
400 x 600 mm

The band is the temperature the heated surface has to hold, not the temperature the element reaches. The element always runs hotter, by an amount the watt density and the thermal path decide, so the cut-out is set against the element and not against the load.

Epoxy Encapsulated Plate Heaters — the construction this guide is about

Epoxy Encapsulated Plate Heaters in the up to 80 °c band. Comfort and condensation control: seat heating, mirror demisting, enclosure anti-condensation, battery pre-conditioning. Almost any construction reaches it, so the choice is decided by cost and thickness rather than by the temperature. The construction is rated 150 °C continuous, so this band sits inside its ceiling — and where a band sits relative to the ceiling is the whole of the selection argument.

What the Up to 80 °C Band Requires

Comfort and condensation control: seat heating, mirror demisting, enclosure anti-condensation, battery pre-conditioning. Almost any construction reaches it, so the choice is decided by cost and thickness rather than by the temperature.

BandUp to 80 °C
This construction, continuous150 °C
Limited bythermally conductive filled epoxy

The band sits comfortably inside the 150 °C ceiling, which is where a heater should be specified: the margin between the working temperature and the insulation limit is what absorbs a poor thermal path, a warm ambient and a control overshoot without shortening the life of the part.

Why the Boundary Is Where It Is

80 °C is not a material boundary at all — every construction here passes through it — so the choice inside this band is decided by cost, thickness and area rather than by temperature. That is why printed film competes here and nowhere above it.

The engineering in this band is uniformity and control, not survival: comfort heating, condensation control and battery pre-conditioning all care about holding a few degrees evenly over a large area, which is a watt density and layout problem.

What an Epoxy Encapsulated Plate Heaters Is

A flat, rigid, sealed heating plate: element potted in filled epoxy on aluminium, for conduction heating where a flexible heater will not stay flat.

A resistance wire or foil element vacuum potted in thermally conductive filled epoxy against an aluminium or steel plate. Rigid, flat, sealed, and thermally bonded to its own plate so the heat leaves the element through metal rather than through air.

The plate is the thermal path: the element is potted against it, so the metal spreads the heat before the load ever sees it. That is what buys uniformity, and it is also what makes the assembly slow — a bolted plate takes minutes to reach steady state where a film takes seconds.

Elementresistance wire or foil, vacuum potted
Insulation systemthermally conductive filled epoxy
Total thickness6 mm to 15 mm
Maximum size, one piece400 x 600 mm
Continuous working temperature150 °C

The continuous limit of 150 °C is set by thermally conductive filled epoxy. The element alloy would run far hotter; it is never the element that decides.

Which Temperature Is Being Held

Three temperatures matter and they are not the same number: the element temperature, the temperature of the surface being heated, and the ambient. A heater rated for a continuous working temperature is rated at the element — the hottest point in the assembly, and the one nothing on the outside is measuring.

The gap between element and surface is the thermal path. Bonded to metal it may be a few degrees; across an air gap, a void in the adhesive or a dry clamped joint it can be tens of degrees, and every one of them appears at the element rather than at the load.

Which is why sensor position is a drawing item. A sensor laminated into the heater protects the heater; a sensor on the load controls the load. Assemblies that have to do both carry two: a control sensor where the process is, and a limit device against the element.

Attachment and Thermal Contact

The plate is drilled or tapped to your drawing and bolts to the machine. The heated face has to sit flat against the load; where it cannot, a thermal interface pad is worth more than extra wattage.

Allow for expansion. An aluminium plate 400 mm long grows about 1 mm between 20 °C and 130 °C, so a plate bolted rigidly at both ends will bow, and the bow lifts the middle of the heated face away from the load.

From the capability table: Tapped holes, clearance holes, studs or bonded.

The joint between the heated surface and the load carries every watt the element makes. Fill it: an interface pad, a thin film of thermal grease or a bonded assembly. Two dry surfaces bolted together are a thermal resistance, and that resistance appears as element temperature.

Control and Protection

This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.

The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.

The limit that matters is the epoxy's, at 150 °C, and it is reached at the element long before the plate face reads anything alarming. Put the limit device in the potting against the element, not on the outside of the plate.

Sensors can be built into the part: NTC thermistor, PT100 or PT1000 RTD, or a K-type thermocouple, fitted under the same insulation and tested with the heater as one assembly. A sensor laminated into the heater reads the heater; a sensor on the load reads the load. Both are legitimate, and the drawing has to say which is wanted.

How This Construction Fails

  • Run at the bonded watt density in free air. The insulation reaches its limit within minutes and the element burns through where the local density is highest. Specify at 3 W/cm² only where the heater is genuinely bonded to metal over its whole area; unbonded, the figure is 0.5 W/cm².
  • Loss of the control loop. An open-circuit sensor, a welded relay contact or a controller in manual leaves the element at full power with nothing watching it — the case the series thermal cutoff exists for, and the reason it must not be omitted to save a part.
  • Overheating the encapsulant. The epoxy is the weakest link at 150 °C and it fails from the inside, where nothing is measuring; the plate face can look reasonable while the potting against the element is already cooking.

Other Constructions That Hold Up to 80 °C

Constructions in this catalogue that will hold up to 80 °c continuously:

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • An outline drawing, or a sketch with dimensions: overall size, holes, cut-outs, radii and the lead exit position.
  • The supply voltage, and whether it is AC or DC. The element is wound for one voltage; it is not a switchable range.
  • The power required, or — better — the temperature to be reached and the mass or flow it has to be reached in. Given the second, the wattage can be calculated instead of guessed.
  • What the heater is attached to, and how. This is what decides which watt density figure applies, and it is the question a quotation cannot proceed without.
  • The ambient, and the lowest temperature the assembly must start from. A heater sized for a 20 °C start is undersized for a -30 °C one.
  • Duty cycle: continuous, intermittent, or a warm-up to a deadline. Time to temperature is a specification, not a by-product.
  • Sensor and protection: which sensor, where it goes, and which limit device is fitted in series with the element.
  • The certification the end product is built to, named on the enquiry rather than after approval.
  • Quantity and target price, because the construction that is right for fifty pieces is often not the one that is right for fifty thousand.
  • The plate material, thickness and mounting hole pattern, and what the plate is bolted to.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

Epoxy Encapsulated Plate Heaters — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
ConstructionResistance wire or foil element potted in thermally conductive filled epoxy on a metal plateCured under vacuum so there are no voids in the heat path
Plate materialAluminium 6061, 3 mm to 10 mmAluminium for spreading, stainless where the chemistry demands it
Total thickness6 mm to 15 mmPlate plus encapsulation
Maximum size, one piece400 x 600 mmLarger plates are built as multiple circuits on one plate
Dimensional toleranceu00b10.5 mm on the plate, u00b11 mm on the encapsulation
Supply voltage24 V, 48 V, 110 V, 220 VWound to order
Resistance toleranceu00b110%At 20 u00b0C
Watt density0.5 W/cmu00b2 typical, 3.0 W/cmu00b2 maximumAgainst a load in contact; free-standing operation runs far lower
Continuous working temperature-40 u00b0C to +150 u00b0CSet by the epoxy, not by the element
Dielectric strength2500 V AC, 1 minuteElement to plate
Insulation resistancegreater than 100 Mu03a9 at 500 V DCAlso after 48 hours humidity conditioning
Ingress protectionIP65 as standard, IP67 with a moulded lead entryThe encapsulation is the seal
MountingTapped holes, clearance holes, studs or bondedMachined into the plate before potting
Sensor optionsNTC, PT100 or thermostat potted into the same plateReads the plate, which is what the load actually sees
Certifications availableUL 499, IEC/EN 60335, RoHS, REACH, CE, IATF 16949Construction level

Capability figures are for resistance elements encapsulated in thermally conductive filled epoxy on a metal plate. The +150 °C continuous limit is a property of the encapsulant, and it is the lowest limit of any construction in this catalog — the element and the plate would both tolerate far more.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.

Build the Drawing

The panel above checks whether a size and a wattage can be built. This is the drawing itself: set the outline, route the heating track, place the lead wires, terminals, connector and temperature sensor, working in custom outline, and turn the model to look at it. When it is right, export the 2D drawing as a PDF or a DXF and send it with your enquiry — a drawing is what a quotation for epoxy encapsulated plate heaters is actually written from.

HEATING FILM DRAWING
Custom / Special-Shaped Heating Film

Draw the outline, route the heating track, place the lead exits, terminals and sensor, dimension it, then export a PDF or a DXF and send it with your enquiry. Nothing here is a stock part and nothing you draw commits you to anything.

CMD

Want to compare constructions before you draw? Open the full builder, where every film family is selectable in one place.

Our facility

Where these heaters are actually made

Circuit layout, element preparation, lamination and vulcanising, die cutting and lead attachment all happen under one roof, so a watt density limit and a temperature ceiling are set by processes we control and can evidence, not by whichever supplier had stock.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (UL 499 / IEC 60335 / RoHS)

ParameterSpecificationLimit / note
ConstructionResistance wire or foil element potted in thermally conductive filled epoxy on a metal plateCured under vacuum so there are no voids in the heat path
Plate materialAluminium 6061, 3 mm to 10 mmAluminium for spreading, stainless where the chemistry demands it
Total thickness6 mm to 15 mmPlate plus encapsulation
Maximum size, one piece400 x 600 mmLarger plates are built as multiple circuits on one plate
Dimensional toleranceu00b10.5 mm on the plate, u00b11 mm on the encapsulation
Supply voltage24 V, 48 V, 110 V, 220 VWound to order
Resistance toleranceu00b110%At 20 u00b0C
Watt density0.5 W/cmu00b2 typical, 3.0 W/cmu00b2 maximumAgainst a load in contact; free-standing operation runs far lower
Continuous working temperature-40 u00b0C to +150 u00b0CSet by the epoxy, not by the element
Dielectric strength2500 V AC, 1 minuteElement to plate
Insulation resistancegreater than 100 Mu03a9 at 500 V DCAlso after 48 hours humidity conditioning
Ingress protectionIP65 as standard, IP67 with a moulded lead entryThe encapsulation is the seal
MountingTapped holes, clearance holes, studs or bondedMachined into the plate before potting
Sensor optionsNTC, PT100 or thermostat potted into the same plateReads the plate, which is what the load actually sees
Certifications availableUL 499, IEC/EN 60335, RoHS, REACH, CE, IATF 16949Construction level

Video: Epoxy Encapsulated Plate Heaters for Up to 80 °C

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

What watt density can epoxy encapsulated plate heaters run at?

0.5 W/cm² with nothing conducting the heat away, and 3 W/cm² bonded over its whole area to metal. The two figures describe two different installations, not a range to choose from: a heater specified at 3 W/cm² and then run in free air reaches its insulation limit within minutes.

What is the maximum temperature of epoxy encapsulated plate heaters?

150 °C continuous, measured at the element. The limit belongs to thermally conductive filled epoxy and not to the element alloy, so it is not a figure that can be extended by derating the power.

Does this heater need a thermostat?

Yes. It has no mechanism for limiting its own temperature — with the load removed or the control loop failed it keeps producing the same power — so the design needs a controller with a sensor to hold the set point and, separately, a bimetal thermostat or a one-shot thermal cutoff in series with the element as protection.

Is there a part number I can order?

No — these are made to your drawing, so a part number would describe something that was never built. A quotation needs the outline, the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. The table on this page is what the factory can hold, not a stock list.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.