Skip to content
Silicone Rubber Heaters · UL 499 / IEC 60335 / RoHS

Battery Formation Silicone Heaters for Up to 80 °C

Which insulation systems hold Up to 80 °C continuously, what this construction is rated to, and the control and cut-out that hold the surface there.

Battery Formation Silicone Heaters are rated 200 °C continuous, a limit set by the fibreglass-reinforced silicone rubber, which covers Up to 80 °C. Comfort and condensation control: seat heating, mirror demisting, enclosure anti-condensation, battery pre-conditioning. Almost any construction reaches it, so the choice is decided by cost and thickness rather than by the temperature.

Working band
Up to 80 °C
Continuous limit, this construction
200 °C
Set by
Fibreglass-reinforced silicone rubber
Watt density
0.6 W/cm² free air, 4 W/cm² bonded
Total thickness
2.0 mm
Maximum outline, one piece
600 x 1200 mm

The band is the temperature the heated surface has to hold, not the temperature the element reaches. The element always runs hotter, by an amount the watt density and the thermal path decide, so the cut-out is set against the element and not against the load.

Battery Formation Silicone Heaters — the construction this guide is about

The up to 80 °c band is a material boundary, not a convention. Comfort and condensation control: seat heating, mirror demisting, enclosure anti-condensation, battery pre-conditioning. Almost any construction reaches it, so the choice is decided by cost and thickness rather than by the temperature. This page covers what that means for battery formation silicone heaters, which is rated to 200 °C continuous.

What the Up to 80 °C Band Requires

Comfort and condensation control: seat heating, mirror demisting, enclosure anti-condensation, battery pre-conditioning. Almost any construction reaches it, so the choice is decided by cost and thickness rather than by the temperature.

BandUp to 80 °C
This construction, continuous200 °C
Limited byfibreglass-reinforced silicone rubber

The band sits comfortably inside the 200 °C ceiling, which is where a heater should be specified: the margin between the working temperature and the insulation limit is what absorbs a poor thermal path, a warm ambient and a control overshoot without shortening the life of the part.

Why the Boundary Is Where It Is

80 °C is not a material boundary at all — every construction here passes through it — so the choice inside this band is decided by cost, thickness and area rather than by temperature. That is why printed film competes here and nowhere above it.

The engineering in this band is uniformity and control, not survival: comfort heating, condensation control and battery pre-conditioning all care about holding a few degrees evenly over a large area, which is a watt density and layout problem.

What a Battery Formation Silicone Heaters Is

Blue silicone platen heaters for cell formation and ageing racks, built flat and uniform so that every cell in the fixture sees the same temperature.

Nichrome resistance wire, or an etched Inconel foil circuit, vulcanised between two sheets of fibreglass-reinforced silicone rubber. The construction is about 1.2 to 2 mm thick, conforms to a curved surface, and holds its dielectric strength from -50 °C up to 200 °C continuously. On a cell block the watt density is kept deliberately low: the object is to raise the whole pack a few degrees evenly, not to warm one face fast, and a hot spot against a cell is worse than no heater at all.

The heat leaves through the bonded face. Everything that is not in contact with the load radiates and convects from the back of the heater instead, which at these thicknesses is a poor path — so an air gap under part of the outline is not a small loss of efficiency, it is a hot spot at that spot.

Elementnichrome wire or etched Inconel foil
Insulation systemfibreglass-reinforced silicone rubber
Total thickness2.0 mm
Maximum size, one piece600 x 1200 mm
Continuous working temperature200 °C

The continuous limit of 200 °C is set by fibreglass-reinforced silicone rubber. The element alloy would run far hotter; it is never the element that decides.

Which Temperature Is Being Held

Three temperatures matter and they are not the same number: the element temperature, the temperature of the surface being heated, and the ambient. A heater rated for a continuous working temperature is rated at the element — the hottest point in the assembly, and the one nothing on the outside is measuring.

The gap between element and surface is the thermal path. Bonded to metal it may be a few degrees; across an air gap, a void in the adhesive or a dry clamped joint it can be tens of degrees, and every one of them appears at the element rather than at the load.

Which is why sensor position is a drawing item. A sensor laminated into the heater protects the heater; a sensor on the load controls the load. Assemblies that have to do both carry two: a control sensor where the process is, and a limit device against the element.

Uniformity across the heated face is u00b12 u00b0C across the platen at 45 u00b0C set point, achieved by varying the element pitch across the outline rather than by adding wattage — the cold corner of a heated plate is a layout problem, and more power makes the hot part hotter.

Attachment and Thermal Contact

Attachment options are a factory-applied pressure-sensitive adhesive, vulcanising or bonding to the customer's part, or mechanical clamping with a plate or a strap.

A PSA bond wants a clean, dry, degreased surface, continuous pressure while it wets out, and no trapped air: a bubble under the element is a spot with no thermal path, and it will be the first place the heater fails. Acrylic adhesives reach full strength over 24 to 72 hours, so the assembly is not at its rated watt density the moment it is pressed down.

From the capability table: Free, 3M 468MP or 9077 PSA backing, vulcanised to the part, or mechanically clamped.

The bond line is part of the thermal circuit and should be specified like one. A 0.05 mm acrylic PSA layer conducts roughly 0.2 W/m·K; a filled silicone adhesive is two to five times better, and a bolted joint with an interface pad better again. Whatever is chosen, it has to be continuous — the heater cannot spread heat sideways to cover a gap, and the temperature under a void rises until something in the stack gives way.

Control and Protection

This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.

The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.

Sensors can be built into the part: NTC thermistor, PT100 or PT1000 RTD, or a K-type thermocouple, fitted under the same insulation and tested with the heater as one assembly. A sensor laminated into the heater reads the heater; a sensor on the load reads the load. Both are legitimate, and the drawing has to say which is wanted.

How This Construction Fails

  • Run at the bonded watt density in free air. The insulation reaches its limit within minutes and the element burns through where the local density is highest. Specify at 4 W/cm² only where the heater is genuinely bonded to metal over its whole area; unbonded, the figure is 0.6 W/cm².
  • Voids under the bond. Air trapped during application, a contaminated surface or an adhesive that never reached full cure all produce the same result: a patch with no thermal path, running far above the rest of the heater, which is where the failure starts.
  • Loss of the control loop. An open-circuit sensor, a welded relay contact or a controller in manual leaves the element at full power with nothing watching it — the case the series thermal cutoff exists for, and the reason it must not be omitted to save a part.
  • Mechanical damage at the edge. Silicone is tough but it tears from a cut, and a heater trimmed to fit on assembly has had its edge seal opened; moisture then tracks along the glass carrier to the element.

Where This Construction Is the Wrong Answer

  • Do not plan on running above 200 °C. That ceiling belongs to the insulation system, not to the element alloy, and it is not a figure that derating extends — past it the insulation degrades and the dielectric strength goes with it.
  • Do not treat silicone as a moisture barrier. It is permeable to water vapour and is attacked by concentrated acids and some solvents; where the heater is immersed or splashed continuously, the sealing is a design item and not a property of the material.

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • An outline drawing, or a sketch with dimensions: overall size, holes, cut-outs, radii and the lead exit position.
  • The supply voltage, and whether it is AC or DC. The element is wound for one voltage; it is not a switchable range.
  • The power required, or — better — the temperature to be reached and the mass or flow it has to be reached in. Given the second, the wattage can be calculated instead of guessed.
  • What the heater is attached to, and how. This is what decides which watt density figure applies, and it is the question a quotation cannot proceed without.
  • The ambient, and the lowest temperature the assembly must start from. A heater sized for a 20 °C start is undersized for a -30 °C one.
  • Duty cycle: continuous, intermittent, or a warm-up to a deadline. Time to temperature is a specification, not a by-product.
  • Sensor and protection: which sensor, where it goes, and which limit device is fitted in series with the element.
  • The certification the end product is built to, named on the enquiry rather than after approval.
  • Quantity and target price, because the construction that is right for fifty pieces is often not the one that is right for fifty thousand.
  • Whether adhesive backing is wanted, and what surface it goes onto — a low-energy plastic needs a different adhesive from bare aluminium.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

Battery Formation Silicone Heaters — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
ConstructionNichrome resistance wire wound on a fibreglass carrier, or etched Inconel foil, vulcanised between two sheets of fibreglass-reinforced silicone rubberDecided at quotation from the outline and the wattage
Insulation systemFibreglass-reinforced silicone rubber, both facesThis is what sets the temperature limit, not the element
Total thickness2.0 mmNominal, before adhesive; add 0.2 mm for PSA backing
Minimum size25 x 25 mmBelow this the element cannot be routed with a safe edge margin
Maximum size, one piece600 x 1200 mmLarger areas are supplied as tiled zones with separate circuits
Dimensional toleranceu00b11.5 mm on dimensions up to 300 mm, u00b10.5%% aboveOn the die-cut outline; hole positions are held tighter
Supply voltage5 V DC to 240 V AC, wound to orderWound to the ordered voltage u2014 it is not a switchable range
Resistance toleranceu00b110% standard, u00b15% on requestMeasured at 20 u00b0C; hot resistance differs with the element alloy
Watt density, free air0.6 W/cmu00b2 typical, 0.9 W/cmu00b2 maximumNothing conducting heat away u2014 the honest figure for an unbonded heater
Watt density, bonded to heat sink4.0 W/cmu00b2 maximumOnly valid with full-area contact to metal; specifying at this figure and running in free air destroys the heater
Continuous working temperature-50 u00b0C to +200 u00b0C continuous (+240 u00b0C intermittent)Of the heater itself, measured at the element, not the ambient
Dielectric strength2500 V AC, 1 minuteOne minute, element to any exposed surface, no breakdown
Insulation resistancegreater than 100 Mu03a9At 500 V DC, measured after the dielectric test
Lead wireSilicone-insulated stranded copper, 22 AWG to 16 AWG, PTFE where the exit is hotLength, gauge and termination to your drawing
AttachmentFree, 3M 468MP or 9077 PSA backing, vulcanised to the part, or mechanically clampedAdhesive-backed heaters need continuous contact pressure while curing
Sensor and control optionsNTC 10K B3950, PT100/PT1000, K-type thermocouple, KSD9700 bimetal thermostat, thermal cutoffFitted under the same insulation and tested as one assembly
Certifications availableUL 499 construction, IEC/EN 60335, UL 94 V-0 materials, RoHS, REACH, CEConstructions are built to these; the certificate covers the construction, not every outline
Uniformityu00b12 u00b0C across the platen at 45 u00b0C set pointFormation yield depends on it u2014 a 5 u00b0C spread across a rack shows up as capacity spread
ColourBlue silicone standard; red, black or grey on requestColour is pigment only and changes nothing thermal

Capability figures are this factory's process limits for the construction described. Watt density limits follow the published maxima for fibreglass-reinforced silicone rubber heaters (to about 12 W/cm² bonded to a heat sink, far less in free air); continuous temperature limits are those of the silicone insulation system, not of the element alloy.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.

Build the Drawing

The panel above checks whether a size and a wattage can be built. This is the drawing itself: set the outline, route the heating track, place the lead wires, terminals, connector and temperature sensor, working in silicone rubber, and turn the model to look at it. When it is right, export the 2D drawing as a PDF or a DXF and send it with your enquiry — a drawing is what a quotation for battery formation silicone heaters is actually written from.

HEATING FILM DRAWING
Silicone Rubber Heater

Draw the outline, route the heating track, place the lead exits, terminals and sensor, dimension it, then export a PDF or a DXF and send it with your enquiry. Nothing here is a stock part and nothing you draw commits you to anything.

CMD

Want to compare constructions before you draw? Open the full builder, where every film family is selectable in one place.

Our facility

Where these heaters are actually made

Circuit layout, element preparation, lamination and vulcanising, die cutting and lead attachment all happen under one roof, so a watt density limit and a temperature ceiling are set by processes we control and can evidence, not by whichever supplier had stock.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (UL 499 / IEC 60335 / RoHS)

ParameterSpecificationLimit / note
ConstructionNichrome resistance wire wound on a fibreglass carrier, or etched Inconel foil, vulcanised between two sheets of fibreglass-reinforced silicone rubberDecided at quotation from the outline and the wattage
Insulation systemFibreglass-reinforced silicone rubber, both facesThis is what sets the temperature limit, not the element
Total thickness2.0 mmNominal, before adhesive; add 0.2 mm for PSA backing
Minimum size25 x 25 mmBelow this the element cannot be routed with a safe edge margin
Maximum size, one piece600 x 1200 mmLarger areas are supplied as tiled zones with separate circuits
Dimensional toleranceu00b11.5 mm on dimensions up to 300 mm, u00b10.5%% aboveOn the die-cut outline; hole positions are held tighter
Supply voltage5 V DC to 240 V AC, wound to orderWound to the ordered voltage u2014 it is not a switchable range
Resistance toleranceu00b110% standard, u00b15% on requestMeasured at 20 u00b0C; hot resistance differs with the element alloy
Watt density, free air0.6 W/cmu00b2 typical, 0.9 W/cmu00b2 maximumNothing conducting heat away u2014 the honest figure for an unbonded heater
Watt density, bonded to heat sink4.0 W/cmu00b2 maximumOnly valid with full-area contact to metal; specifying at this figure and running in free air destroys the heater
Continuous working temperature-50 u00b0C to +200 u00b0C continuous (+240 u00b0C intermittent)Of the heater itself, measured at the element, not the ambient
Dielectric strength2500 V AC, 1 minuteOne minute, element to any exposed surface, no breakdown
Insulation resistancegreater than 100 Mu03a9At 500 V DC, measured after the dielectric test
Lead wireSilicone-insulated stranded copper, 22 AWG to 16 AWG, PTFE where the exit is hotLength, gauge and termination to your drawing
AttachmentFree, 3M 468MP or 9077 PSA backing, vulcanised to the part, or mechanically clampedAdhesive-backed heaters need continuous contact pressure while curing
Sensor and control optionsNTC 10K B3950, PT100/PT1000, K-type thermocouple, KSD9700 bimetal thermostat, thermal cutoffFitted under the same insulation and tested as one assembly
Certifications availableUL 499 construction, IEC/EN 60335, UL 94 V-0 materials, RoHS, REACH, CEConstructions are built to these; the certificate covers the construction, not every outline
Uniformityu00b12 u00b0C across the platen at 45 u00b0C set pointFormation yield depends on it u2014 a 5 u00b0C spread across a rack shows up as capacity spread
ColourBlue silicone standard; red, black or grey on requestColour is pigment only and changes nothing thermal

Video: Battery Formation Silicone Heaters for Up to 80 °C

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

Is there a part number I can order?

No — these are made to your drawing, so a part number would describe something that was never built. A quotation needs the outline, the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. The table on this page is what the factory can hold, not a stock list.

How large can one piece be?

600 x 1200 mm in a single piece. Larger areas are supplied as tiled zones with separate circuits, which is usually better engineering anyway: separate zones can be controlled separately, and a large single circuit has to carry the whole current at one lead exit.

Which heaters work at up to 80 °c?

Comfort and condensation control: seat heating, mirror demisting, enclosure anti-condensation, battery pre-conditioning. Almost any construction reaches it, so the choice is decided by cost and thickness rather than by the temperature.

Is the temperature rating the surface temperature or the element temperature?

The element temperature, which is the hottest point in the assembly and the one nothing on the outside is measuring. The surface being heated sits below it by whatever the thermal path costs — a few degrees through a good bond, tens of degrees across a void or a dry clamped joint.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.