Skip to content
Silicone Rubber Heaters · UL 499 / IEC 60335 / RoHS

IEC/EN 60335 Battery Formation Silicone Heaters

What IEC/EN 60335 fixes, what it deliberately leaves to another document, and how it is evidenced on a heater built to a customer drawing.

The international household and similar appliance safety standard, with part 2 sections for specific appliances. The basis of CE marking for most mains heating products.

Standard
IEC/EN 60335
What it does not cover
It does not cover industrial process heaters, which fall under IEC 60519 and the machinery directive instead.
Construction
Battery Formation Silicone Heaters
Built and tested to
UL 499 / IEC 60335 / RoHS
Insulation
Fibreglass-reinforced silicone rubber
Continuous temperature limit
200 °C continuous

A construction is built and tested to a standard. A heater made to your outline has no certified part number of its own, so the approval sits with the end product and with the file you hold — what this factory supplies is the construction, the materials and the test records that let that file be assembled.

Battery Formation Silicone Heaters — the construction this guide is about

Certification page for battery formation silicone heaters under IEC/EN 60335. The international household and similar appliance safety standard, with part 2 sections for specific appliances. The basis of CE marking for most mains heating products.

IEC/EN 60335 — Scope

The international household and similar appliance safety standard, with part 2 sections for specific appliances. The basis of CE marking for most mains heating products.

What IEC/EN 60335 Does Not Cover

It does not cover industrial process heaters, which fall under IEC 60519 and the machinery directive instead.

This is the division of labour to carry away from any heating standard: safety standards decide whether the part can hurt somebody, and say nothing about whether it holds a temperature, lasts five years or matches the last batch. Performance is a specification you write; safety is one the standard writes.

How a Made-to-Drawing Heater Is Certified

A construction is built and tested to a standard. The insulation system, the creepage and clearance distances, the earthing, the lead anchorage, the temperature under fault and the marking are what the test covers — and all of those are properties of the construction rather than of the outline it is die-cut to.

So a custom outline does not have a certificate of its own, and no supplier can honestly hand you one. What is available is the construction file: the standard the build is tested to, the materials list with their own ratings, and the test reports. That is what an approvals engineer needs, and it is what the end product's own certification is built on.

The practical consequence: name IEC/EN 60335 on the enquiry, not after approval. A construction chosen for cost and then asked to pass a standard afterwards usually has to be rebuilt, because the insulation thickness, the creepage distances and the lead anchorage are decided at design time and are not adjustable later.

From the capability table: UL 499 construction, IEC/EN 60335, UL 94 V-0 materials, RoHS, REACH, CE.

What a Battery Formation Silicone Heaters Is

Blue silicone platen heaters for cell formation and ageing racks, built flat and uniform so that every cell in the fixture sees the same temperature.

Nichrome resistance wire, or an etched Inconel foil circuit, vulcanised between two sheets of fibreglass-reinforced silicone rubber. The construction is about 1.2 to 2 mm thick, conforms to a curved surface, and holds its dielectric strength from -50 °C up to 200 °C continuously. On a cell block the watt density is kept deliberately low: the object is to raise the whole pack a few degrees evenly, not to warm one face fast, and a hot spot against a cell is worse than no heater at all.

The heat leaves through the bonded face. Everything that is not in contact with the load radiates and convects from the back of the heater instead, which at these thicknesses is a poor path — so an air gap under part of the outline is not a small loss of efficiency, it is a hot spot at that spot.

Elementnichrome wire or etched Inconel foil
Insulation systemfibreglass-reinforced silicone rubber
Total thickness2.0 mm
Maximum size, one piece600 x 1200 mm
Continuous working temperature200 °C

The continuous limit of 200 °C is set by fibreglass-reinforced silicone rubber. The element alloy would run far hotter; it is never the element that decides.

Other Constructions Built to IEC/EN 60335

Control and Protection

This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.

The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.

Sensors can be built into the part: NTC thermistor, PT100 or PT1000 RTD, or a K-type thermocouple, fitted under the same insulation and tested with the heater as one assembly. A sensor laminated into the heater reads the heater; a sensor on the load reads the load. Both are legitimate, and the drawing has to say which is wanted.

Attachment and Thermal Contact

Attachment options are a factory-applied pressure-sensitive adhesive, vulcanising or bonding to the customer's part, or mechanical clamping with a plate or a strap.

A PSA bond wants a clean, dry, degreased surface, continuous pressure while it wets out, and no trapped air: a bubble under the element is a spot with no thermal path, and it will be the first place the heater fails. Acrylic adhesives reach full strength over 24 to 72 hours, so the assembly is not at its rated watt density the moment it is pressed down.

From the capability table: Free, 3M 468MP or 9077 PSA backing, vulcanised to the part, or mechanically clamped.

The bond line is part of the thermal circuit and should be specified like one. A 0.05 mm acrylic PSA layer conducts roughly 0.2 W/m·K; a filled silicone adhesive is two to five times better, and a bolted joint with an interface pad better again. Whatever is chosen, it has to be continuous — the heater cannot spread heat sideways to cover a gap, and the temperature under a void rises until something in the stack gives way.

Leads and Terminations

Lead wire as supplied: Silicone-insulated stranded copper, 22 AWG to 16 AWG, PTFE where the exit is hot. Length, gauge, exit position and termination are drawing items — the exit position in particular, because it decides where the heater can be routed and it cannot be changed after the tool is cut.

The lead exit is a thermal discontinuity as well as an electrical one. The joint between a fine element and a stranded lead is the hottest point of many heaters, so it is kept out of the highest watt density zone, strain relieved, and — where the exit sits in a hot area — insulated in PTFE rather than in silicone.

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • An outline drawing, or a sketch with dimensions: overall size, holes, cut-outs, radii and the lead exit position.
  • The supply voltage, and whether it is AC or DC. The element is wound for one voltage; it is not a switchable range.
  • The power required, or — better — the temperature to be reached and the mass or flow it has to be reached in. Given the second, the wattage can be calculated instead of guessed.
  • What the heater is attached to, and how. This is what decides which watt density figure applies, and it is the question a quotation cannot proceed without.
  • The ambient, and the lowest temperature the assembly must start from. A heater sized for a 20 °C start is undersized for a -30 °C one.
  • Duty cycle: continuous, intermittent, or a warm-up to a deadline. Time to temperature is a specification, not a by-product.
  • Sensor and protection: which sensor, where it goes, and which limit device is fitted in series with the element.
  • The certification the end product is built to, named on the enquiry rather than after approval.
  • Quantity and target price, because the construction that is right for fifty pieces is often not the one that is right for fifty thousand.
  • Whether adhesive backing is wanted, and what surface it goes onto — a low-energy plastic needs a different adhesive from bare aluminium.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

Battery Formation Silicone Heaters — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
ConstructionNichrome resistance wire wound on a fibreglass carrier, or etched Inconel foil, vulcanised between two sheets of fibreglass-reinforced silicone rubberDecided at quotation from the outline and the wattage
Insulation systemFibreglass-reinforced silicone rubber, both facesThis is what sets the temperature limit, not the element
Total thickness2.0 mmNominal, before adhesive; add 0.2 mm for PSA backing
Minimum size25 x 25 mmBelow this the element cannot be routed with a safe edge margin
Maximum size, one piece600 x 1200 mmLarger areas are supplied as tiled zones with separate circuits
Dimensional toleranceu00b11.5 mm on dimensions up to 300 mm, u00b10.5%% aboveOn the die-cut outline; hole positions are held tighter
Supply voltage5 V DC to 240 V AC, wound to orderWound to the ordered voltage u2014 it is not a switchable range
Resistance toleranceu00b110% standard, u00b15% on requestMeasured at 20 u00b0C; hot resistance differs with the element alloy
Watt density, free air0.6 W/cmu00b2 typical, 0.9 W/cmu00b2 maximumNothing conducting heat away u2014 the honest figure for an unbonded heater
Watt density, bonded to heat sink4.0 W/cmu00b2 maximumOnly valid with full-area contact to metal; specifying at this figure and running in free air destroys the heater
Continuous working temperature-50 u00b0C to +200 u00b0C continuous (+240 u00b0C intermittent)Of the heater itself, measured at the element, not the ambient
Dielectric strength2500 V AC, 1 minuteOne minute, element to any exposed surface, no breakdown
Insulation resistancegreater than 100 Mu03a9At 500 V DC, measured after the dielectric test
Lead wireSilicone-insulated stranded copper, 22 AWG to 16 AWG, PTFE where the exit is hotLength, gauge and termination to your drawing
AttachmentFree, 3M 468MP or 9077 PSA backing, vulcanised to the part, or mechanically clampedAdhesive-backed heaters need continuous contact pressure while curing
Sensor and control optionsNTC 10K B3950, PT100/PT1000, K-type thermocouple, KSD9700 bimetal thermostat, thermal cutoffFitted under the same insulation and tested as one assembly
Certifications availableUL 499 construction, IEC/EN 60335, UL 94 V-0 materials, RoHS, REACH, CEConstructions are built to these; the certificate covers the construction, not every outline
Uniformityu00b12 u00b0C across the platen at 45 u00b0C set pointFormation yield depends on it u2014 a 5 u00b0C spread across a rack shows up as capacity spread
ColourBlue silicone standard; red, black or grey on requestColour is pigment only and changes nothing thermal

Capability figures are this factory's process limits for the construction described. Watt density limits follow the published maxima for fibreglass-reinforced silicone rubber heaters (to about 12 W/cm² bonded to a heat sink, far less in free air); continuous temperature limits are those of the silicone insulation system, not of the element alloy.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.

Build the Drawing

The panel above checks whether a size and a wattage can be built. This is the drawing itself: set the outline, route the heating track, place the lead wires, terminals, connector and temperature sensor, working in silicone rubber, and turn the model to look at it. When it is right, export the 2D drawing as a PDF or a DXF and send it with your enquiry — a drawing is what a quotation for battery formation silicone heaters is actually written from.

HEATING FILM DRAWING
Silicone Rubber Heater

Draw the outline, route the heating track, place the lead exits, terminals and sensor, dimension it, then export a PDF or a DXF and send it with your enquiry. Nothing here is a stock part and nothing you draw commits you to anything.

CMD

Want to compare constructions before you draw? Open the full builder, where every film family is selectable in one place.

Our facility

The numbers come off our own machines

Every unit is measured for resistance, held at its dielectric test voltage for a minute, and measured again for insulation resistance. Sample units from each lot are run under power and imaged. That is why the values on this page are quotable rather than indicative.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (UL 499 / IEC 60335 / RoHS)

ParameterSpecificationLimit / note
ConstructionNichrome resistance wire wound on a fibreglass carrier, or etched Inconel foil, vulcanised between two sheets of fibreglass-reinforced silicone rubberDecided at quotation from the outline and the wattage
Insulation systemFibreglass-reinforced silicone rubber, both facesThis is what sets the temperature limit, not the element
Total thickness2.0 mmNominal, before adhesive; add 0.2 mm for PSA backing
Minimum size25 x 25 mmBelow this the element cannot be routed with a safe edge margin
Maximum size, one piece600 x 1200 mmLarger areas are supplied as tiled zones with separate circuits
Dimensional toleranceu00b11.5 mm on dimensions up to 300 mm, u00b10.5%% aboveOn the die-cut outline; hole positions are held tighter
Supply voltage5 V DC to 240 V AC, wound to orderWound to the ordered voltage u2014 it is not a switchable range
Resistance toleranceu00b110% standard, u00b15% on requestMeasured at 20 u00b0C; hot resistance differs with the element alloy
Watt density, free air0.6 W/cmu00b2 typical, 0.9 W/cmu00b2 maximumNothing conducting heat away u2014 the honest figure for an unbonded heater
Watt density, bonded to heat sink4.0 W/cmu00b2 maximumOnly valid with full-area contact to metal; specifying at this figure and running in free air destroys the heater
Continuous working temperature-50 u00b0C to +200 u00b0C continuous (+240 u00b0C intermittent)Of the heater itself, measured at the element, not the ambient
Dielectric strength2500 V AC, 1 minuteOne minute, element to any exposed surface, no breakdown
Insulation resistancegreater than 100 Mu03a9At 500 V DC, measured after the dielectric test
Lead wireSilicone-insulated stranded copper, 22 AWG to 16 AWG, PTFE where the exit is hotLength, gauge and termination to your drawing
AttachmentFree, 3M 468MP or 9077 PSA backing, vulcanised to the part, or mechanically clampedAdhesive-backed heaters need continuous contact pressure while curing
Sensor and control optionsNTC 10K B3950, PT100/PT1000, K-type thermocouple, KSD9700 bimetal thermostat, thermal cutoffFitted under the same insulation and tested as one assembly
Certifications availableUL 499 construction, IEC/EN 60335, UL 94 V-0 materials, RoHS, REACH, CEConstructions are built to these; the certificate covers the construction, not every outline
Uniformityu00b12 u00b0C across the platen at 45 u00b0C set pointFormation yield depends on it u2014 a 5 u00b0C spread across a rack shows up as capacity spread
ColourBlue silicone standard; red, black or grey on requestColour is pigment only and changes nothing thermal

Video: IEC/EN 60335 Battery Formation Silicone Heaters

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

Does this heater need a thermostat?

Yes. It has no mechanism for limiting its own temperature — with the load removed or the control loop failed it keeps producing the same power — so the design needs a controller with a sensor to hold the set point and, separately, a bimetal thermostat or a one-shot thermal cutoff in series with the element as protection.

Is there a part number I can order?

No — these are made to your drawing, so a part number would describe something that was never built. A quotation needs the outline, the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. The table on this page is what the factory can hold, not a stock list.

How large can one piece be?

600 x 1200 mm in a single piece. Larger areas are supplied as tiled zones with separate circuits, which is usually better engineering anyway: separate zones can be controlled separately, and a large single circuit has to carry the whole current at one lead exit.

Is this heater IEC/EN 60335 approved?

The construction is built and tested to IEC/EN 60335; the outline is yours, and a made-to-drawing outline does not carry a certificate of its own. What is available is the construction file — the standard the build is tested to, the material ratings and the test reports — which is what your own product approval is built on.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.