Skip to content
Epoxy Heating Plates · UL 499 / IEC 60335 / RoHS

Aluminium Plate / Extrusion Epoxy Encapsulated Plate Heaters

How the plate turns a line element into a uniform surface, what that costs in thermal mass and response, and how the assembly is mounted.

Aluminium Plate / Extrusion — To +200 °C with epoxy encapsulation; higher with silicone or ceramic bonding. Spreads the heat before it reaches the load, which is what turns a line element into a uniform surface. The standard carrier for PTC assemblies and epoxy plates. In this construction it carries 0.5 W/cm² in free air and 3 W/cm² bonded over its whole area to metal.

Insulation system
Aluminium Plate / Extrusion
Temperature range
To +200 °C with epoxy encapsulation; higher with silicone or ceramic bonding
Where it stops
Adds thermal mass and therefore lag; not the choice where response time matters.
Continuous temperature limit
150 °C continuous
Watt density
0.5 W/cm² free air, 3 W/cm² bonded
Total thickness
6 mm to 15 mm

The temperature ceiling belongs to the insulation, not to the element: the resistance alloy would run far hotter, and it is the insulation around it that fails first. Figures are for the insulation system as built here; a part is quoted against the drawing, not against this table.

Epoxy Encapsulated Plate Heaters — the construction this guide is about

In epoxy encapsulated plate heaters, Aluminium Plate / Extrusion is the insulation system — and on a heater the insulation system is what sets the temperature limit, the flexibility and the dielectric strength. Its range is To +200 °C with epoxy encapsulation; higher with silicone or ceramic bonding. What that means in service, what attacks it, and what to use instead above its ceiling are below.

Aluminium Plate / Extrusion as an Insulation System

Spreads the heat before it reaches the load, which is what turns a line element into a uniform surface. The standard carrier for PTC assemblies and epoxy plates.

Working rangeTo +200 °C with epoxy encapsulation; higher with silicone or ceramic bonding
Total thickness in this construction6 mm to 15 mm
Dielectric withstand2500 V AC, 1 minute
Insulation resistancegreater than 100 Mu03a9 at 500 V DC
Maximum size, one piece400 x 600 mm

The metal is not the insulation — it is the spreader. It turns a line element into a uniform surface, and it is why the assembly is uniform and slow rather than fast and patchy. The insulation limit belongs to whatever bonds the element to it.

The Temperature Ceiling, and What Sets It

Working range: To +200 °C with epoxy encapsulation; higher with silicone or ceramic bonding. The ceiling belongs to the insulation. Nichrome will run red; aluminium plate / extrusion will not, and it is the material around the element that decides what the part is rated at.

This construction is rated 150 °C continuous. That is a continuous figure at the element, not an ambient and not a surface temperature measured somewhere convenient — and it is not a figure that derating extends downwards from something higher. Past the ceiling the insulation degrades, the dielectric strength falls with it, and the failure is electrical rather than thermal.

The boundaries across this catalogue are all material boundaries: PET stops at 120 °C, filled epoxy at 150 °C, silicone rubber and polyimide at 200 °C, and above that only fired and inorganic systems — thick film on stainless or alumina, and mica — are candidates at all.

What Attacks Aluminium Plate / Extrusion

Adds thermal mass and therefore lag; not the choice where response time matters.

What an Epoxy Encapsulated Plate Heaters Is

A flat, rigid, sealed heating plate: element potted in filled epoxy on aluminium, for conduction heating where a flexible heater will not stay flat.

A resistance wire or foil element vacuum potted in thermally conductive filled epoxy against an aluminium or steel plate. Rigid, flat, sealed, and thermally bonded to its own plate so the heat leaves the element through metal rather than through air.

The plate is the thermal path: the element is potted against it, so the metal spreads the heat before the load ever sees it. That is what buys uniformity, and it is also what makes the assembly slow — a bolted plate takes minutes to reach steady state where a film takes seconds.

Elementresistance wire or foil, vacuum potted
Insulation systemthermally conductive filled epoxy
Total thickness6 mm to 15 mm
Maximum size, one piece400 x 600 mm
Continuous working temperature150 °C

The continuous limit of 150 °C is set by thermally conductive filled epoxy. The element alloy would run far hotter; it is never the element that decides.

What the Insulation Changes About the Heater

The plate turns a line element into a surface. Uniformity across the heated face improves, hot spots over the element disappear, and the price is thermal mass: the same watts now have to heat the plate before they reach the load.

Attachment and Thermal Contact

The plate is drilled or tapped to your drawing and bolts to the machine. The heated face has to sit flat against the load; where it cannot, a thermal interface pad is worth more than extra wattage.

Allow for expansion. An aluminium plate 400 mm long grows about 1 mm between 20 °C and 130 °C, so a plate bolted rigidly at both ends will bow, and the bow lifts the middle of the heated face away from the load.

From the capability table: Tapped holes, clearance holes, studs or bonded.

The joint between the heated surface and the load carries every watt the element makes. Fill it: an interface pad, a thin film of thermal grease or a bonded assembly. Two dry surfaces bolted together are a thermal resistance, and that resistance appears as element temperature.

Watt Density: the Two Figures

This construction is rated at 0.5 W/cm² in free air and 3 W/cm² bonded over its whole area to metal. The second figure is 6 times the first, and the difference is not a safety margin — it is the heat sink. On a 100 x 150 mm outline, which is 150 cm², that is about 75 W hanging in air against about 45 W bonded down.

Specify at the figure that matches how the heater will actually run. A heater ordered at the bonded density and then switched on before it is attached — on the bench, during a test, after it has lifted off in service — reaches its insulation limit in minutes, because there is nowhere for the heat to go but through the insulation.

Control and Protection

This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.

The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.

The limit that matters is the epoxy's, at 150 °C, and it is reached at the element long before the plate face reads anything alarming. Put the limit device in the potting against the element, not on the outside of the plate.

Sensors can be built into the part: NTC thermistor, PT100 or PT1000 RTD, or a K-type thermocouple, fitted under the same insulation and tested with the heater as one assembly. A sensor laminated into the heater reads the heater; a sensor on the load reads the load. Both are legitimate, and the drawing has to say which is wanted.

T

h

Where This Construction Is the Wrong Answer

  • Do not plan on running above 150 °C. That ceiling belongs to the insulation system, not to the element alloy, and it is not a figure that derating extends — past it the insulation degrades and the dielectric strength goes with it.
  • Do not put an epoxy plate where a flexible heater is really wanted. It will not conform, and clamping it against a surface that is not flat loads the potting rather than the joint.

Leads and Terminations

Termination is specified on the drawing: lead length, gauge, insulation and the connector or tag at the end of it.

The lead exit is a thermal discontinuity as well as an electrical one. The joint between a fine element and a stranded lead is the hottest point of many heaters, so it is kept out of the highest watt density zone, strain relieved, and — where the exit sits in a hot area — insulated in PTFE rather than in silicone.

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • An outline drawing, or a sketch with dimensions: overall size, holes, cut-outs, radii and the lead exit position.
  • The supply voltage, and whether it is AC or DC. The element is wound for one voltage; it is not a switchable range.
  • The power required, or — better — the temperature to be reached and the mass or flow it has to be reached in. Given the second, the wattage can be calculated instead of guessed.
  • What the heater is attached to, and how. This is what decides which watt density figure applies, and it is the question a quotation cannot proceed without.
  • The ambient, and the lowest temperature the assembly must start from. A heater sized for a 20 °C start is undersized for a -30 °C one.
  • Duty cycle: continuous, intermittent, or a warm-up to a deadline. Time to temperature is a specification, not a by-product.
  • Sensor and protection: which sensor, where it goes, and which limit device is fitted in series with the element.
  • The certification the end product is built to, named on the enquiry rather than after approval.
  • Quantity and target price, because the construction that is right for fifty pieces is often not the one that is right for fifty thousand.
  • The plate material, thickness and mounting hole pattern, and what the plate is bolted to.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

Epoxy Encapsulated Plate Heaters — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
ConstructionResistance wire or foil element potted in thermally conductive filled epoxy on a metal plateCured under vacuum so there are no voids in the heat path
Plate materialAluminium 6061, 3 mm to 10 mmAluminium for spreading, stainless where the chemistry demands it
Total thickness6 mm to 15 mmPlate plus encapsulation
Maximum size, one piece400 x 600 mmLarger plates are built as multiple circuits on one plate
Dimensional toleranceu00b10.5 mm on the plate, u00b11 mm on the encapsulation
Supply voltage24 V, 48 V, 110 V, 220 VWound to order
Resistance toleranceu00b110%At 20 u00b0C
Watt density0.5 W/cmu00b2 typical, 3.0 W/cmu00b2 maximumAgainst a load in contact; free-standing operation runs far lower
Continuous working temperature-40 u00b0C to +150 u00b0CSet by the epoxy, not by the element
Dielectric strength2500 V AC, 1 minuteElement to plate
Insulation resistancegreater than 100 Mu03a9 at 500 V DCAlso after 48 hours humidity conditioning
Ingress protectionIP65 as standard, IP67 with a moulded lead entryThe encapsulation is the seal
MountingTapped holes, clearance holes, studs or bondedMachined into the plate before potting
Sensor optionsNTC, PT100 or thermostat potted into the same plateReads the plate, which is what the load actually sees
Certifications availableUL 499, IEC/EN 60335, RoHS, REACH, CE, IATF 16949Construction level

Capability figures are for resistance elements encapsulated in thermally conductive filled epoxy on a metal plate. The +150 °C continuous limit is a property of the encapsulant, and it is the lowest limit of any construction in this catalog — the element and the plate would both tolerate far more.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.

Build the Drawing

The panel above checks whether a size and a wattage can be built. This is the drawing itself: set the outline, route the heating track, place the lead wires, terminals, connector and temperature sensor, working in custom outline, and turn the model to look at it. When it is right, export the 2D drawing as a PDF or a DXF and send it with your enquiry — a drawing is what a quotation for epoxy encapsulated plate heaters is actually written from.

HEATING FILM DRAWING
Custom / Special-Shaped Heating Film

Draw the outline, route the heating track, place the lead exits, terminals and sensor, dimension it, then export a PDF or a DXF and send it with your enquiry. Nothing here is a stock part and nothing you draw commits you to anything.

CMD

Want to compare constructions before you draw? Open the full builder, where every film family is selectable in one place.

Our facility

Held in production, not just on paper

The limits above are the ones our own lamination press, die and test lines actually hold, and every unit is tested rather than a sample. A figure is only worth quoting if it survives the process that produces it.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (UL 499 / IEC 60335 / RoHS)

ParameterSpecificationLimit / note
ConstructionResistance wire or foil element potted in thermally conductive filled epoxy on a metal plateCured under vacuum so there are no voids in the heat path
Plate materialAluminium 6061, 3 mm to 10 mmAluminium for spreading, stainless where the chemistry demands it
Total thickness6 mm to 15 mmPlate plus encapsulation
Maximum size, one piece400 x 600 mmLarger plates are built as multiple circuits on one plate
Dimensional toleranceu00b10.5 mm on the plate, u00b11 mm on the encapsulation
Supply voltage24 V, 48 V, 110 V, 220 VWound to order
Resistance toleranceu00b110%At 20 u00b0C
Watt density0.5 W/cmu00b2 typical, 3.0 W/cmu00b2 maximumAgainst a load in contact; free-standing operation runs far lower
Continuous working temperature-40 u00b0C to +150 u00b0CSet by the epoxy, not by the element
Dielectric strength2500 V AC, 1 minuteElement to plate
Insulation resistancegreater than 100 Mu03a9 at 500 V DCAlso after 48 hours humidity conditioning
Ingress protectionIP65 as standard, IP67 with a moulded lead entryThe encapsulation is the seal
MountingTapped holes, clearance holes, studs or bondedMachined into the plate before potting
Sensor optionsNTC, PT100 or thermostat potted into the same plateReads the plate, which is what the load actually sees
Certifications availableUL 499, IEC/EN 60335, RoHS, REACH, CE, IATF 16949Construction level

Video: Aluminium Plate / Extrusion Epoxy Encapsulated Plate Heaters

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

What watt density can epoxy encapsulated plate heaters run at?

0.5 W/cm² with nothing conducting the heat away, and 3 W/cm² bonded over its whole area to metal. The two figures describe two different installations, not a range to choose from: a heater specified at 3 W/cm² and then run in free air reaches its insulation limit within minutes.

What is the maximum temperature of epoxy encapsulated plate heaters?

150 °C continuous, measured at the element. The limit belongs to thermally conductive filled epoxy and not to the element alloy, so it is not a figure that can be extended by derating the power.

Does this heater need a thermostat?

Yes. It has no mechanism for limiting its own temperature — with the load removed or the control loop failed it keeps producing the same power — so the design needs a controller with a sensor to hold the set point and, separately, a bimetal thermostat or a one-shot thermal cutoff in series with the element as protection.

Is there a part number I can order?

No — these are made to your drawing, so a part number would describe something that was never built. A quotation needs the outline, the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. The table on this page is what the factory can hold, not a stock list.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.