Working temperature page for printed carbon film heaters at 80 °c to 120 °c. What survives this band, what stops just below it, why the boundary is where it is, and how the temperature is actually measured and held.
What the 80 °C to 120 °C Band Requires
Battery operating windows, incubators, fluid warming and display heating. The upper limit of PET film, and the band where a low-cost printed heater stops being a candidate.
| Band | 80 °C to 120 °C |
|---|---|
| This construction, continuous | 120 °C |
| Limited by | PET polyester film |
This band reaches the ceiling of the construction. At 120 °C there is no headroom left, so the control has to hold the set point rather than approach it from above, and the limit device has to be set where it can act before the insulation does. A duty that spends its time at the top of the band is a duty that should be quoted against the next construction up.
Why the Boundary Is Where It Is
120 °C is where PET film stops. The polyester softens from about 130 °C and loses its dielectric strength as it softens, so the margin between working temperature and failure is thin — and a failure here is an electrical one, not a cosmetic one.
This is therefore the last band in which the cheapest thin heater is a candidate. Above it, the construction changes to silicone or polyimide, and the cost per square metre changes with it.
What a Printed Carbon Film Heaters Is
Carbon ink printed on PET: the lowest cost per square metre of any construction here, and the standard answer for large, low watt density heated areas.
Carbon or silver ink screen printed onto PET polyester film, laminated and die cut. It is made on a roll, which makes it the cheapest heater per square metre by a wide margin at volume, and it stops at 120 °C because the film does.
The heat leaves through the bonded face. Everything that is not in contact with the load radiates and convects from the back of the heater instead, which at these thicknesses is a poor path — so an air gap under part of the outline is not a small loss of efficiency, it is a hot spot at that spot.
| Element | screen-printed carbon or silver ink |
|---|---|
| Insulation system | PET polyester film |
| Total thickness | 0.2 mm |
| Maximum size, one piece | 500 x 1500 mm |
| Continuous working temperature | 120 °C |
The continuous limit of 120 °C is set by PET polyester film. The element alloy would run far hotter; it is never the element that decides.
Which Temperature Is Being Held
Three temperatures matter and they are not the same number: the element temperature, the temperature of the surface being heated, and the ambient. A heater rated for a continuous working temperature is rated at the element — the hottest point in the assembly, and the one nothing on the outside is measuring.
The gap between element and surface is the thermal path. Bonded to metal it may be a few degrees; across an air gap, a void in the adhesive or a dry clamped joint it can be tens of degrees, and every one of them appears at the element rather than at the load.
Which is why sensor position is a drawing item. A sensor laminated into the heater protects the heater; a sensor on the load controls the load. Assemblies that have to do both carry two: a control sensor where the process is, and a limit device against the element.
Watt Density: the Two Figures
Watt density, not wattage, is what the construction is limited by. 0.1 W/cm² unbonded and 0.5 W/cm² bonded to metal are the limits for this build — so if the wattage is fixed by the duty, the area is what has to move.
Where the required power will not fit into the available area at the free-air figure, the answer is a better thermal path rather than a thinner margin: bond the whole face down, or add a spreader plate. On 150 cm² the difference is roughly 15 W against 75 W, which is usually the whole argument.
Control and Protection
This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.
The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.
PET softens at about 130 °C and loses its dielectric strength as it does, so the cutoff temperature has to sit under that with margin. This is a construction that cannot be allowed to dry out and overshoot.
Sensors can be built into the part: NTC thermistor, PT100 or PT1000 RTD, or a K-type thermocouple, fitted under the same insulation and tested with the heater as one assembly. A sensor laminated into the heater reads the heater; a sensor on the load reads the load. Both are legitimate, and the drawing has to say which is wanted.
Where This Construction Is the Wrong Answer
- Do not plan on running above 120 °C. That ceiling belongs to the insulation system, not to the element alloy, and it is not a figure that derating extends — past it the insulation degrades and the dielectric strength goes with it.
- Do not use PET film for process heat. At 120 °C it is at its ceiling, and the constructions that go above it — silicone, polyimide, thick film — are different parts, not the same part with a different rating.
Other Constructions That Hold 80 °C to 120 °C
Constructions in this catalogue that will hold 80 °c to 120 °c continuously:
How to Specify One
This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:
- An outline drawing, or a sketch with dimensions: overall size, holes, cut-outs, radii and the lead exit position.
- The supply voltage, and whether it is AC or DC. The element is wound for one voltage; it is not a switchable range.
- The power required, or — better — the temperature to be reached and the mass or flow it has to be reached in. Given the second, the wattage can be calculated instead of guessed.
- What the heater is attached to, and how. This is what decides which watt density figure applies, and it is the question a quotation cannot proceed without.
- The ambient, and the lowest temperature the assembly must start from. A heater sized for a 20 °C start is undersized for a -30 °C one.
- Duty cycle: continuous, intermittent, or a warm-up to a deadline. Time to temperature is a specification, not a by-product.
- Sensor and protection: which sensor, where it goes, and which limit device is fitted in series with the element.
- The certification the end product is built to, named on the enquiry rather than after approval.
- Quantity and target price, because the construction that is right for fifty pieces is often not the one that is right for fifty thousand.
- Whether adhesive backing is wanted, and what surface it goes onto — a low-energy plastic needs a different adhesive from bare aluminium.
Lead time: Samples 7-10 days from approved drawing; production 15-20 days.
Printed Carbon Film Heaters — Capability Table
These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.
| Parameter | Specification | Limit / note |
|---|---|---|
| Construction | Carbon-loaded ink screen printed on PET film, silver bus bars, laminated | Decided at quotation from the outline and the wattage |
| Insulation system | PET polyester film, 0.05 mm to 0.125 mm per face | This is what sets the temperature limit, not the element |
| Total thickness | 0.2 mm | Nominal, before adhesive; add 0.2 mm for PSA backing |
| Minimum size | 20 x 20 mm | Below this the element cannot be routed with a safe edge margin |
| Maximum size, one piece | 500 x 1500 mm | Larger areas are supplied as tiled zones with separate circuits |
| Dimensional tolerance | u00b11 mm on the die-cut outline | On the die-cut outline; hole positions are held tighter |
| Supply voltage | 12 V, 24 V, 48 V, 110 V, 220 V | Wound to the ordered voltage u2014 it is not a switchable range |
| Resistance tolerance | u00b110% standard, u00b15% on request | Measured at 20 u00b0C; hot resistance differs with the element alloy |
| Watt density, free air | 0.1 W/cmu00b2 typical | Nothing conducting heat away u2014 the honest figure for an unbonded heater |
| Watt density, bonded to heat sink | 0.5 W/cmu00b2 maximum | Only valid with full-area contact to metal; specifying at this figure and running in free air destroys the heater |
| Continuous working temperature | -40 u00b0C to +120 u00b0C continuous | Of the heater itself, measured at the element, not the ambient |
| Dielectric strength | 1500 V AC, 1 minute | One minute, element to any exposed surface, no breakdown |
| Insulation resistance | greater than 100 Mu03a9 | At 500 V DC, measured after the dielectric test |
| Lead wire | Crimped or soldered leads, or a printed silver bus bar with a bonded tail | Length, gauge and termination to your drawing |
| Attachment | PSA backing standard; laminated into the end product at high volume | Adhesive-backed heaters need continuous contact pressure while curing |
| Sensor and control options | NTC 10K B3950 bonded to the film, or a printed PTC ink track | Fitted under the same insulation and tested as one assembly |
| Certifications available | IEC/EN 60335, UL 94 V-0, RoHS, REACH, CE, IATF 16949 | Constructions are built to these; the certificate covers the construction, not every outline |
| Cost | Roll-to-roll printing u2014 the cheapest heater per square metre at volume | The saving is real above a few thousand pieces and disappears below a few hundred |
| Positive temperature coefficient | Carbon ink resistance rises slightly with temperature | A mild self-limiting effect, not a substitute for a thermostat |
Capability figures are for screen-printed carbon or silver ink on PET polyester film. The +120 °C continuous limit is the film's, and it is a hard limit: PET softens and loses dielectric strength above roughly 130 °C, so this construction is only a candidate where the maximum credible temperature is bounded well below it.