Skip to content
PET Film Heaters · IEC 60335 / UL 94 V-0 / RoHS

Printed Carbon Film Heaters for Up to 80 °C

Which insulation systems hold Up to 80 °C continuously, what this construction is rated to, and the control and cut-out that hold the surface there.

Printed Carbon Film Heaters are rated 120 °C continuous, a limit set by the PET polyester film, which covers Up to 80 °C. Comfort and condensation control: seat heating, mirror demisting, enclosure anti-condensation, battery pre-conditioning. Almost any construction reaches it, so the choice is decided by cost and thickness rather than by the temperature.

Working band
Up to 80 °C
Continuous limit, this construction
120 °C
Set by
PET polyester film
Watt density
0.1 W/cm² free air, 0.5 W/cm² bonded
Total thickness
0.2 mm
Maximum outline, one piece
500 x 1500 mm

The band is the temperature the heated surface has to hold, not the temperature the element reaches. The element always runs hotter, by an amount the watt density and the thermal path decide, so the cut-out is set against the element and not against the load.

Printed Carbon Film Heaters — the construction this guide is about

Duty temperature decides the construction before anything else does. At up to 80 °c, printed carbon film heaters is a candidate; the sections below set out what it will hold, what has to be true for it to hold it, and what fails first when it does not.

What the Up to 80 °C Band Requires

Comfort and condensation control: seat heating, mirror demisting, enclosure anti-condensation, battery pre-conditioning. Almost any construction reaches it, so the choice is decided by cost and thickness rather than by the temperature.

BandUp to 80 °C
This construction, continuous120 °C
Limited byPET polyester film

The band sits comfortably inside the 120 °C ceiling, which is where a heater should be specified: the margin between the working temperature and the insulation limit is what absorbs a poor thermal path, a warm ambient and a control overshoot without shortening the life of the part.

Why the Boundary Is Where It Is

80 °C is not a material boundary at all — every construction here passes through it — so the choice inside this band is decided by cost, thickness and area rather than by temperature. That is why printed film competes here and nowhere above it.

The engineering in this band is uniformity and control, not survival: comfort heating, condensation control and battery pre-conditioning all care about holding a few degrees evenly over a large area, which is a watt density and layout problem.

What a Printed Carbon Film Heaters Is

Carbon ink printed on PET: the lowest cost per square metre of any construction here, and the standard answer for large, low watt density heated areas.

Carbon or silver ink screen printed onto PET polyester film, laminated and die cut. It is made on a roll, which makes it the cheapest heater per square metre by a wide margin at volume, and it stops at 120 °C because the film does.

The heat leaves through the bonded face. Everything that is not in contact with the load radiates and convects from the back of the heater instead, which at these thicknesses is a poor path — so an air gap under part of the outline is not a small loss of efficiency, it is a hot spot at that spot.

Elementscreen-printed carbon or silver ink
Insulation systemPET polyester film
Total thickness0.2 mm
Maximum size, one piece500 x 1500 mm
Continuous working temperature120 °C

The continuous limit of 120 °C is set by PET polyester film. The element alloy would run far hotter; it is never the element that decides.

Which Temperature Is Being Held

Three temperatures matter and they are not the same number: the element temperature, the temperature of the surface being heated, and the ambient. A heater rated for a continuous working temperature is rated at the element — the hottest point in the assembly, and the one nothing on the outside is measuring.

The gap between element and surface is the thermal path. Bonded to metal it may be a few degrees; across an air gap, a void in the adhesive or a dry clamped joint it can be tens of degrees, and every one of them appears at the element rather than at the load.

Which is why sensor position is a drawing item. A sensor laminated into the heater protects the heater; a sensor on the load controls the load. Assemblies that have to do both carry two: a control sensor where the process is, and a limit device against the element.

Watt Density: the Two Figures

Two watt densities are quoted because there are two thermal situations. With nothing conducting heat away, 0.1 W/cm² is what the insulation survives. Bonded to a heat sink over the full outline, 0.5 W/cm² is. Anything in between depends on the quality of the joint, and the joint is the customer's to make.

The failure is silent and quick: the element does not know how it is mounted, so at 0.5 W/cm² in free air the heat simply accumulates in the insulation until it degrades. This is the single most common way these heaters are destroyed, and it happens on the first run rather than after a year.

Control and Protection

This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.

The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.

PET softens at about 130 °C and loses its dielectric strength as it does, so the cutoff temperature has to sit under that with margin. This is a construction that cannot be allowed to dry out and overshoot.

Sensors can be built into the part: NTC thermistor, PT100 or PT1000 RTD, or a K-type thermocouple, fitted under the same insulation and tested with the heater as one assembly. A sensor laminated into the heater reads the heater; a sensor on the load reads the load. Both are legitimate, and the drawing has to say which is wanted.

Where This Construction Is the Wrong Answer

  • Do not plan on running above 120 °C. That ceiling belongs to the insulation system, not to the element alloy, and it is not a figure that derating extends — past it the insulation degrades and the dielectric strength goes with it.
  • Do not use PET film for process heat. At 120 °C it is at its ceiling, and the constructions that go above it — silicone, polyimide, thick film — are different parts, not the same part with a different rating.

Other Constructions That Hold Up to 80 °C

Constructions in this catalogue that will hold up to 80 °c continuously:

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • An outline drawing, or a sketch with dimensions: overall size, holes, cut-outs, radii and the lead exit position.
  • The supply voltage, and whether it is AC or DC. The element is wound for one voltage; it is not a switchable range.
  • The power required, or — better — the temperature to be reached and the mass or flow it has to be reached in. Given the second, the wattage can be calculated instead of guessed.
  • What the heater is attached to, and how. This is what decides which watt density figure applies, and it is the question a quotation cannot proceed without.
  • The ambient, and the lowest temperature the assembly must start from. A heater sized for a 20 °C start is undersized for a -30 °C one.
  • Duty cycle: continuous, intermittent, or a warm-up to a deadline. Time to temperature is a specification, not a by-product.
  • Sensor and protection: which sensor, where it goes, and which limit device is fitted in series with the element.
  • The certification the end product is built to, named on the enquiry rather than after approval.
  • Quantity and target price, because the construction that is right for fifty pieces is often not the one that is right for fifty thousand.
  • Whether adhesive backing is wanted, and what surface it goes onto — a low-energy plastic needs a different adhesive from bare aluminium.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

Printed Carbon Film Heaters — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
ConstructionCarbon-loaded ink screen printed on PET film, silver bus bars, laminatedDecided at quotation from the outline and the wattage
Insulation systemPET polyester film, 0.05 mm to 0.125 mm per faceThis is what sets the temperature limit, not the element
Total thickness0.2 mmNominal, before adhesive; add 0.2 mm for PSA backing
Minimum size20 x 20 mmBelow this the element cannot be routed with a safe edge margin
Maximum size, one piece500 x 1500 mmLarger areas are supplied as tiled zones with separate circuits
Dimensional toleranceu00b11 mm on the die-cut outlineOn the die-cut outline; hole positions are held tighter
Supply voltage12 V, 24 V, 48 V, 110 V, 220 VWound to the ordered voltage u2014 it is not a switchable range
Resistance toleranceu00b110% standard, u00b15% on requestMeasured at 20 u00b0C; hot resistance differs with the element alloy
Watt density, free air0.1 W/cmu00b2 typicalNothing conducting heat away u2014 the honest figure for an unbonded heater
Watt density, bonded to heat sink0.5 W/cmu00b2 maximumOnly valid with full-area contact to metal; specifying at this figure and running in free air destroys the heater
Continuous working temperature-40 u00b0C to +120 u00b0C continuousOf the heater itself, measured at the element, not the ambient
Dielectric strength1500 V AC, 1 minuteOne minute, element to any exposed surface, no breakdown
Insulation resistancegreater than 100 Mu03a9At 500 V DC, measured after the dielectric test
Lead wireCrimped or soldered leads, or a printed silver bus bar with a bonded tailLength, gauge and termination to your drawing
AttachmentPSA backing standard; laminated into the end product at high volumeAdhesive-backed heaters need continuous contact pressure while curing
Sensor and control optionsNTC 10K B3950 bonded to the film, or a printed PTC ink trackFitted under the same insulation and tested as one assembly
Certifications availableIEC/EN 60335, UL 94 V-0, RoHS, REACH, CE, IATF 16949Constructions are built to these; the certificate covers the construction, not every outline
CostRoll-to-roll printing u2014 the cheapest heater per square metre at volumeThe saving is real above a few thousand pieces and disappears below a few hundred
Positive temperature coefficientCarbon ink resistance rises slightly with temperatureA mild self-limiting effect, not a substitute for a thermostat

Capability figures are for screen-printed carbon or silver ink on PET polyester film. The +120 °C continuous limit is the film's, and it is a hard limit: PET softens and loses dielectric strength above roughly 130 °C, so this construction is only a candidate where the maximum credible temperature is bounded well below it.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.

Build the Drawing

The panel above checks whether a size and a wattage can be built. This is the drawing itself: set the outline, route the heating track, place the lead wires, terminals, connector and temperature sensor, working in PET / PTC film, and turn the model to look at it. When it is right, export the 2D drawing as a PDF or a DXF and send it with your enquiry — a drawing is what a quotation for printed carbon film heaters is actually written from.

HEATING FILM DRAWING
PET / PTC Film Heater

Draw the outline, route the heating track, place the lead exits, terminals and sensor, dimension it, then export a PDF or a DXF and send it with your enquiry. Nothing here is a stock part and nothing you draw commits you to anything.

CMD

Want to compare constructions before you draw? Open the full builder, where every film family is selectable in one place.

Our facility

Held in production, not just on paper

The limits above are the ones our own lamination press, die and test lines actually hold, and every unit is tested rather than a sample. A figure is only worth quoting if it survives the process that produces it.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (IEC 60335 / UL 94 V-0 / RoHS)

ParameterSpecificationLimit / note
ConstructionCarbon-loaded ink screen printed on PET film, silver bus bars, laminatedDecided at quotation from the outline and the wattage
Insulation systemPET polyester film, 0.05 mm to 0.125 mm per faceThis is what sets the temperature limit, not the element
Total thickness0.2 mmNominal, before adhesive; add 0.2 mm for PSA backing
Minimum size20 x 20 mmBelow this the element cannot be routed with a safe edge margin
Maximum size, one piece500 x 1500 mmLarger areas are supplied as tiled zones with separate circuits
Dimensional toleranceu00b11 mm on the die-cut outlineOn the die-cut outline; hole positions are held tighter
Supply voltage12 V, 24 V, 48 V, 110 V, 220 VWound to the ordered voltage u2014 it is not a switchable range
Resistance toleranceu00b110% standard, u00b15% on requestMeasured at 20 u00b0C; hot resistance differs with the element alloy
Watt density, free air0.1 W/cmu00b2 typicalNothing conducting heat away u2014 the honest figure for an unbonded heater
Watt density, bonded to heat sink0.5 W/cmu00b2 maximumOnly valid with full-area contact to metal; specifying at this figure and running in free air destroys the heater
Continuous working temperature-40 u00b0C to +120 u00b0C continuousOf the heater itself, measured at the element, not the ambient
Dielectric strength1500 V AC, 1 minuteOne minute, element to any exposed surface, no breakdown
Insulation resistancegreater than 100 Mu03a9At 500 V DC, measured after the dielectric test
Lead wireCrimped or soldered leads, or a printed silver bus bar with a bonded tailLength, gauge and termination to your drawing
AttachmentPSA backing standard; laminated into the end product at high volumeAdhesive-backed heaters need continuous contact pressure while curing
Sensor and control optionsNTC 10K B3950 bonded to the film, or a printed PTC ink trackFitted under the same insulation and tested as one assembly
Certifications availableIEC/EN 60335, UL 94 V-0, RoHS, REACH, CE, IATF 16949Constructions are built to these; the certificate covers the construction, not every outline
CostRoll-to-roll printing u2014 the cheapest heater per square metre at volumeThe saving is real above a few thousand pieces and disappears below a few hundred
Positive temperature coefficientCarbon ink resistance rises slightly with temperatureA mild self-limiting effect, not a substitute for a thermostat

Video: Printed Carbon Film Heaters for Up to 80 °C

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

How large can one piece be?

500 x 1500 mm in a single piece. Larger areas are supplied as tiled zones with separate circuits, which is usually better engineering anyway: separate zones can be controlled separately, and a large single circuit has to carry the whole current at one lead exit.

Which heaters work at up to 80 °c?

Comfort and condensation control: seat heating, mirror demisting, enclosure anti-condensation, battery pre-conditioning. Almost any construction reaches it, so the choice is decided by cost and thickness rather than by the temperature.

Is the temperature rating the surface temperature or the element temperature?

The element temperature, which is the hottest point in the assembly and the one nothing on the outside is measuring. The surface being heated sits below it by whatever the thermal path costs — a few degrees through a good bond, tens of degrees across a void or a dry clamped joint.

What watt density can printed carbon film heaters run at?

0.1 W/cm² with nothing conducting the heat away, and 0.5 W/cm² bonded over its whole area to metal. The two figures describe two different installations, not a range to choose from: a heater specified at 0.5 W/cm² and then run in free air reaches its insulation limit within minutes.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.