5 V DC PT100 and PT1000 RTD Sensors

How this construction is wound for 5 V DC, with the temperature the insulation holds continuously and the control and cut-out the design has to carry.

5 V DC PT100 and PT1000 RTD Sensors: continuous limit 400 °C continuous, total thickness Component, maximum single-piece outline Component. At 5 V every 100 W of element power draws about 20 A, so the lead gauge, the connector and the switching device are sized from the wattage before anything else is decided.

Supply
5 V DC
Continuous temperature limit
400 °C continuous
Total thickness
Component
Maximum outline, one piece
Component

The element is wound to a resistance, so power follows the square of the supply: the same part on 240 V instead of 220 V makes about 19% more heat. The supply voltage is a drawing item, not a preference, and a heater wound for one voltage is not derated onto another.

PT100 and PT1000 RTD Sensors — the construction this guide is about

What 5 V DC means for pt100 and pt1000 rtd sensors: at 5 V DC, power follows P = V²/R, so a 10 W element is 2.5 Ω and draws 2 A. Everything downstream of that — conductor gauge, connector rating, the switching device and the isolation the assembly needs — follows from those two numbers.

The Element at 5 V DC

Two equations do all the work: P = V²/R and I = P/V. At 5 V DC, 10 W is 2.5 Ω and 2 A.

Worked example10 W at 5 V DC
Element resistance, R = V²/P2.5 Ω
Current, I = P/V2 A

The span matters more than the example. At 5 V DC a 20 W element is 1 Ω and a 500 W element is 0.1 Ω — a factor of twenty-five in resistance, met by changing the conductor cross-section and the length of the path, both of which are constrained by the outline.

At low voltage the difficulty is current, not insulation. 2 A wants 16 AWG rather than 22 AWG lead wire: 16 AWG is about 13 mΩ per metre, so a 2 m pair adds roughly 0.053 Ω to the circuit and dissipates 0.2 W in the leads instead of in the heater. Contact resistance at a crimp or a connector sits in series with the element in exactly the same way, and on a 1 Ω element a 20 mΩ joint is 2% of the power lost where nobody is looking for it.

The design consequence is that lead length and termination are part of the specification at low voltage. On a 5 V element the leads and the connector can account for a tenth of the total resistance, which shows up directly as a heater that never reaches temperature.

Isolation, Earthing and Safety Class

5 V DC is inside the safety extra-low voltage band, so the supply itself is not a shock hazard and the heater does not need a protective earth or double insulation on that account. The low voltage directive does not apply below 75 V DC.

What still applies is everything else: the element is at the far end of a circuit that can deliver a large current, so short-circuit protection, conductor sizing and the thermal cutoff are unchanged. Low voltage removes the shock risk, not the fire risk.

What a PT100 and PT1000 RTD Sensors Is

Platinum resistance sensors for anything that has to be accurate, repeatable and calibratable — process plates, medical warming, and any loop that gets validated.

A sensing component, specified by its tolerance class, its usable range and its response time. It has no watt density and no outline; it is fitted to a heater or to the surface the heater is warming, and where it is fitted decides what the control loop is actually controlling.

The heat leaves through whatever the component is clamped or bonded to; a sensing component adds no heat of its own and simply has to be in thermal contact with the thing it is reporting on.

Total thicknessComponent
Maximum size, one pieceComponent
Continuous working temperature400 °C

The continuous limit of 400 °C is set by the insulation system. The element alloy would run far hotter; it is never the element that decides.

Switching a DC Element

DC has no zero crossing, so a mechanical contact has to break the arc itself. A relay rated 10 A at 250 V AC may be rated 1 A or less at 30 V DC for exactly that reason, and using the AC number is how contacts weld closed — with a resistive heater on the other side, a welded contact is a heater that cannot be turned off. At 5 V DC and 2 A, use a MOSFET, a DC-rated solid state relay or a contactor with a DC rating.

PWM is the natural control method on DC, and a low frequency is right: a few hertz to a few hundred hertz is plenty for something with the thermal time constant of a heater, and it keeps the switching losses and the emissions down. There is nothing to gain from switching a thermal load at 20 kHz.

One DC-specific failure mode is worth naming: a continuous DC bias across a damp printed circuit drives electrochemical migration between adjacent tracks. It is why a silver-ink element in a humid installation is specified with a conformal barrier or reversed periodically, and why carbon ink is still used where the geometry allows it.

Leads and Terminations

Termination is specified on the drawing: lead length, gauge, insulation and the connector or tag at the end of it.

The lead exit is a thermal discontinuity as well as an electrical one. The joint between a fine element and a stranded lead is the hottest point of many heaters, so it is kept out of the highest watt density zone, strain relieved, and — where the exit sits in a hot area — insulated in PTFE rather than in silicone.

Control and Protection

This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.

The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.

Which Constructions Are Wound for 5 V DC

5 V DC is not unique to this construction. In this catalogue it is also wound into:

The supply voltage is wound in at manufacture. A heater built for one voltage cannot be run on another and rated down by arithmetic — at half the voltage it makes a quarter of the power, and at twice the voltage it makes four times the power and destroys itself.

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • The temperature to be sensed or switched, and the tolerance the application actually needs.
  • Where the component sits — against the element, in the potting, on the load, or in the airflow.
  • The electrical duty: for a switching device, the voltage, the current and whether the load is AC or DC.
  • Lead length, insulation and termination, and whether the component is fitted by us into a heater assembly or supplied loose.
  • The standard the end product is certified to, so the component chosen is one that fits inside that approval.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

PT100 and PT1000 RTD Sensors — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
TypeThin film platinum resistance temperature detectorNearly linear, and its characteristic is defined by standard
StandardIEC 60751, class AA / A / BClass A is u00b10.15 u00b0C at 0 u00b0C; class B is u00b10.3 u00b0C
Nominal resistance100 u03a9 (PT100) or 1000 u03a9 (PT1000) at 0 u00b0CPT1000 is preferred on long low-voltage runs: lead resistance matters ten times less
Temperature range-50 u00b0C to +400 u00b0CThe element itself; the leads and potting are usually the limit
Wiring2, 3 or 4 wire2-wire adds the lead resistance to the reading u2014 use 3-wire beyond a metre
Self heatingKeep the measuring current at or below 1 mAA sensor heated by its own excitation current reads high, consistently
EncapsulationLaminated into the heater, in a stainless probe, or surface bonded
CalibrationCertificate traceable to national standards on requestRequired for validated processes

Figures are the published tolerance and rating bands of the standard sensor and control components fitted to these heaters. Sensor tolerance classes follow IEC 60751 for RTDs and IEC 60584 for thermocouples; thermostat and thermal cutoff ratings are the component manufacturers' own.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.
Our facility

Held in production, not just on paper

The limits above are the ones our own lamination press, die and test lines actually hold, and every unit is tested rather than a sample. A figure is only worth quoting if it survives the process that produces it.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (IEC 60751 / IEC 60730 / RoHS)

ParameterSpecificationLimit / note
TypeThin film platinum resistance temperature detectorNearly linear, and its characteristic is defined by standard
StandardIEC 60751, class AA / A / BClass A is u00b10.15 u00b0C at 0 u00b0C; class B is u00b10.3 u00b0C
Nominal resistance100 u03a9 (PT100) or 1000 u03a9 (PT1000) at 0 u00b0CPT1000 is preferred on long low-voltage runs: lead resistance matters ten times less
Temperature range-50 u00b0C to +400 u00b0CThe element itself; the leads and potting are usually the limit
Wiring2, 3 or 4 wire2-wire adds the lead resistance to the reading u2014 use 3-wire beyond a metre
Self heatingKeep the measuring current at or below 1 mAA sensor heated by its own excitation current reads high, consistently
EncapsulationLaminated into the heater, in a stainless probe, or surface bonded
CalibrationCertificate traceable to national standards on requestRequired for validated processes

Video: 5 V DC PT100 and PT1000 RTD Sensors

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

Can a 5 V DC heater be run on another voltage?

No. The element is wound for one voltage at manufacture. Power goes with the square of the supply, so at half the voltage it makes a quarter of the power and at twice the voltage it makes four times the power — which is how a heater is destroyed on its first run.

Is 5 V DC safe to touch?

5 V DC is within safety extra-low voltage, so the supply itself is not a shock hazard and no protective earth is required on that account. The fire risk is unchanged: the element still produces its full power into a fault, so fusing, conductor sizing and the thermal cutoff are exactly as important as at mains voltage.

What is the maximum temperature of pt100 and pt1000 rtd sensors?

400 °C continuous, measured at the element. The limit belongs to the insulation system and not to the element alloy, so it is not a figure that can be extended by derating the power.

Does this heater need a thermostat?

Yes. It has no mechanism for limiting its own temperature — with the load removed or the control loop failed it keeps producing the same power — so the design needs a controller with a sensor to hold the set point and, separately, a bimetal thermostat or a one-shot thermal cutoff in series with the element as protection.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.