PT100 and PT1000 RTD Sensors wound for 24 V DC. The supply decides the element: 120 W at this voltage is 4.8 Ω, and the same 120 W at a tenth of the voltage would be a hundredth of the resistance in a conductor ten times heavier. This page covers the circuit, the isolation, the switching and what the construction can be built to at this supply.
The Element at 24 V DC
Two equations do all the work: P = V²/R and I = P/V. At 24 V DC, 120 W is 4.8 Ω and 5 A.
| Worked example | 120 W at 24 V DC |
|---|---|
| Element resistance, R = V²/P | 4.8 Ω |
| Current, I = P/V | 5 A |
The span matters more than the example. At 24 V DC a 20 W element is 29 Ω and a 500 W element is 1.2 Ω — a factor of twenty-five in resistance, met by changing the conductor cross-section and the length of the path, both of which are constrained by the outline.
At low voltage the difficulty is current, not insulation. 5 A wants 16 AWG rather than 22 AWG lead wire: 16 AWG is about 13 mΩ per metre, so a 2 m pair adds roughly 0.053 Ω to the circuit and dissipates 1.3 W in the leads instead of in the heater. Contact resistance at a crimp or a connector sits in series with the element in exactly the same way, and on a 1 Ω element a 20 mΩ joint is 2% of the power lost where nobody is looking for it.
The design consequence is that lead length and termination are part of the specification at low voltage. On a 5 V element the leads and the connector can account for a tenth of the total resistance, which shows up directly as a heater that never reaches temperature.
Isolation, Earthing and Safety Class
24 V DC is inside the safety extra-low voltage band, so the supply itself is not a shock hazard and the heater does not need a protective earth or double insulation on that account. The low voltage directive does not apply below 75 V DC.
What still applies is everything else: the element is at the far end of a circuit that can deliver a large current, so short-circuit protection, conductor sizing and the thermal cutoff are unchanged. Low voltage removes the shock risk, not the fire risk.
What a PT100 and PT1000 RTD Sensors Is
Platinum resistance sensors for anything that has to be accurate, repeatable and calibratable — process plates, medical warming, and any loop that gets validated.
A sensing component, specified by its tolerance class, its usable range and its response time. It has no watt density and no outline; it is fitted to a heater or to the surface the heater is warming, and where it is fitted decides what the control loop is actually controlling.
The heat leaves through whatever the component is clamped or bonded to; a sensing component adds no heat of its own and simply has to be in thermal contact with the thing it is reporting on.
| Total thickness | Component |
|---|---|
| Maximum size, one piece | Component |
| Continuous working temperature | 400 °C |
The continuous limit of 400 °C is set by the insulation system. The element alloy would run far hotter; it is never the element that decides.
Switching a DC Element
DC has no zero crossing, so a mechanical contact has to break the arc itself. A relay rated 10 A at 250 V AC may be rated 1 A or less at 30 V DC for exactly that reason, and using the AC number is how contacts weld closed — with a resistive heater on the other side, a welded contact is a heater that cannot be turned off. At 24 V DC and 5 A, use a MOSFET, a DC-rated solid state relay or a contactor with a DC rating.
PWM is the natural control method on DC, and a low frequency is right: a few hertz to a few hundred hertz is plenty for something with the thermal time constant of a heater, and it keeps the switching losses and the emissions down. There is nothing to gain from switching a thermal load at 20 kHz.
One DC-specific failure mode is worth naming: a continuous DC bias across a damp printed circuit drives electrochemical migration between adjacent tracks. It is why a silver-ink element in a humid installation is specified with a conformal barrier or reversed periodically, and why carbon ink is still used where the geometry allows it.
Attachment and Thermal Contact
A sensing component is fitted where it will read the temperature that matters: against the element for a limit device, against the load for a control device. The two positions give different numbers, and choosing the wrong one is the commonest reason a correctly built loop holds the wrong temperature.
A sensor reads its own junction, not the surface it is near. Bed it in thermal compound, clamp it, or pot it into the assembly: an air gap of a tenth of a millimetre between a thermistor and the plate it is supposed to be measuring is worth several degrees of error, and it is an error the controller cannot see.
Leads and Terminations
Termination is specified on the drawing: lead length, gauge, insulation and the connector or tag at the end of it.
The lead exit is a thermal discontinuity as well as an electrical one. The joint between a fine element and a stranded lead is the hottest point of many heaters, so it is kept out of the highest watt density zone, strain relieved, and — where the exit sits in a hot area — insulated in PTFE rather than in silicone.
Control and Protection
This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.
The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.
Which Constructions Are Wound for 24 V DC
24 V DC is not unique to this construction. In this catalogue it is also wound into:
The supply voltage is wound in at manufacture. A heater built for one voltage cannot be run on another and rated down by arithmetic — at half the voltage it makes a quarter of the power, and at twice the voltage it makes four times the power and destroys itself.
How to Specify One
This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:
- The temperature to be sensed or switched, and the tolerance the application actually needs.
- Where the component sits — against the element, in the potting, on the load, or in the airflow.
- The electrical duty: for a switching device, the voltage, the current and whether the load is AC or DC.
- Lead length, insulation and termination, and whether the component is fitted by us into a heater assembly or supplied loose.
- The standard the end product is certified to, so the component chosen is one that fits inside that approval.
Lead time: Samples 7-10 days from approved drawing; production 15-20 days.
PT100 and PT1000 RTD Sensors — Capability Table
These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.
| Parameter | Specification | Limit / note |
|---|---|---|
| Type | Thin film platinum resistance temperature detector | Nearly linear, and its characteristic is defined by standard |
| Standard | IEC 60751, class AA / A / B | Class A is u00b10.15 u00b0C at 0 u00b0C; class B is u00b10.3 u00b0C |
| Nominal resistance | 100 u03a9 (PT100) or 1000 u03a9 (PT1000) at 0 u00b0C | PT1000 is preferred on long low-voltage runs: lead resistance matters ten times less |
| Temperature range | -50 u00b0C to +400 u00b0C | The element itself; the leads and potting are usually the limit |
| Wiring | 2, 3 or 4 wire | 2-wire adds the lead resistance to the reading u2014 use 3-wire beyond a metre |
| Self heating | Keep the measuring current at or below 1 mA | A sensor heated by its own excitation current reads high, consistently |
| Encapsulation | Laminated into the heater, in a stainless probe, or surface bonded | |
| Calibration | Certificate traceable to national standards on request | Required for validated processes |
Figures are the published tolerance and rating bands of the standard sensor and control components fitted to these heaters. Sensor tolerance classes follow IEC 60751 for RTDs and IEC 60584 for thermocouples; thermostat and thermal cutoff ratings are the component manufacturers' own.