PTC Immersion and Liquid Heaters for Up to 80 °C

Which insulation systems hold Up to 80 °C continuously, what this construction is rated to, and how the Curie point is chosen to sit in that band.

PTC Immersion and Liquid Heaters are rated 150 °C continuous, a limit set by the aluminium carrier with insulating film, which covers Up to 80 °C. Comfort and condensation control: seat heating, mirror demisting, enclosure anti-condensation, battery pre-conditioning. Almost any construction reaches it, so the choice is decided by cost and thickness rather than by the temperature.

Working band
Up to 80 °C
Continuous limit, this construction
150 °C
Set by
Aluminium carrier with insulating film
Watt density
2 W/cm² free air, 10 W/cm² bonded
Total thickness
Element 1.5 mm to 3 mm; assembly to your drawing
Maximum outline, one piece
M16 to M24 thread, 60 mm to 200 mm immersion

The band is the surface temperature the heater has to hold. A PTC element settles near its Curie point under whatever cooling it has, so the Curie point is chosen for the band and the delivered power follows from the thermal path rather than from a nameplate.

PTC Immersion and Liquid Heaters — the construction this guide is about

Duty temperature decides the construction before anything else does. At up to 80 °c, ptc immersion and liquid heaters is a candidate; the sections below set out what it will hold, what has to be true for it to hold it, and what fails first when it does not.

What the Up to 80 °C Band Requires

Comfort and condensation control: seat heating, mirror demisting, enclosure anti-condensation, battery pre-conditioning. Almost any construction reaches it, so the choice is decided by cost and thickness rather than by the temperature.

BandUp to 80 °C
This construction, continuous150 °C
Limited byaluminium carrier with insulating film

The band sits comfortably inside the 150 °C ceiling, which is where a heater should be specified: the margin between the working temperature and the insulation limit is what absorbs a poor thermal path, a warm ambient and a control overshoot without shortening the life of the part.

Why the Boundary Is Where It Is

80 °C is not a material boundary at all — every construction here passes through it — so the choice inside this band is decided by cost, thickness and area rather than by temperature. That is why printed film competes here and nowhere above it.

The engineering in this band is uniformity and control, not survival: comfort heating, condensation control and battery pre-conditioning all care about holding a few degrees evenly over a large area, which is a watt density and layout problem.

What a PTC Immersion and Liquid Heaters Is

Sealed PTC assemblies for warming water, coolant and washer fluid, where a dry-run cannot be allowed to destroy the heater.

Barium titanate ceramic whose resistance rises steeply above its Curie point, so the power it draws falls as the surface approaches that temperature. The element cannot exceed the Curie point it was made to, whatever the supply or the control does. In a sealed probe the Curie point is chosen below the boiling point of the fluid, so a dry tank stops the heater rather than destroying it.

The heat leaves through the wetted wall into the fluid. That path is excellent while the fluid is there and disappears entirely when it is not, which is why the dry-run case, not the running case, sets the design.

Elementbarium titanate PTC ceramic
Insulation systemaluminium carrier with insulating film
Total thicknessElement 1.5 mm to 3 mm; assembly to your drawing
Maximum size, one pieceM16 to M24 thread, 60 mm to 200 mm immersion
Continuous working temperature150 °C

The continuous limit of 150 °C is set by aluminium carrier with insulating film. The element alloy would run far hotter; it is never the element that decides.

Which Temperature Is Being Held

Three temperatures matter and they are not the same number: the element temperature, the temperature of the surface being heated, and the ambient. A heater rated for a continuous working temperature is rated at the element — the hottest point in the assembly, and the one nothing on the outside is measuring.

The gap between element and surface is the thermal path. Bonded to metal it may be a few degrees; across an air gap, a void in the adhesive or a dry clamped joint it can be tens of degrees, and every one of them appears at the element rather than at the load.

Watt Density: the Two Figures

Two watt densities are quoted because there are two thermal situations. With nothing conducting heat away, 2 W/cm² is what the insulation survives. Bonded to a heat sink over the full outline, 10 W/cm² is. Anything in between depends on the quality of the joint, and the joint is the customer's to make.

The failure is silent and quick: the element does not know how it is mounted, so at 10 W/cm² in free air the heat simply accumulates in the insulation until it degrades. This is the single most common way these heaters are destroyed, and it happens on the first run rather than after a year.

A PTC assembly behaves differently at the limit. Deprived of its heat sink it does not run away; it reduces its own power. The consequence of a poor thermal path here is a heater that delivers well under its nameplate power, not one that destroys itself.

Control and Protection

This is the one construction here that limits its own temperature. Above the Curie point the ceramic's resistance rises steeply, the current falls, and the element settles rather than climbing — so a PTC heater cannot thermally run away even with the control shorted out.

That is a safety property, not an accuracy one. Self-regulation holds a surface somewhere near the Curie point under whatever cooling it happens to have; it does not hold a set point, and the temperature it settles at moves with airflow, with supply voltage and with the load. Where a number has to be held, a sensor and a controller are still required.

Two things still have to be designed for: the inrush, which is several times the running current while the ceramic is cold and which the supply and any switching device must tolerate, and the electrical fault case, which self-regulation does nothing about — a fuse or a current-limited supply is still the protection against a short.

Where This Construction Is the Wrong Answer

  • Do not plan on running above 150 °C. That ceiling belongs to the insulation system, not to the element alloy, and it is not a figure that derating extends — past it the insulation degrades and the dielectric strength goes with it.
  • Do not use self-regulation as a substitute for temperature control where a set point matters, and do not present it as a substitute for a fuse. It bounds the temperature; it does not hold a value and it does nothing about a short circuit.

Other Constructions That Hold Up to 80 °C

Constructions in this catalogue that will hold up to 80 °c continuously:

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • An outline drawing, or a sketch with dimensions: overall size, holes, cut-outs, radii and the lead exit position.
  • The supply voltage, and whether it is AC or DC. The element is wound for one voltage; it is not a switchable range.
  • The power required, or — better — the temperature to be reached and the mass or flow it has to be reached in. Given the second, the wattage can be calculated instead of guessed.
  • What the heater is attached to, and how. This is what decides which watt density figure applies, and it is the question a quotation cannot proceed without.
  • The ambient, and the lowest temperature the assembly must start from. A heater sized for a 20 °C start is undersized for a -30 °C one.
  • Duty cycle: continuous, intermittent, or a warm-up to a deadline. Time to temperature is a specification, not a by-product.
  • Sensor and protection: which sensor, where it goes, and which limit device is fitted in series with the element.
  • The certification the end product is built to, named on the enquiry rather than after approval.
  • Quantity and target price, because the construction that is right for fifty pieces is often not the one that is right for fifty thousand.
  • The Curie point wanted, and the airflow or thermal path the assembly will have — both decide the power the element will actually deliver.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

PTC Immersion and Liquid Heaters — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
ConstructionBarium titanate PTC ceramic, electroded on both faces, in an aluminium carrierAssembly built around the element to suit the load
Curie temperature+80 u00b0C to +150 u00b0C, selectedSelected at order u2014 it is the surface temperature ceiling and cannot be adjusted afterwards
Self-regulationPower falls to a fraction of rated as the surface reaches the Curie pointNo thermostat is required to prevent runaway; one may still be wanted for control
Element sizeM16 to M24 thread, 60 mm to 200 mm immersionStandard element footprints; assemblies to your drawing
Supply voltage12 V, 24 V, 110 V, 220 VThe same element works over a voltage band with different output
Power output2.0 W/cmu00b2 typical in still air, 10.0 W/cmu00b2 with forced airOutput is set by the airflow, not by a setting u2014 this is what self-regulating means
Inrush current3 to 8 times running current for 1 to 3 secondsThe supply and any relay or MOSFET must tolerate it
Dielectric strength1800 V AC, 1 minute, element to caseOn the assembled unit with its insulation in place
Insulation resistancegreater than 100 Mu03a9 at 500 V DC
TerminationsFaston 2.8/4.8 mm, crimp, or flying leadsChosen for the assembly temperature
LifeOver 10,000 hours at rated conditionsAgeing shows as a slow rise in cold resistance, not as sudden failure
Certifications availableUL 499, IEC/EN 60335, RoHS, REACH, CE, IATF 16949Construction level
Dry runningSurvives it: output collapses as the surface reaches the Curie pointThe single strongest argument for PTC in a liquid application
SealingO-ring or bonded seal, IP67 at the terminal endFluid compatibility is checked at quotation u2014 coolant additives attack some elastomers

Capability figures are for barium titanate PTC ceramic elements and the aluminium assemblies built around them. The defining property — that power falls steeply as the element approaches its Curie point, so surface temperature cannot run away — is inherent to the ceramic, not a feature of the control.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.

Build the Drawing

The panel above checks whether a size and a wattage can be built. This is the drawing itself: set the outline, route the heating track, place the lead wires, terminals, connector and temperature sensor, working in PET / PTC film, and turn the model to look at it. When it is right, export the 2D drawing as a PDF or a DXF and send it with your enquiry — a drawing is what a quotation for ptc immersion and liquid heaters is actually written from.

HEATING FILM DRAWING
PET / PTC Film Heater

Draw the outline, route the heating track, place the lead exits, terminals and sensor, dimension it, then export a PDF or a DXF and send it with your enquiry. Nothing here is a stock part and nothing you draw commits you to anything.

CMD

Want to compare constructions before you draw? Open the full builder, where every film family is selectable in one place.

Our facility

Held in production, not just on paper

The limits above are the ones our own lamination press, die and test lines actually hold, and every unit is tested rather than a sample. A figure is only worth quoting if it survives the process that produces it.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (IEC 60335 / UL 499 / RoHS)

ParameterSpecificationLimit / note
ConstructionBarium titanate PTC ceramic, electroded on both faces, in an aluminium carrierAssembly built around the element to suit the load
Curie temperature+80 u00b0C to +150 u00b0C, selectedSelected at order u2014 it is the surface temperature ceiling and cannot be adjusted afterwards
Self-regulationPower falls to a fraction of rated as the surface reaches the Curie pointNo thermostat is required to prevent runaway; one may still be wanted for control
Element sizeM16 to M24 thread, 60 mm to 200 mm immersionStandard element footprints; assemblies to your drawing
Supply voltage12 V, 24 V, 110 V, 220 VThe same element works over a voltage band with different output
Power output2.0 W/cmu00b2 typical in still air, 10.0 W/cmu00b2 with forced airOutput is set by the airflow, not by a setting u2014 this is what self-regulating means
Inrush current3 to 8 times running current for 1 to 3 secondsThe supply and any relay or MOSFET must tolerate it
Dielectric strength1800 V AC, 1 minute, element to caseOn the assembled unit with its insulation in place
Insulation resistancegreater than 100 Mu03a9 at 500 V DC
TerminationsFaston 2.8/4.8 mm, crimp, or flying leadsChosen for the assembly temperature
LifeOver 10,000 hours at rated conditionsAgeing shows as a slow rise in cold resistance, not as sudden failure
Certifications availableUL 499, IEC/EN 60335, RoHS, REACH, CE, IATF 16949Construction level
Dry runningSurvives it: output collapses as the surface reaches the Curie pointThe single strongest argument for PTC in a liquid application
SealingO-ring or bonded seal, IP67 at the terminal endFluid compatibility is checked at quotation u2014 coolant additives attack some elastomers

Video: PTC Immersion and Liquid Heaters for Up to 80 °C

PTC Immersion Heaters - Why Would I Need an Immersion Heater?

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

What is the maximum temperature of ptc immersion and liquid heaters?

150 °C continuous, measured at the element. The limit belongs to aluminium carrier with insulating film and not to the element alloy, so it is not a figure that can be extended by derating the power.

Does a PTC heater need a thermostat?

Not to prevent a runaway: above its Curie point the ceramic's resistance rises steeply and the power falls, so it cannot exceed that temperature whatever the control does. It does need a sensor and a controller if a set point has to be held accurately — self-regulation bounds the temperature, it does not hold a value — and it still needs a fuse, because self-regulation does nothing about an electrical fault.

How large can one piece be?

M16 to M24 thread, 60 mm to 200 mm immersion in a single piece. Larger areas are supplied as tiled zones with separate circuits, which is usually better engineering anyway: separate zones can be controlled separately, and a large single circuit has to carry the whole current at one lead exit.

Which heaters work at up to 80 °c?

Comfort and condensation control: seat heating, mirror demisting, enclosure anti-condensation, battery pre-conditioning. Almost any construction reaches it, so the choice is decided by cost and thickness rather than by the temperature.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.