220-240 V AC PTC Immersion and Liquid Heaters

How this construction is wound for 220-240 V AC, with the watt density limits in free air and bonded, the temperature the insulation holds continuously and the inrush this element draws from cold.

220-240 V AC PTC Immersion and Liquid Heaters: continuous limit 150 °C continuous, watt density 2 W/cm² free air, 10 W/cm² bonded, total thickness Element 1.5 mm to 3 mm; assembly to your drawing. At 220 V every 100 W of element power draws about 0.5 A, so the lead gauge, the connector and the switching device are sized from the wattage before anything else is decided. At mains potential the construction needs mains-rated insulation, a protective earth or double insulation, and a hi-pot and leakage test on every piece. From cold the ceramic draws several times its running current, which the supply and the switching device have to tolerate.

Supply
220-240 V AC
Element
Barium titanate PTC ceramic
Insulation
Aluminium carrier with insulating film
Continuous temperature limit
150 °C continuous
Watt density
2 W/cm² free air, 10 W/cm² bonded
Total thickness
Element 1.5 mm to 3 mm; assembly to your drawing

The element is wound to a resistance, so power follows the square of the supply: the same part on 240 V instead of 220 V makes about 19% more heat. The supply voltage is a drawing item, not a preference, and a heater wound for one voltage is not derated onto another.

PTC Immersion and Liquid Heaters — the construction this guide is about

Supply voltage page for ptc immersion and liquid heaters at 220-240 V AC. European, Chinese and most Asian mains. For the same wattage the element is a much finer, longer conductor than a 24 V one, which is what makes high-voltage low-wattage heaters the hardest to build reliably. The arithmetic, the safety class, the switching device and the capability limits are below.

The Element at 220-240 V AC

Two equations do all the work: P = V²/R and I = P/V. At 220-240 V AC, 500 W is 96.8 Ω and 2.27 A.

Worked example500 W at 220-240 V AC
Element resistance, R = V²/P96.8 Ω
Current, I = P/V2.27 A

The span matters more than the example. At 220-240 V AC a 20 W element is 242 Ω and a 500 W element is 96.8 Ω — a factor of twenty-five in resistance, met by changing the conductor cross-section and the length of the path, both of which are constrained by the outline.

At mains voltage the difficulty is the opposite one. Current is modest — 2.27 A for the worked example — but the element is a long, fine conductor, and a low-wattage heater at 220-240 V AC is the hardest thing in this catalogue to build: 20 W means 242 Ω, which is a very long track to fit inside a small outline without the pitch becoming so tight that adjacent runs interact.

Where the arithmetic will not fit the outline, the usual answers are a lower supply voltage with a small power supply behind it, several circuits in series, or a different construction entirely. What does not work is thinning the conductor further: the track becomes the fuse.

Isolation, Earthing and Safety Class

220-240 V AC is a mains supply, and the construction is built to match: mains-rated insulation, a protective earth connection or a double-insulated build, and creepage and clearance distances held between the element and any accessible surface.

Leakage current is the figure that surprises people. A large heated area behaves as a distributed capacitance to earth, so a big mains heater has a measurable leakage even when it is perfectly sound, and an RCD protecting several of them can trip on the sum. Where several elements share a circuit, allow for the total.

Dielectric withstand1800 V AC, 1 minute, element to case
Insulation resistancegreater than 100 Mu03a9 at 500 V DC

Every heater is tested to these before it ships, element to any exposed surface. A dielectric test is a pass or a fail, not a measurement — a part that passes at 2500 V is not one that may be run at 2500 V.

What a PTC Immersion and Liquid Heaters Is

Sealed PTC assemblies for warming water, coolant and washer fluid, where a dry-run cannot be allowed to destroy the heater.

Barium titanate ceramic whose resistance rises steeply above its Curie point, so the power it draws falls as the surface approaches that temperature. The element cannot exceed the Curie point it was made to, whatever the supply or the control does. In a sealed probe the Curie point is chosen below the boiling point of the fluid, so a dry tank stops the heater rather than destroying it.

The heat leaves through the wetted wall into the fluid. That path is excellent while the fluid is there and disappears entirely when it is not, which is why the dry-run case, not the running case, sets the design.

Elementbarium titanate PTC ceramic
Insulation systemaluminium carrier with insulating film
Total thicknessElement 1.5 mm to 3 mm; assembly to your drawing
Maximum size, one pieceM16 to M24 thread, 60 mm to 200 mm immersion
Continuous working temperature150 °C

The continuous limit of 150 °C is set by aluminium carrier with insulating film. The element alloy would run far hotter; it is never the element that decides.

Switching an AC Element

AC switching has a zero crossing to hide behind. A zero-cross solid state relay makes and breaks at the crossing, which all but removes the switching transient and the conducted emissions that go with it — worth having on any installation that also has to pass an EMC test.

Control by burst firing — whole cycles on, whole cycles off, over a period of a second or more — rather than by phase angle. Burst firing generates almost no harmonics; phase angle control chops the waveform and is the reason a heater ends up in the EMC report at all. A heater has enough thermal inertia that a one-second period is invisible at the surface.

Size the relay for the inrush, not the running current, and heatsink it: a triac or SSR drops around one volt per amp of load, and that is real power to be got rid of inside the panel.

A PTC assembly adds an inrush that the switching device has to survive: cold, the ceramic draws several times its running current until it warms into its regulating region. Rate the device for the cold current, not the hot one.

Watt Density: the Two Figures

Watt density, not wattage, is what the construction is limited by. 2 W/cm² unbonded and 10 W/cm² bonded to metal are the limits for this build — so if the wattage is fixed by the duty, the area is what has to move.

Where the required power will not fit into the available area at the free-air figure, the answer is a better thermal path rather than a thinner margin: bond the whole face down, or add a spreader plate. On 150 cm² the difference is roughly 3 W against 15 W, which is usually the whole argument.

A PTC assembly behaves differently at the limit. Deprived of its heat sink it does not run away; it reduces its own power. The consequence of a poor thermal path here is a heater that delivers well under its nameplate power, not one that destroys itself.

Attachment and Thermal Contact

The heater screws into a boss or a tank wall on its own thread and seals there. The sealing face and the thread form are on the drawing; so is the immersion depth, because the element must stay covered at the lowest working level in the tank.

The joint between the heated surface and the load carries every watt the element makes. Fill it: an interface pad, a thin film of thermal grease or a bonded assembly. Two dry surfaces bolted together are a thermal resistance, and that resistance appears as element temperature.

Control and Protection

This is the one construction here that limits its own temperature. Above the Curie point the ceramic's resistance rises steeply, the current falls, and the element settles rather than climbing — so a PTC heater cannot thermally run away even with the control shorted out.

That is a safety property, not an accuracy one. Self-regulation holds a surface somewhere near the Curie point under whatever cooling it happens to have; it does not hold a set point, and the temperature it settles at moves with airflow, with supply voltage and with the load. Where a number has to be held, a sensor and a controller are still required.

Two things still have to be designed for: the inrush, which is several times the running current while the ceramic is cold and which the supply and any switching device must tolerate, and the electrical fault case, which self-regulation does nothing about — a fuse or a current-limited supply is still the protection against a short.

Which Constructions Are Wound for 220-240 V AC

220-240 V AC is not unique to this construction. In this catalogue it is also wound into:

The supply voltage is wound in at manufacture. A heater built for one voltage cannot be run on another and rated down by arithmetic — at half the voltage it makes a quarter of the power, and at twice the voltage it makes four times the power and destroys itself.

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • An outline drawing, or a sketch with dimensions: overall size, holes, cut-outs, radii and the lead exit position.
  • The supply voltage, and whether it is AC or DC. The element is wound for one voltage; it is not a switchable range.
  • The power required, or — better — the temperature to be reached and the mass or flow it has to be reached in. Given the second, the wattage can be calculated instead of guessed.
  • What the heater is attached to, and how. This is what decides which watt density figure applies, and it is the question a quotation cannot proceed without.
  • The ambient, and the lowest temperature the assembly must start from. A heater sized for a 20 °C start is undersized for a -30 °C one.
  • Duty cycle: continuous, intermittent, or a warm-up to a deadline. Time to temperature is a specification, not a by-product.
  • Sensor and protection: which sensor, where it goes, and which limit device is fitted in series with the element.
  • The certification the end product is built to, named on the enquiry rather than after approval.
  • Quantity and target price, because the construction that is right for fifty pieces is often not the one that is right for fifty thousand.
  • The Curie point wanted, and the airflow or thermal path the assembly will have — both decide the power the element will actually deliver.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

PTC Immersion and Liquid Heaters — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
ConstructionBarium titanate PTC ceramic, electroded on both faces, in an aluminium carrierAssembly built around the element to suit the load
Curie temperature+80 u00b0C to +150 u00b0C, selectedSelected at order u2014 it is the surface temperature ceiling and cannot be adjusted afterwards
Self-regulationPower falls to a fraction of rated as the surface reaches the Curie pointNo thermostat is required to prevent runaway; one may still be wanted for control
Element sizeM16 to M24 thread, 60 mm to 200 mm immersionStandard element footprints; assemblies to your drawing
Supply voltage12 V, 24 V, 110 V, 220 VThe same element works over a voltage band with different output
Power output2.0 W/cmu00b2 typical in still air, 10.0 W/cmu00b2 with forced airOutput is set by the airflow, not by a setting u2014 this is what self-regulating means
Inrush current3 to 8 times running current for 1 to 3 secondsThe supply and any relay or MOSFET must tolerate it
Dielectric strength1800 V AC, 1 minute, element to caseOn the assembled unit with its insulation in place
Insulation resistancegreater than 100 Mu03a9 at 500 V DC
TerminationsFaston 2.8/4.8 mm, crimp, or flying leadsChosen for the assembly temperature
LifeOver 10,000 hours at rated conditionsAgeing shows as a slow rise in cold resistance, not as sudden failure
Certifications availableUL 499, IEC/EN 60335, RoHS, REACH, CE, IATF 16949Construction level
Dry runningSurvives it: output collapses as the surface reaches the Curie pointThe single strongest argument for PTC in a liquid application
SealingO-ring or bonded seal, IP67 at the terminal endFluid compatibility is checked at quotation u2014 coolant additives attack some elastomers

Capability figures are for barium titanate PTC ceramic elements and the aluminium assemblies built around them. The defining property — that power falls steeply as the element approaches its Curie point, so surface temperature cannot run away — is inherent to the ceramic, not a feature of the control.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.

Build the Drawing

The panel above checks whether a size and a wattage can be built. This is the drawing itself: set the outline, route the heating track, place the lead wires, terminals, connector and temperature sensor, working in PET / PTC film, and turn the model to look at it. When it is right, export the 2D drawing as a PDF or a DXF and send it with your enquiry — a drawing is what a quotation for ptc immersion and liquid heaters is actually written from.

HEATING FILM DRAWING
PET / PTC Film Heater

Draw the outline, route the heating track, place the lead exits, terminals and sensor, dimension it, then export a PDF or a DXF and send it with your enquiry. Nothing here is a stock part and nothing you draw commits you to anything.

CMD

Want to compare constructions before you draw? Open the full builder, where every film family is selectable in one place.

Our facility

Where these heaters are actually made

Circuit layout, element preparation, lamination and vulcanising, die cutting and lead attachment all happen under one roof, so a watt density limit and a temperature ceiling are set by processes we control and can evidence, not by whichever supplier had stock.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (IEC 60335 / UL 499 / RoHS)

ParameterSpecificationLimit / note
ConstructionBarium titanate PTC ceramic, electroded on both faces, in an aluminium carrierAssembly built around the element to suit the load
Curie temperature+80 u00b0C to +150 u00b0C, selectedSelected at order u2014 it is the surface temperature ceiling and cannot be adjusted afterwards
Self-regulationPower falls to a fraction of rated as the surface reaches the Curie pointNo thermostat is required to prevent runaway; one may still be wanted for control
Element sizeM16 to M24 thread, 60 mm to 200 mm immersionStandard element footprints; assemblies to your drawing
Supply voltage12 V, 24 V, 110 V, 220 VThe same element works over a voltage band with different output
Power output2.0 W/cmu00b2 typical in still air, 10.0 W/cmu00b2 with forced airOutput is set by the airflow, not by a setting u2014 this is what self-regulating means
Inrush current3 to 8 times running current for 1 to 3 secondsThe supply and any relay or MOSFET must tolerate it
Dielectric strength1800 V AC, 1 minute, element to caseOn the assembled unit with its insulation in place
Insulation resistancegreater than 100 Mu03a9 at 500 V DC
TerminationsFaston 2.8/4.8 mm, crimp, or flying leadsChosen for the assembly temperature
LifeOver 10,000 hours at rated conditionsAgeing shows as a slow rise in cold resistance, not as sudden failure
Certifications availableUL 499, IEC/EN 60335, RoHS, REACH, CE, IATF 16949Construction level
Dry runningSurvives it: output collapses as the surface reaches the Curie pointThe single strongest argument for PTC in a liquid application
SealingO-ring or bonded seal, IP67 at the terminal endFluid compatibility is checked at quotation u2014 coolant additives attack some elastomers

Video: 220-240 V AC PTC Immersion and Liquid Heaters

Best Small Heater on Amazon? | Aottop 1200W PTC Ceramic Heater Test

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

How much current does a heater draw at 220-240 V AC?

I = P/V. At 220-240 V AC a 100 W heater draws 0.45 A and its element is 484 Ω; a 500 W heater draws 2.27 A and is 96.8 Ω. The current is what sizes the lead wire, the connector and the switching device, and at low voltage it is the whole design problem.

Can a 220-240 V AC heater be run on another voltage?

No. The element is wound for one voltage at manufacture. Power goes with the square of the supply, so at half the voltage it makes a quarter of the power and at twice the voltage it makes four times the power — which is how a heater is destroyed on its first run.

What isolation does a 220-240 V AC heater need?

Mains-rated insulation, a protective earth connection or a double-insulated construction, and creepage and clearance distances held between the element and any accessible surface. The construction is dielectric tested element-to-surface before it ships, and the test is a pass or fail rather than a working rating.

What watt density can ptc immersion and liquid heaters run at?

2 W/cm² with nothing conducting the heat away, and 10 W/cm² bonded over its whole area to metal. The two figures describe two different installations, not a range to choose from: a heater specified at 10 W/cm² and then run in free air reaches its insulation limit within minutes.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.