Temperature Sensing & Control · IEC 60751 / IEC 60730 / RoHS

RoHS & REACH PT100 and PT1000 RTD Sensors

What RoHS & REACH fixes, what it deliberately leaves to another document, and how it is evidenced on a heater built to a customer drawing.

Restriction of hazardous substances in the materials and the solder, and declaration of substances of very high concern. Required for anything sold into the EU.

Standard
RoHS & REACH
What it does not cover
A compliance declaration, not a safety approval.
Construction
PT100 and PT1000 RTD Sensors
Built and tested to
IEC 60751 / IEC 60730 / RoHS
Continuous temperature limit
400 °C continuous

A construction is built and tested to a standard. A heater made to your outline has no certified part number of its own, so the approval sits with the end product and with the file you hold — what this factory supplies is the construction, the materials and the test records that let that file be assembled.

PT100 and PT1000 RTD Sensors — the construction this guide is about

RoHS & REACH as it applies to pt100 and pt1000 rtd sensors: what the document covers, what it deliberately leaves to someone else, and how a made-to-drawing heater is certified at all — which is not the same question as whether a part number is approved.

RoHS & REACH — Scope

Restriction of hazardous substances in the materials and the solder, and declaration of substances of very high concern. Required for anything sold into the EU.

What RoHS & REACH Does Not Cover

A compliance declaration, not a safety approval.

This is the division of labour to carry away from any heating standard: safety standards decide whether the part can hurt somebody, and say nothing about whether it holds a temperature, lasts five years or matches the last batch. Performance is a specification you write; safety is one the standard writes.

How a Made-to-Drawing Heater Is Certified

A construction is built and tested to a standard. The insulation system, the creepage and clearance distances, the earthing, the lead anchorage, the temperature under fault and the marking are what the test covers — and all of those are properties of the construction rather than of the outline it is die-cut to.

So a custom outline does not have a certificate of its own, and no supplier can honestly hand you one. What is available is the construction file: the standard the build is tested to, the materials list with their own ratings, and the test reports. That is what an approvals engineer needs, and it is what the end product's own certification is built on.

The practical consequence: name RoHS & REACH on the enquiry, not after approval. A construction chosen for cost and then asked to pass a standard afterwards usually has to be rebuilt, because the insulation thickness, the creepage distances and the lead anchorage are decided at design time and are not adjustable later.

What a PT100 and PT1000 RTD Sensors Is

Platinum resistance sensors for anything that has to be accurate, repeatable and calibratable — process plates, medical warming, and any loop that gets validated.

A sensing component, specified by its tolerance class, its usable range and its response time. It has no watt density and no outline; it is fitted to a heater or to the surface the heater is warming, and where it is fitted decides what the control loop is actually controlling.

The heat leaves through whatever the component is clamped or bonded to; a sensing component adds no heat of its own and simply has to be in thermal contact with the thing it is reporting on.

Total thicknessComponent
Maximum size, one pieceComponent
Continuous working temperature400 °C

The continuous limit of 400 °C is set by the insulation system. The element alloy would run far hotter; it is never the element that decides.

The Other Standards This Construction Is Built To

A heater is rarely governed by one document. This construction is also built and tested to:

Safety, materials, substances and quality system are four separate questions with four separate documents behind them. A part can satisfy all four and still be the wrong heater for the duty, which is what the rest of this page is about.

Control and Protection

This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.

The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.

Leads and Terminations

Termination is specified on the drawing: lead length, gauge, insulation and the connector or tag at the end of it.

The lead exit is a thermal discontinuity as well as an electrical one. The joint between a fine element and a stranded lead is the hottest point of many heaters, so it is kept out of the highest watt density zone, strain relieved, and — where the exit sits in a hot area — insulated in PTFE rather than in silicone.

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • The temperature to be sensed or switched, and the tolerance the application actually needs.
  • Where the component sits — against the element, in the potting, on the load, or in the airflow.
  • The electrical duty: for a switching device, the voltage, the current and whether the load is AC or DC.
  • Lead length, insulation and termination, and whether the component is fitted by us into a heater assembly or supplied loose.
  • The standard the end product is certified to, so the component chosen is one that fits inside that approval.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

PT100 and PT1000 RTD Sensors — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
TypeThin film platinum resistance temperature detectorNearly linear, and its characteristic is defined by standard
StandardIEC 60751, class AA / A / BClass A is u00b10.15 u00b0C at 0 u00b0C; class B is u00b10.3 u00b0C
Nominal resistance100 u03a9 (PT100) or 1000 u03a9 (PT1000) at 0 u00b0CPT1000 is preferred on long low-voltage runs: lead resistance matters ten times less
Temperature range-50 u00b0C to +400 u00b0CThe element itself; the leads and potting are usually the limit
Wiring2, 3 or 4 wire2-wire adds the lead resistance to the reading u2014 use 3-wire beyond a metre
Self heatingKeep the measuring current at or below 1 mAA sensor heated by its own excitation current reads high, consistently
EncapsulationLaminated into the heater, in a stainless probe, or surface bonded
CalibrationCertificate traceable to national standards on requestRequired for validated processes

Figures are the published tolerance and rating bands of the standard sensor and control components fitted to these heaters. Sensor tolerance classes follow IEC 60751 for RTDs and IEC 60584 for thermocouples; thermostat and thermal cutoff ratings are the component manufacturers' own.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.
Our facility

Where these heaters are actually made

Circuit layout, element preparation, lamination and vulcanising, die cutting and lead attachment all happen under one roof, so a watt density limit and a temperature ceiling are set by processes we control and can evidence, not by whichever supplier had stock.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (IEC 60751 / IEC 60730 / RoHS)

ParameterSpecificationLimit / note
TypeThin film platinum resistance temperature detectorNearly linear, and its characteristic is defined by standard
StandardIEC 60751, class AA / A / BClass A is u00b10.15 u00b0C at 0 u00b0C; class B is u00b10.3 u00b0C
Nominal resistance100 u03a9 (PT100) or 1000 u03a9 (PT1000) at 0 u00b0CPT1000 is preferred on long low-voltage runs: lead resistance matters ten times less
Temperature range-50 u00b0C to +400 u00b0CThe element itself; the leads and potting are usually the limit
Wiring2, 3 or 4 wire2-wire adds the lead resistance to the reading u2014 use 3-wire beyond a metre
Self heatingKeep the measuring current at or below 1 mAA sensor heated by its own excitation current reads high, consistently
EncapsulationLaminated into the heater, in a stainless probe, or surface bonded
CalibrationCertificate traceable to national standards on requestRequired for validated processes

Video: RoHS & REACH PT100 and PT1000 RTD Sensors

Sensorelement KTY 81 210 - TEST

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

What is the maximum temperature of pt100 and pt1000 rtd sensors?

400 °C continuous, measured at the element. The limit belongs to the insulation system and not to the element alloy, so it is not a figure that can be extended by derating the power.

Does this heater need a thermostat?

Yes. It has no mechanism for limiting its own temperature — with the load removed or the control loop failed it keeps producing the same power — so the design needs a controller with a sensor to hold the set point and, separately, a bimetal thermostat or a one-shot thermal cutoff in series with the element as protection.

How large can one piece be?

Component in a single piece. Larger areas are supplied as tiled zones with separate circuits, which is usually better engineering anyway: separate zones can be controlled separately, and a large single circuit has to carry the whole current at one lead exit.

Is this heater RoHS & REACH approved?

The construction is built and tested to RoHS & REACH; the outline is yours, and a made-to-drawing outline does not carry a certificate of its own. What is available is the construction file — the standard the build is tested to, the material ratings and the test reports — which is what your own product approval is built on.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.