Skip to content
Thick Film Heaters · UL 499 / IEC 60335 / RoHS

Stainless Steel Thick Film Heaters for 80-120 °C

Which insulation systems hold 80 °C to 120 °C continuously, what this construction is rated to, and the control and cut-out that hold the surface there.

Stainless Steel Thick Film Heaters are rated 400 °C continuous, a limit set by the fired glass dielectric on the substrate, which covers 80 °C to 120 °C. Battery operating windows, incubators, fluid warming and display heating. The upper limit of PET film, and the band where a low-cost printed heater stops being a candidate.

Working band
80 °C to 120 °C
Continuous limit, this construction
400 °C
Set by
Fired glass dielectric on the substrate
Watt density
5 W/cm² free air, 50 W/cm² bonded
Total thickness
1.5 mm to 4 mm total
Maximum outline, one piece
200 x 400 mm

The band is the temperature the heated surface has to hold, not the temperature the element reaches. The element always runs hotter, by an amount the watt density and the thermal path decide, so the cut-out is set against the element and not against the load.

Stainless Steel Thick Film Heaters — the construction this guide is about

Duty temperature decides the construction before anything else does. At 80 °c to 120 °c, stainless steel thick film heaters is a candidate; the sections below set out what it will hold, what has to be true for it to hold it, and what fails first when it does not.

What the 80 °C to 120 °C Band Requires

Battery operating windows, incubators, fluid warming and display heating. The upper limit of PET film, and the band where a low-cost printed heater stops being a candidate.

Band80 °C to 120 °C
This construction, continuous400 °C
Limited byfired glass dielectric on the substrate

The band sits comfortably inside the 400 °C ceiling, which is where a heater should be specified: the margin between the working temperature and the insulation limit is what absorbs a poor thermal path, a warm ambient and a control overshoot without shortening the life of the part.

Why the Boundary Is Where It Is

120 °C is where PET film stops. The polyester softens from about 130 °C and loses its dielectric strength as it softens, so the margin between working temperature and failure is thin — and a failure here is an electrical one, not a cosmetic one.

This is therefore the last band in which the cheapest thin heater is a candidate. Above it, the construction changes to silicone or polyimide, and the cost per square metre changes with it.

What a Stainless Steel Thick Film Heaters Is

Resistor tracks fired onto 304 or 316 stainless: the heated surface is the pressure boundary itself, so there is no gasket, no interface and nothing to conduct across.

Dielectric and resistor pastes screen printed onto stainless steel or alumina and fired at around 850 °C, then laser trimmed to resistance. There is no separate element and no interface: the heated surface is the substrate itself. Rigid: the fired layers will not tolerate flexing, and a dented substrate is a scrapped heater.

The heat leaves through a clamped joint, and a clamped joint is only as good as the pressure and the flatness behind it. A thermal interface material or a thin film of thermal grease fills the gaps that machining leaves; without one, contact happens at the high spots and the element runs hotter than the plate it is bolted to.

Elementfired resistor paste, laser trimmed
Insulation systemfired glass dielectric on the substrate
Total thickness1.5 mm to 4 mm total
Maximum size, one piece200 x 400 mm
Continuous working temperature400 °C

The continuous limit of 400 °C is set by fired glass dielectric on the substrate. The element alloy would run far hotter; it is never the element that decides.

Which Temperature Is Being Held

Three temperatures matter and they are not the same number: the element temperature, the temperature of the surface being heated, and the ambient. A heater rated for a continuous working temperature is rated at the element — the hottest point in the assembly, and the one nothing on the outside is measuring.

The gap between element and surface is the thermal path. Bonded to metal it may be a few degrees; across an air gap, a void in the adhesive or a dry clamped joint it can be tens of degrees, and every one of them appears at the element rather than at the load.

Which is why sensor position is a drawing item. A sensor laminated into the heater protects the heater; a sensor on the load controls the load. Assemblies that have to do both carry two: a control sensor where the process is, and a limit device against the element.

Watt Density: the Two Figures

Two watt densities are quoted because there are two thermal situations. With nothing conducting heat away, 5 W/cm² is what the insulation survives. Bonded to a heat sink over the full outline, 50 W/cm² is. Anything in between depends on the quality of the joint, and the joint is the customer's to make.

The failure is silent and quick: the element does not know how it is mounted, so at 50 W/cm² in free air the heat simply accumulates in the insulation until it degrades. This is the single most common way these heaters are destroyed, and it happens on the first run rather than after a year.

Thick film reaches these densities because the heated surface is the substrate — there is no interface between element and load to conduct across. That is also why dry-run protection is not optional: with the fluid gone, so is the entire thermal path, and the fired layers reach their limit in seconds rather than minutes.

Control and Protection

This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.

The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.

On a fluid heater the limit device belongs on the substrate, close to the resistor, not downstream in the water. Downstream is where the temperature has already gone wrong; the substrate is where it goes wrong first, and at these watt densities the interval between the two is short.

Sensors can be built into the part: NTC thermistor, PT100 or PT1000 RTD, or a K-type thermocouple, fitted under the same insulation and tested with the heater as one assembly. A sensor laminated into the heater reads the heater; a sensor on the load reads the load. Both are legitimate, and the drawing has to say which is wanted.

Where This Construction Is the Wrong Answer

  • Do not plan on running above 400 °C. That ceiling belongs to the insulation system, not to the element alloy, and it is not a figure that derating extends — past it the insulation degrades and the dielectric strength goes with it.
  • Do not flex the substrate, clamp it unevenly, or accept a dented one. The fired glass dielectric is a brittle layer bonded to metal, and it cracks before anything visible happens to the plate.

Other Constructions That Hold 80 °C to 120 °C

Constructions in this catalogue that will hold 80 °c to 120 °c continuously:

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • An outline drawing, or a sketch with dimensions: overall size, holes, cut-outs, radii and the lead exit position.
  • The supply voltage, and whether it is AC or DC. The element is wound for one voltage; it is not a switchable range.
  • The power required, or — better — the temperature to be reached and the mass or flow it has to be reached in. Given the second, the wattage can be calculated instead of guessed.
  • What the heater is attached to, and how. This is what decides which watt density figure applies, and it is the question a quotation cannot proceed without.
  • The ambient, and the lowest temperature the assembly must start from. A heater sized for a 20 °C start is undersized for a -30 °C one.
  • Duty cycle: continuous, intermittent, or a warm-up to a deadline. Time to temperature is a specification, not a by-product.
  • Sensor and protection: which sensor, where it goes, and which limit device is fitted in series with the element.
  • The certification the end product is built to, named on the enquiry rather than after approval.
  • Quantity and target price, because the construction that is right for fifty pieces is often not the one that is right for fifty thousand.
  • The fluid, its flow rate and its inlet temperature, and how a dry-run condition is detected in your system.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

Stainless Steel Thick Film Heaters — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
ConstructionGlass dielectric and resistor pastes screen printed and fired onto the substrate, then laser trimmed to resistanceFired, bonded or encapsulated as a single assembly
Substrate304 or 316 stainless steel, 0.8 mm to 3 mmThe substrate carries the heat and the mechanical load
Thickness1.5 mm to 4 mm totalSubstrate plus element system
Maximum size, one piece200 x 400 mmLimited by the firing or curing fixture
Dimensional toleranceu00b10.2 mm on the substrate, u00b10.1 mm on printed featuresOn the machined substrate
Supply voltage12 V DC to 400 V ACCircuit is designed for the ordered voltage
Resistance toleranceu00b110% standard, u00b15% selectedThick film resistors are laser trimmed where a tighter band is required
Watt density5 W/cmu00b2 typical, 50 W/cmu00b2 maximum in a wetted applicationAchievable because the heat is generated in the surface being cooled
Maximum working temperature+400 u00b0C at the element systemOf the element system; the substrate itself tolerates more
Dielectric strength2500 V AC, 1 minuteOne minute, circuit to substrate
Insulation resistancegreater than 100 Mu03a9 at 500 V DCAt 500 V DC
TerminationsWelded tabs, crimp terminals or soldered leads depending on temperatureSoldered, welded or crimped as the temperature allows
MountingBolted, brazed or welded into the assembly; flatness of the mating face is criticalFlatness of the mating face matters more than clamping force
Sensor and control optionsPrinted PTC or NTC track, or a bonded thermocoupleIntegrated into the same firing or bonded to the substrate
Certifications availableUL 499, IEC/EN 60335, RoHS, REACH, CEConstruction level
Why stainlessThe wetted face is the substrate, so the water sees steel and the element sees no interfaceThis is the reason a thick film heater outperforms a tubular element in a flow heater
Thermal responseUnder 1 second to full outputAlmost no thermal mass between the resistor and the fluid

Capability figures are this factory's process limits for fired thick film construction. Watt densities far above any flexible heater are achievable because the resistor is printed directly onto the surface being cooled — there is no interface and no adhesive in the heat path.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.

Build the Drawing

The panel above checks whether a size and a wattage can be built. This is the drawing itself: set the outline, route the heating track, place the lead wires, terminals, connector and temperature sensor, working in metal-clad thick film, and turn the model to look at it. When it is right, export the 2D drawing as a PDF or a DXF and send it with your enquiry — a drawing is what a quotation for stainless steel thick film heaters is actually written from.

HEATING FILM DRAWING
Aluminium / Metal-Clad Thick Film Heater

Draw the outline, route the heating track, place the lead exits, terminals and sensor, dimension it, then export a PDF or a DXF and send it with your enquiry. Nothing here is a stock part and nothing you draw commits you to anything.

CMD

Want to compare constructions before you draw? Open the full builder, where every film family is selectable in one place.

Our facility

Where these heaters are actually made

Circuit layout, element preparation, lamination and vulcanising, die cutting and lead attachment all happen under one roof, so a watt density limit and a temperature ceiling are set by processes we control and can evidence, not by whichever supplier had stock.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (UL 499 / IEC 60335 / RoHS)

ParameterSpecificationLimit / note
ConstructionGlass dielectric and resistor pastes screen printed and fired onto the substrate, then laser trimmed to resistanceFired, bonded or encapsulated as a single assembly
Substrate304 or 316 stainless steel, 0.8 mm to 3 mmThe substrate carries the heat and the mechanical load
Thickness1.5 mm to 4 mm totalSubstrate plus element system
Maximum size, one piece200 x 400 mmLimited by the firing or curing fixture
Dimensional toleranceu00b10.2 mm on the substrate, u00b10.1 mm on printed featuresOn the machined substrate
Supply voltage12 V DC to 400 V ACCircuit is designed for the ordered voltage
Resistance toleranceu00b110% standard, u00b15% selectedThick film resistors are laser trimmed where a tighter band is required
Watt density5 W/cmu00b2 typical, 50 W/cmu00b2 maximum in a wetted applicationAchievable because the heat is generated in the surface being cooled
Maximum working temperature+400 u00b0C at the element systemOf the element system; the substrate itself tolerates more
Dielectric strength2500 V AC, 1 minuteOne minute, circuit to substrate
Insulation resistancegreater than 100 Mu03a9 at 500 V DCAt 500 V DC
TerminationsWelded tabs, crimp terminals or soldered leads depending on temperatureSoldered, welded or crimped as the temperature allows
MountingBolted, brazed or welded into the assembly; flatness of the mating face is criticalFlatness of the mating face matters more than clamping force
Sensor and control optionsPrinted PTC or NTC track, or a bonded thermocoupleIntegrated into the same firing or bonded to the substrate
Certifications availableUL 499, IEC/EN 60335, RoHS, REACH, CEConstruction level
Why stainlessThe wetted face is the substrate, so the water sees steel and the element sees no interfaceThis is the reason a thick film heater outperforms a tubular element in a flow heater
Thermal responseUnder 1 second to full outputAlmost no thermal mass between the resistor and the fluid

Video: Stainless Steel Thick Film Heaters for 80-120 °C

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

What is the maximum temperature of stainless steel thick film heaters?

400 °C continuous, measured at the element. The limit belongs to fired glass dielectric on the substrate and not to the element alloy, so it is not a figure that can be extended by derating the power.

Does this heater need a thermostat?

Yes. It has no mechanism for limiting its own temperature — with the load removed or the control loop failed it keeps producing the same power — so the design needs a controller with a sensor to hold the set point and, separately, a bimetal thermostat or a one-shot thermal cutoff in series with the element as protection.

Is there a part number I can order?

No — these are made to your drawing, so a part number would describe something that was never built. A quotation needs the outline, the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. The table on this page is what the factory can hold, not a stock list.

How large can one piece be?

200 x 400 mm in a single piece. Larger areas are supplied as tiled zones with separate circuits, which is usually better engineering anyway: separate zones can be controlled separately, and a large single circuit has to carry the whole current at one lead exit.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.