Type K and Type J Thermocouples for 120-150 °C

Which insulation systems hold 120 °C to 150 °C continuously, what this construction is rated to, and the control and cut-out that hold the surface there.

Type K and Type J Thermocouples are rated 400 °C continuous, which covers 120 °C to 150 °C. Process and platen heating, adhesive curing, epoxy-encapsulated plates at their limit. Silicone and polyimide are comfortable here; the encapsulant, not the element, is usually what constrains the design.

Working band
120 °C to 150 °C
Continuous limit, this construction
400 °C
Total thickness
Component
Maximum outline, one piece
Component

The band is the temperature the heated surface has to hold, not the temperature the element reaches. The element always runs hotter, by an amount the watt density and the thermal path decide, so the cut-out is set against the element and not against the load.

Type K and Type J Thermocouples — the construction this guide is about

Type K and Type J Thermocouples in the 120 °c to 150 °c band. Process and platen heating, adhesive curing, epoxy-encapsulated plates at their limit. Silicone and polyimide are comfortable here; the encapsulant, not the element, is usually what constrains the design. The construction is rated 400 °C continuous, so this band sits inside its ceiling — and where a band sits relative to the ceiling is the whole of the selection argument.

What the 120 °C to 150 °C Band Requires

Process and platen heating, adhesive curing, epoxy-encapsulated plates at their limit. Silicone and polyimide are comfortable here; the encapsulant, not the element, is usually what constrains the design.

Band120 °C to 150 °C
This construction, continuous400 °C

The band sits comfortably inside the 400 °C ceiling, which is where a heater should be specified: the margin between the working temperature and the insulation limit is what absorbs a poor thermal path, a warm ambient and a control overshoot without shortening the life of the part.

Why the Boundary Is Where It Is

150 °C is the ceiling of filled epoxy, and on an encapsulated plate the encapsulant fails before either the element or the plate is troubled. It is also roughly where acrylic pressure-sensitive adhesives give up, which matters on any heater that is held on by its own adhesive rather than clamped.

Silicone and polyimide are comfortable through this band with 50 °C of margin in hand; the constraint is usually the bonding system, not the heater.

What a Type K and Type J Thermocouples Is

For temperatures beyond the range of any resistance sensor, and for the fast, robust measurement a thick film or mica heater needs.

A sensing component, specified by its tolerance class, its usable range and its response time. It has no watt density and no outline; it is fitted to a heater or to the surface the heater is warming, and where it is fitted decides what the control loop is actually controlling.

The heat leaves through whatever the component is clamped or bonded to; a sensing component adds no heat of its own and simply has to be in thermal contact with the thing it is reporting on.

Total thicknessComponent
Maximum size, one pieceComponent
Continuous working temperature400 °C

The continuous limit of 400 °C is set by the insulation system. The element alloy would run far hotter; it is never the element that decides.

Which Temperature Is Being Held

Three temperatures matter and they are not the same number: the element temperature, the temperature of the surface being heated, and the ambient. A heater rated for a continuous working temperature is rated at the element — the hottest point in the assembly, and the one nothing on the outside is measuring.

The gap between element and surface is the thermal path. Bonded to metal it may be a few degrees; across an air gap, a void in the adhesive or a dry clamped joint it can be tens of degrees, and every one of them appears at the element rather than at the load.

Attachment and Thermal Contact

A sensing component is fitted where it will read the temperature that matters: against the element for a limit device, against the load for a control device. The two positions give different numbers, and choosing the wrong one is the commonest reason a correctly built loop holds the wrong temperature.

A sensor reads its own junction, not the surface it is near. Bed it in thermal compound, clamp it, or pot it into the assembly: an air gap of a tenth of a millimetre between a thermistor and the plate it is supposed to be measuring is worth several degrees of error, and it is an error the controller cannot see.

Control and Protection

This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.

The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.

How This Construction Fails

  • Loss of the control loop. An open-circuit sensor, a welded relay contact or a controller in manual leaves the element at full power with nothing watching it — the case the series thermal cutoff exists for, and the reason it must not be omitted to save a part.
  • Measuring the wrong thing. A sensor in the air near a heated plate reports the air, and the loop holds the air where the specification wanted the plate. Nothing in the instrument can detect this.

Other Constructions That Hold 120 °C to 150 °C

Constructions in this catalogue that will hold 120 °c to 150 °c continuously:

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • The temperature to be sensed or switched, and the tolerance the application actually needs.
  • Where the component sits — against the element, in the potting, on the load, or in the airflow.
  • The electrical duty: for a switching device, the voltage, the current and whether the load is AC or DC.
  • Lead length, insulation and termination, and whether the component is fitted by us into a heater assembly or supplied loose.
  • The standard the end product is certified to, so the component chosen is one that fits inside that approval.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

Type K and Type J Thermocouples — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
Type KNickel-chromium / nickel-alumel, -200 u00b0C to +1200 u00b0CThe general purpose thermocouple
Type JIron / constantan, 0 u00b0C to +750 u00b0CHigher output than K, but the iron leg corrodes in moist air
StandardIEC 60584 class 1 or class 2Class 1 is u00b11.5 u00b0C or u00b10.004|t| for type K
JunctionGrounded, ungrounded or exposedUngrounded avoids earth loops; exposed is fastest and least protected
Response timeUnder 1 second exposed, 2 to 10 seconds sheathed
Cold junctionCompensation required at the instrumentA thermocouple measures a difference, not a temperature u2014 this is where most errors come from
Extension cableMatching type, correct polarityCopper extension wire silently destroys the measurement
Sheath304 or 316 stainless, 1 mm to 6 mm diameter

Figures are the published tolerance and rating bands of the standard sensor and control components fitted to these heaters. Sensor tolerance classes follow IEC 60751 for RTDs and IEC 60584 for thermocouples; thermostat and thermal cutoff ratings are the component manufacturers' own.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.
Our facility

Held in production, not just on paper

The limits above are the ones our own lamination press, die and test lines actually hold, and every unit is tested rather than a sample. A figure is only worth quoting if it survives the process that produces it.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (IEC 60584 / IEC 60730 / RoHS)

ParameterSpecificationLimit / note
Type KNickel-chromium / nickel-alumel, -200 u00b0C to +1200 u00b0CThe general purpose thermocouple
Type JIron / constantan, 0 u00b0C to +750 u00b0CHigher output than K, but the iron leg corrodes in moist air
StandardIEC 60584 class 1 or class 2Class 1 is u00b11.5 u00b0C or u00b10.004|t| for type K
JunctionGrounded, ungrounded or exposedUngrounded avoids earth loops; exposed is fastest and least protected
Response timeUnder 1 second exposed, 2 to 10 seconds sheathed
Cold junctionCompensation required at the instrumentA thermocouple measures a difference, not a temperature u2014 this is where most errors come from
Extension cableMatching type, correct polarityCopper extension wire silently destroys the measurement
Sheath304 or 316 stainless, 1 mm to 6 mm diameter

Video: Type K and Type J Thermocouples for 120-150 °C

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

How large can one piece be?

Component in a single piece. Larger areas are supplied as tiled zones with separate circuits, which is usually better engineering anyway: separate zones can be controlled separately, and a large single circuit has to carry the whole current at one lead exit.

Which heaters work at 120 °c to 150 °c?

Process and platen heating, adhesive curing, epoxy-encapsulated plates at their limit. Silicone and polyimide are comfortable here; the encapsulant, not the element, is usually what constrains the design.

Is the temperature rating the surface temperature or the element temperature?

The element temperature, which is the hottest point in the assembly and the one nothing on the outside is measuring. The surface being heated sits below it by whatever the thermal path costs — a few degrees through a good bond, tens of degrees across a void or a dry clamped joint.

What is the maximum temperature of type k and type j thermocouples?

400 °C continuous, measured at the element. The limit belongs to the insulation system and not to the element alloy, so it is not a figure that can be extended by derating the power.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.