Skip to content
Epoxy Heating Plates · UL 499 / IEC 60335 / RoHS

Battery Module Epoxy Heating Plates for 120-150 °C

Which insulation systems hold 120 °C to 150 °C continuously, what this construction is rated to, and the control and cut-out that hold the surface there.

Battery Module Epoxy Heating Plates are rated 150 °C continuous, a limit set by the thermally conductive filled epoxy, which covers 120 °C to 150 °C. Process and platen heating, adhesive curing, epoxy-encapsulated plates at their limit. Silicone and polyimide are comfortable here; the encapsulant, not the element, is usually what constrains the design.

Working band
120 °C to 150 °C
Continuous limit, this construction
150 °C
Set by
Thermally conductive filled epoxy
Watt density
0.2 W/cm² free air, 1 W/cm² bonded
Total thickness
4 mm to 10 mm
Maximum outline, one piece
300 x 500 mm

The band is the temperature the heated surface has to hold, not the temperature the element reaches. The element always runs hotter, by an amount the watt density and the thermal path decide, so the cut-out is set against the element and not against the load.

Battery Module Epoxy Heating Plates — the construction this guide is about

Duty temperature decides the construction before anything else does. At 120 °c to 150 °c, battery module epoxy heating plates is a candidate; the sections below set out what it will hold, what has to be true for it to hold it, and what fails first when it does not.

What the 120 °C to 150 °C Band Requires

Process and platen heating, adhesive curing, epoxy-encapsulated plates at their limit. Silicone and polyimide are comfortable here; the encapsulant, not the element, is usually what constrains the design.

Band120 °C to 150 °C
This construction, continuous150 °C
Limited bythermally conductive filled epoxy

This band reaches the ceiling of the construction. At 150 °C there is no headroom left, so the control has to hold the set point rather than approach it from above, and the limit device has to be set where it can act before the insulation does. A duty that spends its time at the top of the band is a duty that should be quoted against the next construction up.

Why the Boundary Is Where It Is

150 °C is the ceiling of filled epoxy, and on an encapsulated plate the encapsulant fails before either the element or the plate is troubled. It is also roughly where acrylic pressure-sensitive adhesives give up, which matters on any heater that is held on by its own adhesive rather than clamped.

Silicone and polyimide are comfortable through this band with 50 °C of margin in hand; the constraint is usually the bonding system, not the heater.

What a Battery Module Epoxy Heating Plates Is

Heating plates that sit under or between battery modules, potted flat so the whole cell face is in contact and no cell sees a hot spot.

A resistance wire or foil element vacuum potted in thermally conductive filled epoxy against an aluminium or steel plate. Rigid, flat, sealed, and thermally bonded to its own plate so the heat leaves the element through metal rather than through air. Against a module face the plate does the work a flexible heater cannot: it stays flat under clamping load and spreads a low watt density evenly across cells that must not see a gradient.

The plate is the thermal path: the element is potted against it, so the metal spreads the heat before the load ever sees it. That is what buys uniformity, and it is also what makes the assembly slow — a bolted plate takes minutes to reach steady state where a film takes seconds.

Elementresistance wire or foil, vacuum potted
Insulation systemthermally conductive filled epoxy
Total thickness4 mm to 10 mm
Maximum size, one piece300 x 500 mm
Continuous working temperature150 °C

The continuous limit of 150 °C is set by thermally conductive filled epoxy. The element alloy would run far hotter; it is never the element that decides.

Which Temperature Is Being Held

Three temperatures matter and they are not the same number: the element temperature, the temperature of the surface being heated, and the ambient. A heater rated for a continuous working temperature is rated at the element — the hottest point in the assembly, and the one nothing on the outside is measuring.

The gap between element and surface is the thermal path. Bonded to metal it may be a few degrees; across an air gap, a void in the adhesive or a dry clamped joint it can be tens of degrees, and every one of them appears at the element rather than at the load.

Which is why sensor position is a drawing item. A sensor laminated into the heater protects the heater; a sensor on the load controls the load. Assemblies that have to do both carry two: a control sensor where the process is, and a limit device against the element.

Uniformity across the heated face is u00b12 u00b0C across the plate face, achieved by varying the element pitch across the outline rather than by adding wattage — the cold corner of a heated plate is a layout problem, and more power makes the hot part hotter.

Watt Density: the Two Figures

This construction is rated at 0.2 W/cm² in free air and 1 W/cm² bonded over its whole area to metal. The second figure is 5 times the first, and the difference is not a safety margin — it is the heat sink. On a 100 x 150 mm outline, which is 150 cm², that is about 3 W hanging in air against about 15 W bonded down.

Specify at the figure that matches how the heater will actually run. A heater ordered at the bonded density and then switched on before it is attached — on the bench, during a test, after it has lifted off in service — reaches its insulation limit in minutes, because there is nowhere for the heat to go but through the insulation.

Control and Protection

This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.

The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.

The limit that matters is the epoxy's, at 150 °C, and it is reached at the element long before the plate face reads anything alarming. Put the limit device in the potting against the element, not on the outside of the plate.

Sensors can be built into the part: NTC thermistor, PT100 or PT1000 RTD, or a K-type thermocouple, fitted under the same insulation and tested with the heater as one assembly. A sensor laminated into the heater reads the heater; a sensor on the load reads the load. Both are legitimate, and the drawing has to say which is wanted.

Where This Construction Is the Wrong Answer

  • Do not plan on running above 150 °C. That ceiling belongs to the insulation system, not to the element alloy, and it is not a figure that derating extends — past it the insulation degrades and the dielectric strength goes with it.
  • Do not put an epoxy plate where a flexible heater is really wanted. It will not conform, and clamping it against a surface that is not flat loads the potting rather than the joint.

Other Constructions That Hold 120 °C to 150 °C

Constructions in this catalogue that will hold 120 °c to 150 °c continuously:

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • An outline drawing, or a sketch with dimensions: overall size, holes, cut-outs, radii and the lead exit position.
  • The supply voltage, and whether it is AC or DC. The element is wound for one voltage; it is not a switchable range.
  • The power required, or — better — the temperature to be reached and the mass or flow it has to be reached in. Given the second, the wattage can be calculated instead of guessed.
  • What the heater is attached to, and how. This is what decides which watt density figure applies, and it is the question a quotation cannot proceed without.
  • The ambient, and the lowest temperature the assembly must start from. A heater sized for a 20 °C start is undersized for a -30 °C one.
  • Duty cycle: continuous, intermittent, or a warm-up to a deadline. Time to temperature is a specification, not a by-product.
  • Sensor and protection: which sensor, where it goes, and which limit device is fitted in series with the element.
  • The certification the end product is built to, named on the enquiry rather than after approval.
  • Quantity and target price, because the construction that is right for fifty pieces is often not the one that is right for fifty thousand.
  • The plate material, thickness and mounting hole pattern, and what the plate is bolted to.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

Battery Module Epoxy Heating Plates — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
ConstructionResistance wire or foil element potted in thermally conductive filled epoxy on a metal plateCured under vacuum so there are no voids in the heat path
Plate materialAluminium 6061 or 3003, 2 mm to 6 mmAluminium for spreading, stainless where the chemistry demands it
Total thickness4 mm to 10 mmPlate plus encapsulation
Maximum size, one piece300 x 500 mmLarger plates are built as multiple circuits on one plate
Dimensional toleranceu00b10.5 mm on the plate, u00b11 mm on the encapsulation
Supply voltage12 V, 24 V, 48 VWound to order
Resistance toleranceu00b110%At 20 u00b0C
Watt density0.2 W/cmu00b2 typical, 1.0 W/cmu00b2 maximumAgainst a load in contact; free-standing operation runs far lower
Continuous working temperature-40 u00b0C to +150 u00b0CSet by the epoxy, not by the element
Dielectric strength2500 V AC, 1 minuteElement to plate
Insulation resistancegreater than 100 Mu03a9 at 500 V DCAlso after 48 hours humidity conditioning
Ingress protectionIP65 as standard, IP67 with a moulded lead entryThe encapsulation is the seal
MountingTapped holes, clearance holes, studs or bondedMachined into the plate before potting
Sensor optionsNTC, PT100 or thermostat potted into the same plateReads the plate, which is what the load actually sees
Certifications availableUL 499, IEC/EN 60335, RoHS, REACH, CE, IATF 16949Construction level
Uniformityu00b12 u00b0C across the plate faceA cell that is 5 u00b0C warmer than its neighbours ages faster than them, permanently
VibrationTested to IEC 60068-2-6, 10-500 HzThe encapsulation is what makes a potted plate survive a vehicle floor

Capability figures are for resistance elements encapsulated in thermally conductive filled epoxy on a metal plate. The +150 °C continuous limit is a property of the encapsulant, and it is the lowest limit of any construction in this catalog — the element and the plate would both tolerate far more.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.

Build the Drawing

The panel above checks whether a size and a wattage can be built. This is the drawing itself: set the outline, route the heating track, place the lead wires, terminals, connector and temperature sensor, working in custom outline, and turn the model to look at it. When it is right, export the 2D drawing as a PDF or a DXF and send it with your enquiry — a drawing is what a quotation for battery module epoxy heating plates is actually written from.

HEATING FILM DRAWING
Custom / Special-Shaped Heating Film

Draw the outline, route the heating track, place the lead exits, terminals and sensor, dimension it, then export a PDF or a DXF and send it with your enquiry. Nothing here is a stock part and nothing you draw commits you to anything.

CMD

Want to compare constructions before you draw? Open the full builder, where every film family is selectable in one place.

Our facility

Where these heaters are actually made

Circuit layout, element preparation, lamination and vulcanising, die cutting and lead attachment all happen under one roof, so a watt density limit and a temperature ceiling are set by processes we control and can evidence, not by whichever supplier had stock.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (UL 499 / IEC 60335 / RoHS)

ParameterSpecificationLimit / note
ConstructionResistance wire or foil element potted in thermally conductive filled epoxy on a metal plateCured under vacuum so there are no voids in the heat path
Plate materialAluminium 6061 or 3003, 2 mm to 6 mmAluminium for spreading, stainless where the chemistry demands it
Total thickness4 mm to 10 mmPlate plus encapsulation
Maximum size, one piece300 x 500 mmLarger plates are built as multiple circuits on one plate
Dimensional toleranceu00b10.5 mm on the plate, u00b11 mm on the encapsulation
Supply voltage12 V, 24 V, 48 VWound to order
Resistance toleranceu00b110%At 20 u00b0C
Watt density0.2 W/cmu00b2 typical, 1.0 W/cmu00b2 maximumAgainst a load in contact; free-standing operation runs far lower
Continuous working temperature-40 u00b0C to +150 u00b0CSet by the epoxy, not by the element
Dielectric strength2500 V AC, 1 minuteElement to plate
Insulation resistancegreater than 100 Mu03a9 at 500 V DCAlso after 48 hours humidity conditioning
Ingress protectionIP65 as standard, IP67 with a moulded lead entryThe encapsulation is the seal
MountingTapped holes, clearance holes, studs or bondedMachined into the plate before potting
Sensor optionsNTC, PT100 or thermostat potted into the same plateReads the plate, which is what the load actually sees
Certifications availableUL 499, IEC/EN 60335, RoHS, REACH, CE, IATF 16949Construction level
Uniformityu00b12 u00b0C across the plate faceA cell that is 5 u00b0C warmer than its neighbours ages faster than them, permanently
VibrationTested to IEC 60068-2-6, 10-500 HzThe encapsulation is what makes a potted plate survive a vehicle floor

Video: Battery Module Epoxy Heating Plates for 120-150 °C

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

Is the temperature rating the surface temperature or the element temperature?

The element temperature, which is the hottest point in the assembly and the one nothing on the outside is measuring. The surface being heated sits below it by whatever the thermal path costs — a few degrees through a good bond, tens of degrees across a void or a dry clamped joint.

What watt density can battery module epoxy heating plates run at?

0.2 W/cm² with nothing conducting the heat away, and 1 W/cm² bonded over its whole area to metal. The two figures describe two different installations, not a range to choose from: a heater specified at 1 W/cm² and then run in free air reaches its insulation limit within minutes.

What is the maximum temperature of battery module epoxy heating plates?

150 °C continuous, measured at the element. The limit belongs to thermally conductive filled epoxy and not to the element alloy, so it is not a figure that can be extended by derating the power.

Does this heater need a thermostat?

Yes. It has no mechanism for limiting its own temperature — with the load removed or the control loop failed it keeps producing the same power — so the design needs a controller with a sensor to hold the set point and, separately, a bimetal thermostat or a one-shot thermal cutoff in series with the element as protection.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.