Skip to content
PTC Heaters · IEC 60335 / UL 499 / RoHS

PTC Aluminium Plate Heaters for 120-150 °C

Which insulation systems hold 120 °C to 150 °C continuously, what this construction is rated to, and how the Curie point is chosen to sit in that band.

PTC Aluminium Plate Heaters are rated 200 °C continuous, a limit set by the aluminium carrier with insulating film, which covers 120 °C to 150 °C. Process and platen heating, adhesive curing, epoxy-encapsulated plates at their limit. Silicone and polyimide are comfortable here; the encapsulant, not the element, is usually what constrains the design.

Working band
120 °C to 150 °C
Continuous limit, this construction
200 °C
Set by
Aluminium carrier with insulating film
Watt density
0.8 W/cm² free air, 4 W/cm² bonded
Total thickness
Element 1.5 mm to 3 mm; assembly to your drawing
Maximum outline, one piece
40 x 60 mm to 200 x 300 mm

The band is the surface temperature the heater has to hold. A PTC element settles near its Curie point under whatever cooling it has, so the Curie point is chosen for the band and the delivered power follows from the thermal path rather than from a nameplate.

PTC Aluminium Plate Heaters — the construction this guide is about

Duty temperature decides the construction before anything else does. At 120 °c to 150 °c, ptc aluminium plate heaters is a candidate; the sections below set out what it will hold, what has to be true for it to hold it, and what fails first when it does not.

What the 120 °C to 150 °C Band Requires

Process and platen heating, adhesive curing, epoxy-encapsulated plates at their limit. Silicone and polyimide are comfortable here; the encapsulant, not the element, is usually what constrains the design.

Band120 °C to 150 °C
This construction, continuous200 °C
Limited byaluminium carrier with insulating film

The band sits comfortably inside the 200 °C ceiling, which is where a heater should be specified: the margin between the working temperature and the insulation limit is what absorbs a poor thermal path, a warm ambient and a control overshoot without shortening the life of the part.

Why the Boundary Is Where It Is

150 °C is the ceiling of filled epoxy, and on an encapsulated plate the encapsulant fails before either the element or the plate is troubled. It is also roughly where acrylic pressure-sensitive adhesives give up, which matters on any heater that is held on by its own adhesive rather than clamped.

Silicone and polyimide are comfortable through this band with 50 °C of margin in hand; the constraint is usually the bonding system, not the heater.

What a PTC Aluminium Plate Heaters Is

PTC elements bonded to a flat aluminium plate for conduction heating of a surface that must not be allowed to overshoot.

Barium titanate ceramic whose resistance rises steeply above its Curie point, so the power it draws falls as the surface approaches that temperature. The element cannot exceed the Curie point it was made to, whatever the supply or the control does. Bonded to an aluminium plate the ceramic is spread out into a uniform surface, and the plate is also what carries the heat away — an element clamped to nothing regulates itself down to almost no power at all.

The heat leaves through a clamped joint, and a clamped joint is only as good as the pressure and the flatness behind it. A thermal interface material or a thin film of thermal grease fills the gaps that machining leaves; without one, contact happens at the high spots and the element runs hotter than the plate it is bolted to.

Elementbarium titanate PTC ceramic
Insulation systemaluminium carrier with insulating film
Total thicknessElement 1.5 mm to 3 mm; assembly to your drawing
Maximum size, one piece40 x 60 mm to 200 x 300 mm
Continuous working temperature200 °C

The continuous limit of 200 °C is set by aluminium carrier with insulating film. The element alloy would run far hotter; it is never the element that decides.

Which Temperature Is Being Held

Three temperatures matter and they are not the same number: the element temperature, the temperature of the surface being heated, and the ambient. A heater rated for a continuous working temperature is rated at the element — the hottest point in the assembly, and the one nothing on the outside is measuring.

The gap between element and surface is the thermal path. Bonded to metal it may be a few degrees; across an air gap, a void in the adhesive or a dry clamped joint it can be tens of degrees, and every one of them appears at the element rather than at the load.

Watt Density: the Two Figures

This construction is rated at 0.8 W/cm² in free air and 4 W/cm² bonded over its whole area to metal. The second figure is 5 times the first, and the difference is not a safety margin — it is the heat sink. On a 100 x 150 mm outline, which is 150 cm², that is about 12 W hanging in air against about 6 W bonded down.

Specify at the figure that matches how the heater will actually run. A heater ordered at the bonded density and then switched on before it is attached — on the bench, during a test, after it has lifted off in service — reaches its insulation limit in minutes, because there is nowhere for the heat to go but through the insulation.

A PTC assembly behaves differently at the limit. Deprived of its heat sink it does not run away; it reduces its own power. The consequence of a poor thermal path here is a heater that delivers well under its nameplate power, not one that destroys itself.

Control and Protection

This is the one construction here that limits its own temperature. Above the Curie point the ceramic's resistance rises steeply, the current falls, and the element settles rather than climbing — so a PTC heater cannot thermally run away even with the control shorted out.

That is a safety property, not an accuracy one. Self-regulation holds a surface somewhere near the Curie point under whatever cooling it happens to have; it does not hold a set point, and the temperature it settles at moves with airflow, with supply voltage and with the load. Where a number has to be held, a sensor and a controller are still required.

Two things still have to be designed for: the inrush, which is several times the running current while the ceramic is cold and which the supply and any switching device must tolerate, and the electrical fault case, which self-regulation does nothing about — a fuse or a current-limited supply is still the protection against a short.

Where This Construction Is the Wrong Answer

  • Do not plan on running above 200 °C. That ceiling belongs to the insulation system, not to the element alloy, and it is not a figure that derating extends — past it the insulation degrades and the dielectric strength goes with it.
  • Do not use self-regulation as a substitute for temperature control where a set point matters, and do not present it as a substitute for a fuse. It bounds the temperature; it does not hold a value and it does nothing about a short circuit.

Other Constructions That Hold 120 °C to 150 °C

Constructions in this catalogue that will hold 120 °c to 150 °c continuously:

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • An outline drawing, or a sketch with dimensions: overall size, holes, cut-outs, radii and the lead exit position.
  • The supply voltage, and whether it is AC or DC. The element is wound for one voltage; it is not a switchable range.
  • The power required, or — better — the temperature to be reached and the mass or flow it has to be reached in. Given the second, the wattage can be calculated instead of guessed.
  • What the heater is attached to, and how. This is what decides which watt density figure applies, and it is the question a quotation cannot proceed without.
  • The ambient, and the lowest temperature the assembly must start from. A heater sized for a 20 °C start is undersized for a -30 °C one.
  • Duty cycle: continuous, intermittent, or a warm-up to a deadline. Time to temperature is a specification, not a by-product.
  • Sensor and protection: which sensor, where it goes, and which limit device is fitted in series with the element.
  • The certification the end product is built to, named on the enquiry rather than after approval.
  • Quantity and target price, because the construction that is right for fifty pieces is often not the one that is right for fifty thousand.
  • The Curie point wanted, and the airflow or thermal path the assembly will have — both decide the power the element will actually deliver.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

PTC Aluminium Plate Heaters — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
ConstructionBarium titanate PTC ceramic, electroded on both faces, in an aluminium carrierAssembly built around the element to suit the load
Curie temperature+60 u00b0C to +200 u00b0C, selectedSelected at order u2014 it is the surface temperature ceiling and cannot be adjusted afterwards
Self-regulationPower falls to a fraction of rated as the surface reaches the Curie pointNo thermostat is required to prevent runaway; one may still be wanted for control
Element size40 x 60 mm to 200 x 300 mmStandard element footprints; assemblies to your drawing
Supply voltage12 V, 24 V, 48 V, 110 V, 220 VThe same element works over a voltage band with different output
Power output0.8 W/cmu00b2 typical in still air, 4.0 W/cmu00b2 with forced airOutput is set by the airflow, not by a setting u2014 this is what self-regulating means
Inrush current3 to 8 times running current for 1 to 3 secondsThe supply and any relay or MOSFET must tolerate it
Dielectric strength1800 V AC, 1 minute, element to caseOn the assembled unit with its insulation in place
Insulation resistancegreater than 100 Mu03a9 at 500 V DC
TerminationsFaston 2.8/4.8 mm, crimp, or flying leadsChosen for the assembly temperature
LifeOver 10,000 hours at rated conditionsAgeing shows as a slow rise in cold resistance, not as sudden failure
Certifications availableUL 499, IEC/EN 60335, RoHS, REACH, CE, IATF 16949Construction level
Surface temperatureSettles near the Curie point regardless of loadWhich is why this is chosen for a surface a person or a plastic part can touch

Capability figures are for barium titanate PTC ceramic elements and the aluminium assemblies built around them. The defining property — that power falls steeply as the element approaches its Curie point, so surface temperature cannot run away — is inherent to the ceramic, not a feature of the control.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.

Build the Drawing

The panel above checks whether a size and a wattage can be built. This is the drawing itself: set the outline, route the heating track, place the lead wires, terminals, connector and temperature sensor, working in PET / PTC film, and turn the model to look at it. When it is right, export the 2D drawing as a PDF or a DXF and send it with your enquiry — a drawing is what a quotation for ptc aluminium plate heaters is actually written from.

HEATING FILM DRAWING
PET / PTC Film Heater

Draw the outline, route the heating track, place the lead exits, terminals and sensor, dimension it, then export a PDF or a DXF and send it with your enquiry. Nothing here is a stock part and nothing you draw commits you to anything.

CMD

Want to compare constructions before you draw? Open the full builder, where every film family is selectable in one place.

Our facility

Held in production, not just on paper

The limits above are the ones our own lamination press, die and test lines actually hold, and every unit is tested rather than a sample. A figure is only worth quoting if it survives the process that produces it.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (IEC 60335 / UL 499 / RoHS)

ParameterSpecificationLimit / note
ConstructionBarium titanate PTC ceramic, electroded on both faces, in an aluminium carrierAssembly built around the element to suit the load
Curie temperature+60 u00b0C to +200 u00b0C, selectedSelected at order u2014 it is the surface temperature ceiling and cannot be adjusted afterwards
Self-regulationPower falls to a fraction of rated as the surface reaches the Curie pointNo thermostat is required to prevent runaway; one may still be wanted for control
Element size40 x 60 mm to 200 x 300 mmStandard element footprints; assemblies to your drawing
Supply voltage12 V, 24 V, 48 V, 110 V, 220 VThe same element works over a voltage band with different output
Power output0.8 W/cmu00b2 typical in still air, 4.0 W/cmu00b2 with forced airOutput is set by the airflow, not by a setting u2014 this is what self-regulating means
Inrush current3 to 8 times running current for 1 to 3 secondsThe supply and any relay or MOSFET must tolerate it
Dielectric strength1800 V AC, 1 minute, element to caseOn the assembled unit with its insulation in place
Insulation resistancegreater than 100 Mu03a9 at 500 V DC
TerminationsFaston 2.8/4.8 mm, crimp, or flying leadsChosen for the assembly temperature
LifeOver 10,000 hours at rated conditionsAgeing shows as a slow rise in cold resistance, not as sudden failure
Certifications availableUL 499, IEC/EN 60335, RoHS, REACH, CE, IATF 16949Construction level
Surface temperatureSettles near the Curie point regardless of loadWhich is why this is chosen for a surface a person or a plastic part can touch

Video: PTC Aluminium Plate Heaters for 120-150 °C

PTC120-G51F12B | 12V 120W fan PTC heating Element air heater incubator ceramic

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

How large can one piece be?

40 x 60 mm to 200 x 300 mm in a single piece. Larger areas are supplied as tiled zones with separate circuits, which is usually better engineering anyway: separate zones can be controlled separately, and a large single circuit has to carry the whole current at one lead exit.

Which heaters work at 120 °c to 150 °c?

Process and platen heating, adhesive curing, epoxy-encapsulated plates at their limit. Silicone and polyimide are comfortable here; the encapsulant, not the element, is usually what constrains the design.

Is the temperature rating the surface temperature or the element temperature?

The element temperature, which is the hottest point in the assembly and the one nothing on the outside is measuring. The surface being heated sits below it by whatever the thermal path costs — a few degrees through a good bond, tens of degrees across a void or a dry clamped joint.

What watt density can ptc aluminium plate heaters run at?

0.8 W/cm² with nothing conducting the heat away, and 4 W/cm² bonded over its whole area to metal. The two figures describe two different installations, not a range to choose from: a heater specified at 4 W/cm² and then run in free air reaches its insulation limit within minutes.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.