Skip to content
PTC Heaters · IEC 60335 / UL 499 / RoHS

Finned PTC Air Heaters for 120-150 °C

Which insulation systems hold 120 °C to 150 °C continuously, what this construction is rated to, and how the Curie point is chosen to sit in that band.

Finned PTC Air Heaters are rated 250 °C continuous, a limit set by the aluminium carrier with insulating film, which covers 120 °C to 150 °C. Process and platen heating, adhesive curing, epoxy-encapsulated plates at their limit. Silicone and polyimide are comfortable here; the encapsulant, not the element, is usually what constrains the design.

Working band
120 °C to 150 °C
Continuous limit, this construction
250 °C
Set by
Aluminium carrier with insulating film
Watt density
1 W/cm² free air, 6 W/cm² bonded
Total thickness
Element 1.5 mm to 3 mm; assembly to your drawing
Maximum outline, one piece
50 x 50 mm to 250 x 150 mm frame

The band is the surface temperature the heater has to hold. A PTC element settles near its Curie point under whatever cooling it has, so the Curie point is chosen for the band and the delivered power follows from the thermal path rather than from a nameplate.

Finned PTC Air Heaters — the construction this guide is about

The 120 °c to 150 °c band is a material boundary, not a convention. Process and platen heating, adhesive curing, epoxy-encapsulated plates at their limit. Silicone and polyimide are comfortable here; the encapsulant, not the element, is usually what constrains the design. This page covers what that means for finned ptc air heaters, which is rated to 250 °C continuous.

What the 120 °C to 150 °C Band Requires

Process and platen heating, adhesive curing, epoxy-encapsulated plates at their limit. Silicone and polyimide are comfortable here; the encapsulant, not the element, is usually what constrains the design.

Band120 °C to 150 °C
This construction, continuous250 °C
Limited byaluminium carrier with insulating film

The band sits comfortably inside the 250 °C ceiling, which is where a heater should be specified: the margin between the working temperature and the insulation limit is what absorbs a poor thermal path, a warm ambient and a control overshoot without shortening the life of the part.

Why the Boundary Is Where It Is

150 °C is the ceiling of filled epoxy, and on an encapsulated plate the encapsulant fails before either the element or the plate is troubled. It is also roughly where acrylic pressure-sensitive adhesives give up, which matters on any heater that is held on by its own adhesive rather than clamped.

Silicone and polyimide are comfortable through this band with 50 °C of margin in hand; the constraint is usually the bonding system, not the heater.

What a Finned PTC Air Heaters Is

PTC elements bonded into an aluminium fin stack, for warming air in cabinets, dryers, vehicle cabins and enclosures.

Barium titanate ceramic whose resistance rises steeply above its Curie point, so the power it draws falls as the surface approaches that temperature. The element cannot exceed the Curie point it was made to, whatever the supply or the control does. The elements are clamped into an aluminium fin stack: with air moving through the fins the assembly runs cool and draws its rated power, and with the airflow blocked it simply throttles itself back instead of glowing.

The heat leaves through a clamped joint, and a clamped joint is only as good as the pressure and the flatness behind it. A thermal interface material or a thin film of thermal grease fills the gaps that machining leaves; without one, contact happens at the high spots and the element runs hotter than the plate it is bolted to.

Elementbarium titanate PTC ceramic
Insulation systemaluminium carrier with insulating film
Total thicknessElement 1.5 mm to 3 mm; assembly to your drawing
Maximum size, one piece50 x 50 mm to 250 x 150 mm frame
Continuous working temperature250 °C

The continuous limit of 250 °C is set by aluminium carrier with insulating film. The element alloy would run far hotter; it is never the element that decides.

Which Temperature Is Being Held

Three temperatures matter and they are not the same number: the element temperature, the temperature of the surface being heated, and the ambient. A heater rated for a continuous working temperature is rated at the element — the hottest point in the assembly, and the one nothing on the outside is measuring.

The gap between element and surface is the thermal path. Bonded to metal it may be a few degrees; across an air gap, a void in the adhesive or a dry clamped joint it can be tens of degrees, and every one of them appears at the element rather than at the load.

Attachment and Thermal Contact

The part is clamped, not bonded. What matters at the joint is flatness, contact pressure and a thermal interface material to fill what machining leaves behind — a dry joint between two nominally flat surfaces touches on perhaps a few percent of its area.

A PTC element clamped without a proper thermal path does not overheat — it throttles itself back and delivers a fraction of the power the assembly was specified for. The symptom of a bad joint here is a heater that seems underpowered rather than one that burns out.

The joint between the heated surface and the load carries every watt the element makes. Fill it: an interface pad, a thin film of thermal grease or a bonded assembly. Two dry surfaces bolted together are a thermal resistance, and that resistance appears as element temperature.

Control and Protection

This is the one construction here that limits its own temperature. Above the Curie point the ceramic's resistance rises steeply, the current falls, and the element settles rather than climbing — so a PTC heater cannot thermally run away even with the control shorted out.

That is a safety property, not an accuracy one. Self-regulation holds a surface somewhere near the Curie point under whatever cooling it happens to have; it does not hold a set point, and the temperature it settles at moves with airflow, with supply voltage and with the load. Where a number has to be held, a sensor and a controller are still required.

Two things still have to be designed for: the inrush, which is several times the running current while the ceramic is cold and which the supply and any switching device must tolerate, and the electrical fault case, which self-regulation does nothing about — a fuse or a current-limited supply is still the protection against a short.

How This Construction Fails

  • Run at the bonded watt density in free air. The insulation reaches its limit within minutes and the element burns through where the local density is highest. Specify at 6 W/cm² only where the heater is genuinely bonded to metal over its whole area; unbonded, the figure is 1 W/cm².
  • Inrush that the supply cannot deliver. A cold PTC draws several times its running current; an undersized supply or a small switching device sees that as a fault, and a relay contact welds.
  • A poor clamp. The element regulates itself down against a bad thermal joint, so the assembly quietly delivers a fraction of its rated power and the fault reads as a heater that is too small.

Other Constructions That Hold 120 °C to 150 °C

Constructions in this catalogue that will hold 120 °c to 150 °c continuously:

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • An outline drawing, or a sketch with dimensions: overall size, holes, cut-outs, radii and the lead exit position.
  • The supply voltage, and whether it is AC or DC. The element is wound for one voltage; it is not a switchable range.
  • The power required, or — better — the temperature to be reached and the mass or flow it has to be reached in. Given the second, the wattage can be calculated instead of guessed.
  • What the heater is attached to, and how. This is what decides which watt density figure applies, and it is the question a quotation cannot proceed without.
  • The ambient, and the lowest temperature the assembly must start from. A heater sized for a 20 °C start is undersized for a -30 °C one.
  • Duty cycle: continuous, intermittent, or a warm-up to a deadline. Time to temperature is a specification, not a by-product.
  • Sensor and protection: which sensor, where it goes, and which limit device is fitted in series with the element.
  • The certification the end product is built to, named on the enquiry rather than after approval.
  • Quantity and target price, because the construction that is right for fifty pieces is often not the one that is right for fifty thousand.
  • The Curie point wanted, and the airflow or thermal path the assembly will have — both decide the power the element will actually deliver.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

Finned PTC Air Heaters — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
ConstructionBarium titanate PTC ceramic, electroded on both faces, in an aluminium carrierAssembly built around the element to suit the load
Curie temperature+80 u00b0C to +250 u00b0C, selectedSelected at order u2014 it is the surface temperature ceiling and cannot be adjusted afterwards
Self-regulationPower falls to a fraction of rated as the surface reaches the Curie pointNo thermostat is required to prevent runaway; one may still be wanted for control
Element size50 x 50 mm to 250 x 150 mm frameStandard element footprints; assemblies to your drawing
Supply voltage12 V, 24 V, 110 V, 220 VThe same element works over a voltage band with different output
Power output1.0 W/cmu00b2 typical in still air, 6.0 W/cmu00b2 with forced airOutput is set by the airflow, not by a setting u2014 this is what self-regulating means
Inrush current3 to 8 times running current for 1 to 3 secondsThe supply and any relay or MOSFET must tolerate it
Dielectric strength1800 V AC, 1 minute, element to caseOn the assembled unit with its insulation in place
Insulation resistancegreater than 100 Mu03a9 at 500 V DC
TerminationsFaston 2.8/4.8 mm, crimp, or flying leadsChosen for the assembly temperature
LifeOver 10,000 hours at rated conditionsAgeing shows as a slow rise in cold resistance, not as sudden failure
Certifications availableUL 499, IEC/EN 60335, RoHS, REACH, CE, IATF 16949Construction level
Airflow0.5 to 5 m/s across the finsOutput rises with airflow automatically u2014 the element does the regulating
FanAxial or blower to your specification, or supplied withoutA PTC heater with a failed fan drops its own power instead of burning

Capability figures are for barium titanate PTC ceramic elements and the aluminium assemblies built around them. The defining property — that power falls steeply as the element approaches its Curie point, so surface temperature cannot run away — is inherent to the ceramic, not a feature of the control.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.

Build the Drawing

The panel above checks whether a size and a wattage can be built. This is the drawing itself: set the outline, route the heating track, place the lead wires, terminals, connector and temperature sensor, working in PET / PTC film, and turn the model to look at it. When it is right, export the 2D drawing as a PDF or a DXF and send it with your enquiry — a drawing is what a quotation for finned ptc air heaters is actually written from.

HEATING FILM DRAWING
PET / PTC Film Heater

Draw the outline, route the heating track, place the lead exits, terminals and sensor, dimension it, then export a PDF or a DXF and send it with your enquiry. Nothing here is a stock part and nothing you draw commits you to anything.

CMD

Want to compare constructions before you draw? Open the full builder, where every film family is selectable in one place.

Our facility

Held in production, not just on paper

The limits above are the ones our own lamination press, die and test lines actually hold, and every unit is tested rather than a sample. A figure is only worth quoting if it survives the process that produces it.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (IEC 60335 / UL 499 / RoHS)

ParameterSpecificationLimit / note
ConstructionBarium titanate PTC ceramic, electroded on both faces, in an aluminium carrierAssembly built around the element to suit the load
Curie temperature+80 u00b0C to +250 u00b0C, selectedSelected at order u2014 it is the surface temperature ceiling and cannot be adjusted afterwards
Self-regulationPower falls to a fraction of rated as the surface reaches the Curie pointNo thermostat is required to prevent runaway; one may still be wanted for control
Element size50 x 50 mm to 250 x 150 mm frameStandard element footprints; assemblies to your drawing
Supply voltage12 V, 24 V, 110 V, 220 VThe same element works over a voltage band with different output
Power output1.0 W/cmu00b2 typical in still air, 6.0 W/cmu00b2 with forced airOutput is set by the airflow, not by a setting u2014 this is what self-regulating means
Inrush current3 to 8 times running current for 1 to 3 secondsThe supply and any relay or MOSFET must tolerate it
Dielectric strength1800 V AC, 1 minute, element to caseOn the assembled unit with its insulation in place
Insulation resistancegreater than 100 Mu03a9 at 500 V DC
TerminationsFaston 2.8/4.8 mm, crimp, or flying leadsChosen for the assembly temperature
LifeOver 10,000 hours at rated conditionsAgeing shows as a slow rise in cold resistance, not as sudden failure
Certifications availableUL 499, IEC/EN 60335, RoHS, REACH, CE, IATF 16949Construction level
Airflow0.5 to 5 m/s across the finsOutput rises with airflow automatically u2014 the element does the regulating
FanAxial or blower to your specification, or supplied withoutA PTC heater with a failed fan drops its own power instead of burning

Video: Finned PTC Air Heaters for 120-150 °C

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

Which heaters work at 120 °c to 150 °c?

Process and platen heating, adhesive curing, epoxy-encapsulated plates at their limit. Silicone and polyimide are comfortable here; the encapsulant, not the element, is usually what constrains the design.

Is the temperature rating the surface temperature or the element temperature?

The element temperature, which is the hottest point in the assembly and the one nothing on the outside is measuring. The surface being heated sits below it by whatever the thermal path costs — a few degrees through a good bond, tens of degrees across a void or a dry clamped joint.

What watt density can finned ptc air heaters run at?

1 W/cm² with nothing conducting the heat away, and 6 W/cm² bonded over its whole area to metal. The two figures describe two different installations, not a range to choose from: a heater specified at 6 W/cm² and then run in free air reaches its insulation limit within minutes.

What is the maximum temperature of finned ptc air heaters?

250 °C continuous, measured at the element. The limit belongs to aluminium carrier with insulating film and not to the element alloy, so it is not a figure that can be extended by derating the power.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.