UL 94 V-0 KSD9700 Bimetal Thermostats

What UL 94 V-0 fixes, what it deliberately leaves to another document, and how it is evidenced on a heater built to a customer drawing.

A flammability rating for the plastic materials in the construction — self-extinguishing within 10 seconds with no flaming drips.

Standard
UL 94 V-0
What it does not cover
It is a material rating, not a product approval, and says nothing about the heater as an assembly.
Construction
KSD9700 Bimetal Thermostats
Built and tested to
IEC 60730 / IEC 60335 / RoHS
Continuous temperature limit
150 °C continuous

A construction is built and tested to a standard. A heater made to your outline has no certified part number of its own, so the approval sits with the end product and with the file you hold — what this factory supplies is the construction, the materials and the test records that let that file be assembled.

KSD9700 Bimetal Thermostats — the construction this guide is about

Certification page for ksd9700 bimetal thermostats under UL 94 V-0. A flammability rating for the plastic materials in the construction — self-extinguishing within 10 seconds with no flaming drips.

UL 94 V-0 — Scope

A flammability rating for the plastic materials in the construction — self-extinguishing within 10 seconds with no flaming drips.

What UL 94 V-0 Does Not Cover

It is a material rating, not a product approval, and says nothing about the heater as an assembly.

This is the division of labour to carry away from any heating standard: safety standards decide whether the part can hurt somebody, and say nothing about whether it holds a temperature, lasts five years or matches the last batch. Performance is a specification you write; safety is one the standard writes.

A flammability rating applies to a material specimen of a stated thickness, not to the assembly. A heater built entirely from V-0 materials is not a V-0 heater; it is a heater whose materials are rated, which is a useful thing to be able to state and a different claim.

How a Made-to-Drawing Heater Is Certified

A construction is built and tested to a standard. The insulation system, the creepage and clearance distances, the earthing, the lead anchorage, the temperature under fault and the marking are what the test covers — and all of those are properties of the construction rather than of the outline it is die-cut to.

So a custom outline does not have a certificate of its own, and no supplier can honestly hand you one. What is available is the construction file: the standard the build is tested to, the materials list with their own ratings, and the test reports. That is what an approvals engineer needs, and it is what the end product's own certification is built on.

The practical consequence: name UL 94 V-0 on the enquiry, not after approval. A construction chosen for cost and then asked to pass a standard afterwards usually has to be rebuilt, because the insulation thickness, the creepage distances and the lead anchorage are decided at design time and are not adjustable later.

What a KSD9700 Bimetal Thermostats Is

The small snap-action bimetal disc fitted inside most of the heaters in this catalog: it opens at a fixed temperature and closes again when the part has cooled.

A bimetal disc that opens a contact at a fixed temperature. It is not an accurate controller and is not meant to be one: it is the device that decides whether the heater around it survives a fault, and it is specified by its open temperature, its reset behaviour and the current it can break.

The heat leaves through whatever the component is clamped or bonded to; a sensing component adds no heat of its own and simply has to be in thermal contact with the thing it is reporting on.

Total thicknessComponent
Maximum size, one pieceComponent
Continuous working temperature150 °C

The continuous limit of 150 °C is set by the insulation system. The element alloy would run far hotter; it is never the element that decides.

Other Constructions Built to UL 94 V-0

Control and Protection

This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.

The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.

Leads and Terminations

Termination is specified on the drawing: lead length, gauge, insulation and the connector or tag at the end of it.

The lead exit is a thermal discontinuity as well as an electrical one. The joint between a fine element and a stranded lead is the hottest point of many heaters, so it is kept out of the highest watt density zone, strain relieved, and — where the exit sits in a hot area — insulated in PTFE rather than in silicone.

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • The temperature to be sensed or switched, and the tolerance the application actually needs.
  • Where the component sits — against the element, in the potting, on the load, or in the airflow.
  • The electrical duty: for a switching device, the voltage, the current and whether the load is AC or DC.
  • Lead length, insulation and termination, and whether the component is fitted by us into a heater assembly or supplied loose.
  • The standard the end product is certified to, so the component chosen is one that fits inside that approval.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

KSD9700 Bimetal Thermostats — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
TypeSnap-action bimetal disc, normally closed or normally openNormally closed is the protective configuration
Open temperature+40 u00b0C to +150 u00b0C in 5 u00b0C stepsFixed at manufacture u2014 it is not adjustable
Toleranceu00b15 u00b0C standard, u00b13 u00b0C selectedOn the open point, measured rising
Reset differential15 u00b0C to 25 u00b0C below the open pointWide differential is deliberate: it stops the contact chattering
Switching rating5 A at 250 V AC resistiveResistive only u2014 a heater is a resistive load, which is why this rating applies
Life10,000 cycles at rated loadFar more at a fraction of the rating
MountingVulcanised inside the heater, bonded to the plate, or boltedIt must read the part it is protecting, not the air near it
CertificationsUL, VDE, CQC on the componentComponent approval carries into the heater assembly file

Figures are the published tolerance and rating bands of the standard sensor and control components fitted to these heaters. Sensor tolerance classes follow IEC 60751 for RTDs and IEC 60584 for thermocouples; thermostat and thermal cutoff ratings are the component manufacturers' own.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.
Our facility

Where these heaters are actually made

Circuit layout, element preparation, lamination and vulcanising, die cutting and lead attachment all happen under one roof, so a watt density limit and a temperature ceiling are set by processes we control and can evidence, not by whichever supplier had stock.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (IEC 60730 / IEC 60335 / RoHS)

ParameterSpecificationLimit / note
TypeSnap-action bimetal disc, normally closed or normally openNormally closed is the protective configuration
Open temperature+40 u00b0C to +150 u00b0C in 5 u00b0C stepsFixed at manufacture u2014 it is not adjustable
Toleranceu00b15 u00b0C standard, u00b13 u00b0C selectedOn the open point, measured rising
Reset differential15 u00b0C to 25 u00b0C below the open pointWide differential is deliberate: it stops the contact chattering
Switching rating5 A at 250 V AC resistiveResistive only u2014 a heater is a resistive load, which is why this rating applies
Life10,000 cycles at rated loadFar more at a fraction of the rating
MountingVulcanised inside the heater, bonded to the plate, or boltedIt must read the part it is protecting, not the air near it
CertificationsUL, VDE, CQC on the componentComponent approval carries into the heater assembly file

Video: UL 94 V-0 KSD9700 Bimetal Thermostats

How To Replace An Old Thermostat With a New One

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

What does UL 94 V-0 not cover?

It is a material rating, not a product approval, and says nothing about the heater as an assembly. Safety standards decide whether a part can hurt somebody; they say nothing about whether it holds a temperature or lasts.

What is the maximum temperature of ksd9700 bimetal thermostats?

150 °C continuous, measured at the element. The limit belongs to the insulation system and not to the element alloy, so it is not a figure that can be extended by derating the power.

Does this heater need a thermostat?

Yes. It has no mechanism for limiting its own temperature — with the load removed or the control loop failed it keeps producing the same power — so the design needs a controller with a sensor to hold the set point and, separately, a bimetal thermostat or a one-shot thermal cutoff in series with the element as protection.

How large can one piece be?

Component in a single piece. Larger areas are supplied as tiled zones with separate circuits, which is usually better engineering anyway: separate zones can be controlled separately, and a large single circuit has to carry the whole current at one lead exit.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.