Aramid Paper (Nomex type) KSD9700 Bimetal Thermostats

What this insulation holds continuously, how thick the finished part is, the watt density it takes in free air and bonded, and where it stops being the right choice.

Aramid Paper (Nomex type) — To +180 °C continuous. A thin, tough, low-cost flexible insulation used where polyimide is unnecessary and silicone is too thick, mostly in transformer and appliance heating.

Insulation system
Aramid Paper (Nomex type)
Temperature range
To +180 °C continuous
Where it stops
Absorbs moisture, and its dielectric strength falls when it does.
Continuous temperature limit
150 °C continuous
Total thickness
Component
Maximum outline, one piece
Component

The temperature ceiling belongs to the insulation, not to the element: the resistance alloy would run far hotter, and it is the insulation around it that fails first. Figures are for the insulation system as built here; a part is quoted against the drawing, not against this table.

KSD9700 Bimetal Thermostats — the construction this guide is about

In ksd9700 bimetal thermostats, Aramid Paper (Nomex type) is the insulation system — and on a heater the insulation system is what sets the temperature limit, the flexibility and the dielectric strength. Its range is To +180 °C continuous. What that means in service, what attacks it, and what to use instead above its ceiling are below.

Aramid Paper (Nomex type) as an Insulation System

A thin, tough, low-cost flexible insulation used where polyimide is unnecessary and silicone is too thick, mostly in transformer and appliance heating.

Working rangeTo +180 °C continuous
Total thickness in this constructionComponent
Maximum size, one pieceComponent

A flexible insulation has to do three jobs at once: hold off the supply voltage, survive the element temperature, and bend without cracking. Thickness trades against all three — a thinner build responds faster and conforms better, and has less material between the element and whatever the heater is touching.

The Temperature Ceiling, and What Sets It

Working range: To +180 °C continuous. The ceiling belongs to the insulation. Nichrome will run red; aramid paper (nomex type) will not, and it is the material around the element that decides what the part is rated at.

This construction is rated 150 °C continuous. That is a continuous figure at the element, not an ambient and not a surface temperature measured somewhere convenient — and it is not a figure that derating extends downwards from something higher. Past the ceiling the insulation degrades, the dielectric strength falls with it, and the failure is electrical rather than thermal.

The boundaries across this catalogue are all material boundaries: PET stops at 120 °C, filled epoxy at 150 °C, silicone rubber and polyimide at 200 °C, and above that only fired and inorganic systems — thick film on stainless or alumina, and mica — are candidates at all.

What Attacks Aramid Paper (Nomex type)

Absorbs moisture, and its dielectric strength falls when it does.

What a KSD9700 Bimetal Thermostats Is

The small snap-action bimetal disc fitted inside most of the heaters in this catalog: it opens at a fixed temperature and closes again when the part has cooled.

A bimetal disc that opens a contact at a fixed temperature. It is not an accurate controller and is not meant to be one: it is the device that decides whether the heater around it survives a fault, and it is specified by its open temperature, its reset behaviour and the current it can break.

The heat leaves through whatever the component is clamped or bonded to; a sensing component adds no heat of its own and simply has to be in thermal contact with the thing it is reporting on.

Total thicknessComponent
Maximum size, one pieceComponent
Continuous working temperature150 °C

The continuous limit of 150 °C is set by the insulation system. The element alloy would run far hotter; it is never the element that decides.

Above Its Ceiling: What to Use Instead

Aramid paper is a 180 °C insulation used where polyimide is unnecessary and silicone is too thick. Above it, silicone rubber and polyimide both reach 200 °C; above 200 °C the polymers stop altogether and the construction changes to a fired or mica-insulated one. Its weakness is moisture — it absorbs it, and its dielectric strength falls when it does — so a damp installation is a reason to move to silicone even well below the temperature limit.

What the Insulation Changes About the Heater

The insulation decides the thickness (Component here), and the thickness decides the response: less material between the element and the load means less to heat before anything useful happens, and less thermal resistance in the way of the heat that follows. It also decides what the heater will wrap around — this construction wraps a cylinder but will not take a compound curve.

Control and Protection

This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.

The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.

T

h

How This Construction Fails

  • Loss of the control loop. An open-circuit sensor, a welded relay contact or a controller in manual leaves the element at full power with nothing watching it — the case the series thermal cutoff exists for, and the reason it must not be omitted to save a part.
  • Measuring the wrong thing. A sensor in the air near a heated plate reports the air, and the loop holds the air where the specification wanted the plate. Nothing in the instrument can detect this.

Leads and Terminations

Termination is specified on the drawing: lead length, gauge, insulation and the connector or tag at the end of it.

The lead exit is a thermal discontinuity as well as an electrical one. The joint between a fine element and a stranded lead is the hottest point of many heaters, so it is kept out of the highest watt density zone, strain relieved, and — where the exit sits in a hot area — insulated in PTFE rather than in silicone.

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • The temperature to be sensed or switched, and the tolerance the application actually needs.
  • Where the component sits — against the element, in the potting, on the load, or in the airflow.
  • The electrical duty: for a switching device, the voltage, the current and whether the load is AC or DC.
  • Lead length, insulation and termination, and whether the component is fitted by us into a heater assembly or supplied loose.
  • The standard the end product is certified to, so the component chosen is one that fits inside that approval.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

KSD9700 Bimetal Thermostats — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
TypeSnap-action bimetal disc, normally closed or normally openNormally closed is the protective configuration
Open temperature+40 u00b0C to +150 u00b0C in 5 u00b0C stepsFixed at manufacture u2014 it is not adjustable
Toleranceu00b15 u00b0C standard, u00b13 u00b0C selectedOn the open point, measured rising
Reset differential15 u00b0C to 25 u00b0C below the open pointWide differential is deliberate: it stops the contact chattering
Switching rating5 A at 250 V AC resistiveResistive only u2014 a heater is a resistive load, which is why this rating applies
Life10,000 cycles at rated loadFar more at a fraction of the rating
MountingVulcanised inside the heater, bonded to the plate, or boltedIt must read the part it is protecting, not the air near it
CertificationsUL, VDE, CQC on the componentComponent approval carries into the heater assembly file

Figures are the published tolerance and rating bands of the standard sensor and control components fitted to these heaters. Sensor tolerance classes follow IEC 60751 for RTDs and IEC 60584 for thermocouples; thermostat and thermal cutoff ratings are the component manufacturers' own.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.
Our facility

Held in production, not just on paper

The limits above are the ones our own lamination press, die and test lines actually hold, and every unit is tested rather than a sample. A figure is only worth quoting if it survives the process that produces it.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (IEC 60730 / IEC 60335 / RoHS)

ParameterSpecificationLimit / note
TypeSnap-action bimetal disc, normally closed or normally openNormally closed is the protective configuration
Open temperature+40 u00b0C to +150 u00b0C in 5 u00b0C stepsFixed at manufacture u2014 it is not adjustable
Toleranceu00b15 u00b0C standard, u00b13 u00b0C selectedOn the open point, measured rising
Reset differential15 u00b0C to 25 u00b0C below the open pointWide differential is deliberate: it stops the contact chattering
Switching rating5 A at 250 V AC resistiveResistive only u2014 a heater is a resistive load, which is why this rating applies
Life10,000 cycles at rated loadFar more at a fraction of the rating
MountingVulcanised inside the heater, bonded to the plate, or boltedIt must read the part it is protecting, not the air near it
CertificationsUL, VDE, CQC on the componentComponent approval carries into the heater assembly file

Video: Aramid Paper (Nomex type) KSD9700 Bimetal Thermostats

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

How large can one piece be?

Component in a single piece. Larger areas are supplied as tiled zones with separate circuits, which is usually better engineering anyway: separate zones can be controlled separately, and a large single circuit has to carry the whole current at one lead exit.

What temperature will Aramid Paper (Nomex type) stand?

To +180 °C continuous. That range is the insulation system's, and on a heater the insulation system is what sets the rating — the element will always outlast the material around it.

What are the weaknesses of Aramid Paper (Nomex type)?

Absorbs moisture, and its dielectric strength falls when it does.

What should I use instead of Aramid Paper (Nomex type) above its limit?

Aramid paper is a 180 °C insulation used where polyimide is unnecessary and silicone is too thick. Above it, silicone rubber and polyimide both reach 200 °C; above 200 °C the polymers stop altogether and the construction changes to a fired or mica-insulated one. Its weakness is moisture — it absorbs it, and its dielectric strength falls when it does — so a damp installation is a reason to move to silicone even well below the temperature limit.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.