IEC 60584 Digital and PID Temperature Controllers

What IEC 60584 fixes, what it deliberately leaves to another document, and how it is evidenced on a heater built to a customer drawing.

Thermocouples: the reference tables for types J, K, T and the rest, and the class 1 and class 2 tolerance bands.

Standard
IEC 60584
What it does not cover
It says nothing about the junction, the sheath or the cold-junction compensation, and those decide what the reading is actually worth in service.
Construction
Digital and PID Temperature Controllers
Built and tested to
IEC 60730 / IEC 60751 / IEC 60584
Continuous temperature limit
400 °C continuous

A construction is built and tested to a standard. A heater made to your outline has no certified part number of its own, so the approval sits with the end product and with the file you hold — what this factory supplies is the construction, the materials and the test records that let that file be assembled.

Digital and PID Temperature Controllers — the construction this guide is about

Certification page for digital and pid temperature controllers under IEC 60584. Thermocouples: the reference tables for types J, K, T and the rest, and the class 1 and class 2 tolerance bands.

IEC 60584 — Scope

Thermocouples: the reference tables for types J, K, T and the rest, and the class 1 and class 2 tolerance bands.

What IEC 60584 Does Not Cover

It says nothing about the junction, the sheath or the cold-junction compensation, and those decide what the reading is actually worth in service.

This is the division of labour to carry away from any heating standard: safety standards decide whether the part can hurt somebody, and say nothing about whether it holds a temperature, lasts five years or matches the last batch. Performance is a specification you write; safety is one the standard writes.

How a Made-to-Drawing Heater Is Certified

A construction is built and tested to a standard. The insulation system, the creepage and clearance distances, the earthing, the lead anchorage, the temperature under fault and the marking are what the test covers — and all of those are properties of the construction rather than of the outline it is die-cut to.

So a custom outline does not have a certificate of its own, and no supplier can honestly hand you one. What is available is the construction file: the standard the build is tested to, the materials list with their own ratings, and the test reports. That is what an approvals engineer needs, and it is what the end product's own certification is built on.

The practical consequence: name IEC 60584 on the enquiry, not after approval. A construction chosen for cost and then asked to pass a standard afterwards usually has to be rebuilt, because the insulation thickness, the creepage distances and the lead anchorage are decided at design time and are not adjustable later.

What a Digital and PID Temperature Controllers Is

Panel controllers to close the loop around the heater: on/off for simple holding, PID where the set point has to be reached without overshoot.

The instrument that closes the loop: it reads a sensor, compares it with a set point and switches the heater. It is what gives a heating system an accuracy figure — no heater has one on its own.

The heat leaves through whatever the component is clamped or bonded to; a sensing component adds no heat of its own and simply has to be in thermal contact with the thing it is reporting on.

Total thicknessComponent
Maximum size, one pieceComponent
Continuous working temperature400 °C

The continuous limit of 400 °C is set by the insulation system. The element alloy would run far hotter; it is never the element that decides.

Other Constructions Built to IEC 60584

Control and Protection

This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.

The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.

Attachment and Thermal Contact

A sensing component is fitted where it will read the temperature that matters: against the element for a limit device, against the load for a control device. The two positions give different numbers, and choosing the wrong one is the commonest reason a correctly built loop holds the wrong temperature.

A sensor reads its own junction, not the surface it is near. Bed it in thermal compound, clamp it, or pot it into the assembly: an air gap of a tenth of a millimetre between a thermistor and the plate it is supposed to be measuring is worth several degrees of error, and it is an error the controller cannot see.

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • The temperature to be sensed or switched, and the tolerance the application actually needs.
  • Where the component sits — against the element, in the potting, on the load, or in the airflow.
  • The electrical duty: for a switching device, the voltage, the current and whether the load is AC or DC.
  • Lead length, insulation and termination, and whether the component is fitted by us into a heater assembly or supplied loose.
  • The standard the end product is certified to, so the component chosen is one that fits inside that approval.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

Digital and PID Temperature Controllers — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
Control modesOn/off, PID with autotune, ramp/soak programmesOn/off is adequate for a lagged mass and hopeless for a thin plate
InputPT100, PT1000, NTC, thermocouple type K/J/T/EConfigurable at the front panel
Control accuracyu00b10.1% of span, u00b11 digitOf the instrument u2014 the loop is only as good as the sensor placement
OutputRelay 3 A, SSR drive 12 V DC, 4-20 mASSR drive for anything cycling faster than once a minute
AlarmsHigh, low, deviation, sensor breakSensor break must fail the heater off, and this should be verified rather than assumed
Supply100-240 V AC or 24 V DC
Panel size48x48, 72x72, 96x96 mm DIN
StandardIEC 60730 / IEC 61010Controller safety and functional standards

Figures are the published tolerance and rating bands of the standard sensor and control components fitted to these heaters. Sensor tolerance classes follow IEC 60751 for RTDs and IEC 60584 for thermocouples; thermostat and thermal cutoff ratings are the component manufacturers' own.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.
Our facility

The numbers come off our own machines

Every unit is measured for resistance, held at its dielectric test voltage for a minute, and measured again for insulation resistance. Sample units from each lot are run under power and imaged. That is why the values on this page are quotable rather than indicative.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (IEC 60730 / IEC 60751 / IEC 60584)

ParameterSpecificationLimit / note
Control modesOn/off, PID with autotune, ramp/soak programmesOn/off is adequate for a lagged mass and hopeless for a thin plate
InputPT100, PT1000, NTC, thermocouple type K/J/T/EConfigurable at the front panel
Control accuracyu00b10.1% of span, u00b11 digitOf the instrument u2014 the loop is only as good as the sensor placement
OutputRelay 3 A, SSR drive 12 V DC, 4-20 mASSR drive for anything cycling faster than once a minute
AlarmsHigh, low, deviation, sensor breakSensor break must fail the heater off, and this should be verified rather than assumed
Supply100-240 V AC or 24 V DC
Panel size48x48, 72x72, 96x96 mm DIN
StandardIEC 60730 / IEC 61010Controller safety and functional standards

Video: IEC 60584 Digital and PID Temperature Controllers

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

What is the maximum temperature of digital and pid temperature controllers?

400 °C continuous, measured at the element. The limit belongs to the insulation system and not to the element alloy, so it is not a figure that can be extended by derating the power.

Does this heater need a thermostat?

Yes. It has no mechanism for limiting its own temperature — with the load removed or the control loop failed it keeps producing the same power — so the design needs a controller with a sensor to hold the set point and, separately, a bimetal thermostat or a one-shot thermal cutoff in series with the element as protection.

How large can one piece be?

Component in a single piece. Larger areas are supplied as tiled zones with separate circuits, which is usually better engineering anyway: separate zones can be controlled separately, and a large single circuit has to carry the whole current at one lead exit.

Is this heater IEC 60584 approved?

The construction is built and tested to IEC 60584; the outline is yours, and a made-to-drawing outline does not carry a certificate of its own. What is available is the construction file — the standard the build is tested to, the material ratings and the test reports — which is what your own product approval is built on.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.