220-240 V AC KSD9700 Bimetal Thermostats

How this construction is wound for 220-240 V AC, with the temperature the insulation holds continuously and the control and cut-out the design has to carry.

220-240 V AC KSD9700 Bimetal Thermostats: continuous limit 150 °C continuous, total thickness Component, maximum single-piece outline Component. At 220 V every 100 W of element power draws about 0.5 A, so the lead gauge, the connector and the switching device are sized from the wattage before anything else is decided. At mains potential the construction needs mains-rated insulation, a protective earth or double insulation, and a hi-pot and leakage test on every piece.

Supply
220-240 V AC
Continuous temperature limit
150 °C continuous
Total thickness
Component
Maximum outline, one piece
Component

The element is wound to a resistance, so power follows the square of the supply: the same part on 240 V instead of 220 V makes about 19% more heat. The supply voltage is a drawing item, not a preference, and a heater wound for one voltage is not derated onto another.

KSD9700 Bimetal Thermostats — the construction this guide is about

A 220-240 V AC element is not a 24 V DC element with a different label on it — the resistance differs by the square of the ratio, and with it the conductor gauge and the whole circuit layout. This page sets out what 220-240 V AC does to the design of ksd9700 bimetal thermostats.

The Element at 220-240 V AC

Two equations do all the work: P = V²/R and I = P/V. At 220-240 V AC, 500 W is 96.8 Ω and 2.27 A.

Worked example500 W at 220-240 V AC
Element resistance, R = V²/P96.8 Ω
Current, I = P/V2.27 A

The span matters more than the example. At 220-240 V AC a 20 W element is 242 Ω and a 500 W element is 96.8 Ω — a factor of twenty-five in resistance, met by changing the conductor cross-section and the length of the path, both of which are constrained by the outline.

At mains voltage the difficulty is the opposite one. Current is modest — 2.27 A for the worked example — but the element is a long, fine conductor, and a low-wattage heater at 220-240 V AC is the hardest thing in this catalogue to build: 20 W means 242 Ω, which is a very long track to fit inside a small outline without the pitch becoming so tight that adjacent runs interact.

Where the arithmetic will not fit the outline, the usual answers are a lower supply voltage with a small power supply behind it, several circuits in series, or a different construction entirely. What does not work is thinning the conductor further: the track becomes the fuse.

Isolation, Earthing and Safety Class

220-240 V AC is a mains supply, and the construction is built to match: mains-rated insulation, a protective earth connection or a double-insulated build, and creepage and clearance distances held between the element and any accessible surface.

Leakage current is the figure that surprises people. A large heated area behaves as a distributed capacitance to earth, so a big mains heater has a measurable leakage even when it is perfectly sound, and an RCD protecting several of them can trip on the sum. Where several elements share a circuit, allow for the total.

What a KSD9700 Bimetal Thermostats Is

The small snap-action bimetal disc fitted inside most of the heaters in this catalog: it opens at a fixed temperature and closes again when the part has cooled.

A bimetal disc that opens a contact at a fixed temperature. It is not an accurate controller and is not meant to be one: it is the device that decides whether the heater around it survives a fault, and it is specified by its open temperature, its reset behaviour and the current it can break.

The heat leaves through whatever the component is clamped or bonded to; a sensing component adds no heat of its own and simply has to be in thermal contact with the thing it is reporting on.

Total thicknessComponent
Maximum size, one pieceComponent
Continuous working temperature150 °C

The continuous limit of 150 °C is set by the insulation system. The element alloy would run far hotter; it is never the element that decides.

Switching an AC Element

AC switching has a zero crossing to hide behind. A zero-cross solid state relay makes and breaks at the crossing, which all but removes the switching transient and the conducted emissions that go with it — worth having on any installation that also has to pass an EMC test.

Control by burst firing — whole cycles on, whole cycles off, over a period of a second or more — rather than by phase angle. Burst firing generates almost no harmonics; phase angle control chops the waveform and is the reason a heater ends up in the EMC report at all. A heater has enough thermal inertia that a one-second period is invisible at the surface.

Size the relay for the inrush, not the running current, and heatsink it: a triac or SSR drops around one volt per amp of load, and that is real power to be got rid of inside the panel.

Attachment and Thermal Contact

A sensing component is fitted where it will read the temperature that matters: against the element for a limit device, against the load for a control device. The two positions give different numbers, and choosing the wrong one is the commonest reason a correctly built loop holds the wrong temperature.

From the capability table: Vulcanised inside the heater, bonded to the plate, or bolted.

A sensor reads its own junction, not the surface it is near. Bed it in thermal compound, clamp it, or pot it into the assembly: an air gap of a tenth of a millimetre between a thermistor and the plate it is supposed to be measuring is worth several degrees of error, and it is an error the controller cannot see.

Leads and Terminations

Termination is specified on the drawing: lead length, gauge, insulation and the connector or tag at the end of it.

The lead exit is a thermal discontinuity as well as an electrical one. The joint between a fine element and a stranded lead is the hottest point of many heaters, so it is kept out of the highest watt density zone, strain relieved, and — where the exit sits in a hot area — insulated in PTFE rather than in silicone.

Control and Protection

This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.

The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.

Which Constructions Are Wound for 220-240 V AC

220-240 V AC is not unique to this construction. In this catalogue it is also wound into:

The supply voltage is wound in at manufacture. A heater built for one voltage cannot be run on another and rated down by arithmetic — at half the voltage it makes a quarter of the power, and at twice the voltage it makes four times the power and destroys itself.

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • The temperature to be sensed or switched, and the tolerance the application actually needs.
  • Where the component sits — against the element, in the potting, on the load, or in the airflow.
  • The electrical duty: for a switching device, the voltage, the current and whether the load is AC or DC.
  • Lead length, insulation and termination, and whether the component is fitted by us into a heater assembly or supplied loose.
  • The standard the end product is certified to, so the component chosen is one that fits inside that approval.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

KSD9700 Bimetal Thermostats — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
TypeSnap-action bimetal disc, normally closed or normally openNormally closed is the protective configuration
Open temperature+40 u00b0C to +150 u00b0C in 5 u00b0C stepsFixed at manufacture u2014 it is not adjustable
Toleranceu00b15 u00b0C standard, u00b13 u00b0C selectedOn the open point, measured rising
Reset differential15 u00b0C to 25 u00b0C below the open pointWide differential is deliberate: it stops the contact chattering
Switching rating5 A at 250 V AC resistiveResistive only u2014 a heater is a resistive load, which is why this rating applies
Life10,000 cycles at rated loadFar more at a fraction of the rating
MountingVulcanised inside the heater, bonded to the plate, or boltedIt must read the part it is protecting, not the air near it
CertificationsUL, VDE, CQC on the componentComponent approval carries into the heater assembly file

Figures are the published tolerance and rating bands of the standard sensor and control components fitted to these heaters. Sensor tolerance classes follow IEC 60751 for RTDs and IEC 60584 for thermocouples; thermostat and thermal cutoff ratings are the component manufacturers' own.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.
Our facility

Where these heaters are actually made

Circuit layout, element preparation, lamination and vulcanising, die cutting and lead attachment all happen under one roof, so a watt density limit and a temperature ceiling are set by processes we control and can evidence, not by whichever supplier had stock.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (IEC 60730 / IEC 60335 / RoHS)

ParameterSpecificationLimit / note
TypeSnap-action bimetal disc, normally closed or normally openNormally closed is the protective configuration
Open temperature+40 u00b0C to +150 u00b0C in 5 u00b0C stepsFixed at manufacture u2014 it is not adjustable
Toleranceu00b15 u00b0C standard, u00b13 u00b0C selectedOn the open point, measured rising
Reset differential15 u00b0C to 25 u00b0C below the open pointWide differential is deliberate: it stops the contact chattering
Switching rating5 A at 250 V AC resistiveResistive only u2014 a heater is a resistive load, which is why this rating applies
Life10,000 cycles at rated loadFar more at a fraction of the rating
MountingVulcanised inside the heater, bonded to the plate, or boltedIt must read the part it is protecting, not the air near it
CertificationsUL, VDE, CQC on the componentComponent approval carries into the heater assembly file

Video: 220-240 V AC KSD9700 Bimetal Thermostats

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

How much current does a heater draw at 220-240 V AC?

I = P/V. At 220-240 V AC a 100 W heater draws 0.45 A and its element is 484 Ω; a 500 W heater draws 2.27 A and is 96.8 Ω. The current is what sizes the lead wire, the connector and the switching device, and at low voltage it is the whole design problem.

Can a 220-240 V AC heater be run on another voltage?

No. The element is wound for one voltage at manufacture. Power goes with the square of the supply, so at half the voltage it makes a quarter of the power and at twice the voltage it makes four times the power — which is how a heater is destroyed on its first run.

What isolation does a 220-240 V AC heater need?

Mains-rated insulation, a protective earth connection or a double-insulated construction, and creepage and clearance distances held between the element and any accessible surface. The construction is dielectric tested element-to-surface before it ships, and the test is a pass or fail rather than a working rating.

What is the maximum temperature of ksd9700 bimetal thermostats?

150 °C continuous, measured at the element. The limit belongs to the insulation system and not to the element alloy, so it is not a figure that can be extended by derating the power.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.