Skip to content
Polyimide (PI) Film Heaters · UL 499 / IEC 60335 / RoHS

Polyimide Heaters with Integrated NTC Sensor for 150-200 °C

Which insulation systems hold 150 °C to 200 °C continuously, what this construction is rated to, and the control and cut-out that hold the surface there.

Polyimide Heaters with Integrated NTC Sensor are rated 200 °C continuous, a limit set by the polyimide film, which covers 150 °C to 200 °C. The top of the flexible polymer range. Silicone rubber and polyimide both run continuously at 200 °C; above it both degrade, and no amount of derating changes that.

Working band
150 °C to 200 °C
Continuous limit, this construction
200 °C
Set by
Polyimide film
Watt density
0.5 W/cm² free air, 5 W/cm² bonded
Total thickness
0.35 mm
Maximum outline, one piece
300 x 500 mm (one piece)

The band is the temperature the heated surface has to hold, not the temperature the element reaches. The element always runs hotter, by an amount the watt density and the thermal path decide, so the cut-out is set against the element and not against the load.

Polyimide Heaters with Integrated NTC Sensor — the construction this guide is about

The 150 °c to 200 °c band is a material boundary, not a convention. The top of the flexible polymer range. Silicone rubber and polyimide both run continuously at 200 °C; above it both degrade, and no amount of derating changes that. This page covers what that means for polyimide heaters with integrated ntc sensor, which is rated to 200 °C continuous.

What the 150 °C to 200 °C Band Requires

The top of the flexible polymer range. Silicone rubber and polyimide both run continuously at 200 °C; above it both degrade, and no amount of derating changes that.

Band150 °C to 200 °C
This construction, continuous200 °C
Limited bypolyimide film

This band reaches the ceiling of the construction. At 200 °C there is no headroom left, so the control has to hold the set point rather than approach it from above, and the limit device has to be set where it can act before the insulation does. A duty that spends its time at the top of the band is a duty that should be quoted against the next construction up.

Why the Boundary Is Where It Is

200 °C is the top of the flexible polymer range. Silicone rubber and polyimide both run there continuously, and both degrade above it — silicone hardens and loses its tear strength, polyimide embrittles. No derating changes either.

Cross this line and the construction changes completely: fired thick film on stainless or alumina, or a mica-insulated element. Those parts are rigid, clamped and made to a different drawing, so the boundary is a redesign rather than a substitution.

What a Polyimide Heaters with Integrated NTC Sensor Is

The sensor laminated inside the heater rather than stuck on afterwards, so it reads the heated surface instead of the air near it.

A photo-etched copper or Inconel foil circuit laminated between polyimide films, 0.2 to 0.4 mm thick in total. It is the thinnest and fastest flexible heater made: almost no thermal mass of its own, so what it heats is the part rather than itself. With the sensor laminated inside the same stack, the control loop reads the heater rather than the air near it, which is what makes a fast heater controllable at all.

The heat leaves through the bonded face. Everything that is not in contact with the load radiates and convects from the back of the heater instead, which at these thicknesses is a poor path — so an air gap under part of the outline is not a small loss of efficiency, it is a hot spot at that spot.

Elementphoto-etched copper or Inconel foil
Insulation systempolyimide film
Total thickness0.35 mm
Maximum size, one piece300 x 500 mm (one piece)
Continuous working temperature200 °C

The continuous limit of 200 °C is set by polyimide film. The element alloy would run far hotter; it is never the element that decides.

Which Temperature Is Being Held

Three temperatures matter and they are not the same number: the element temperature, the temperature of the surface being heated, and the ambient. A heater rated for a continuous working temperature is rated at the element — the hottest point in the assembly, and the one nothing on the outside is measuring.

The gap between element and surface is the thermal path. Bonded to metal it may be a few degrees; across an air gap, a void in the adhesive or a dry clamped joint it can be tens of degrees, and every one of them appears at the element rather than at the load.

Which is why sensor position is a drawing item. A sensor laminated into the heater protects the heater; a sensor on the load controls the load. Assemblies that have to do both carry two: a control sensor where the process is, and a limit device against the element.

Attachment and Thermal Contact

Attachment options are a factory-applied pressure-sensitive adhesive, vulcanising or bonding to the customer's part, or mechanical clamping with a plate or a strap.

A PSA bond wants a clean, dry, degreased surface, continuous pressure while it wets out, and no trapped air: a bubble under the element is a spot with no thermal path, and it will be the first place the heater fails. Acrylic adhesives reach full strength over 24 to 72 hours, so the assembly is not at its rated watt density the moment it is pressed down.

On a 0.2 mm film the adhesive is a meaningful fraction of the total stack and of the thermal resistance. It is also the temperature limit of the assembly in most cases: acrylic PSA is comfortable to about 150 °C, well short of what the polyimide itself will take, so a 200 °C duty needs a silicone adhesive or a bond made by the customer.

From the capability table: Free, 3M PSA backing, or bonded with a two-part thermally conductive adhesive.

The bond line is part of the thermal circuit and should be specified like one. A 0.05 mm acrylic PSA layer conducts roughly 0.2 W/m·K; a filled silicone adhesive is two to five times better, and a bolted joint with an interface pad better again. Whatever is chosen, it has to be continuous — the heater cannot spread heat sideways to cover a gap, and the temperature under a void rises until something in the stack gives way.

Control and Protection

This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.

The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.

Sensors can be built into the part: NTC thermistor, PT100 or PT1000 RTD, or a K-type thermocouple, fitted under the same insulation and tested with the heater as one assembly. A sensor laminated into the heater reads the heater; a sensor on the load reads the load. Both are legitimate, and the drawing has to say which is wanted.

Where This Construction Is the Wrong Answer

  • Do not plan on running above 200 °C. That ceiling belongs to the insulation system, not to the element alloy, and it is not a figure that derating extends — past it the insulation degrades and the dielectric strength goes with it.
  • Do not specify polyimide for continuous steam or repeated autoclave cycles — it hydrolyses. Do not fold it to a tight radius, and do not put a sharp internal corner on the outline.
  • Do not rely on the insulation as a seal in a wet installation. Where washdown or condensation is expected, the assembly is sealed at the edge and at the lead exit, and both are drawing items.

Other Constructions That Hold 150 °C to 200 °C

Constructions in this catalogue that will hold 150 °c to 200 °c continuously:

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • An outline drawing, or a sketch with dimensions: overall size, holes, cut-outs, radii and the lead exit position.
  • The supply voltage, and whether it is AC or DC. The element is wound for one voltage; it is not a switchable range.
  • The power required, or — better — the temperature to be reached and the mass or flow it has to be reached in. Given the second, the wattage can be calculated instead of guessed.
  • What the heater is attached to, and how. This is what decides which watt density figure applies, and it is the question a quotation cannot proceed without.
  • The ambient, and the lowest temperature the assembly must start from. A heater sized for a 20 °C start is undersized for a -30 °C one.
  • Duty cycle: continuous, intermittent, or a warm-up to a deadline. Time to temperature is a specification, not a by-product.
  • Sensor and protection: which sensor, where it goes, and which limit device is fitted in series with the element.
  • The certification the end product is built to, named on the enquiry rather than after approval.
  • Quantity and target price, because the construction that is right for fifty pieces is often not the one that is right for fifty thousand.
  • Whether adhesive backing is wanted, and what surface it goes onto — a low-energy plastic needs a different adhesive from bare aluminium.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

Polyimide Heaters with Integrated NTC Sensor — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
ConstructionPhoto-etched copper or Inconel foil circuit laminated between polyimide films with a high temperature acrylic or FEP adhesiveDecided at quotation from the outline and the wattage
Insulation systemPolyimide film, 0.05 mm or 0.125 mm per faceThis is what sets the temperature limit, not the element
Total thickness0.35 mmNominal, before adhesive; add 0.2 mm for PSA backing
Minimum size10 x 10 mmBelow this the element cannot be routed with a safe edge margin
Maximum size, one piece300 x 500 mm (one piece)Larger areas are supplied as tiled zones with separate circuits
Dimensional toleranceu00b10.5 mm on dimensions up to 200 mmOn the die-cut outline; hole positions are held tighter
Supply voltage5 V DC to 240 V AC, wound to orderWound to the ordered voltage u2014 it is not a switchable range
Resistance toleranceu00b110% standard, u00b15% on requestMeasured at 20 u00b0C; hot resistance differs with the element alloy
Watt density, free air0.5 W/cmu00b2 typical, 0.8 W/cmu00b2 maximumNothing conducting heat away u2014 the honest figure for an unbonded heater
Watt density, bonded to heat sink5.0 W/cmu00b2 maximumOnly valid with full-area contact to metal; specifying at this figure and running in free air destroys the heater
Continuous working temperature-200 u00b0C to +200 u00b0C continuous (+220 u00b0C short term)Of the heater itself, measured at the element, not the ambient
Dielectric strength1500 V AC, 1 minute (2500 V AC on the 0.125 mm film build)One minute, element to any exposed surface, no breakdown
Insulation resistancegreater than 100 Mu03a9At 500 V DC, measured after the dielectric test
Lead wirePTFE or silicone insulated 24 AWG to 20 AWG, or an FFC tail etched as part of the circuitLength, gauge and termination to your drawing
AttachmentFree, 3M PSA backing, or bonded with a two-part thermally conductive adhesiveAdhesive-backed heaters need continuous contact pressure while curing
Sensor and control optionsNTC 10K B3950, PT100/PT1000, K-type thermocouple, KSD9700 bimetal thermostat, thermal cutoffFitted under the same insulation and tested as one assembly
Certifications availableUL 499 construction, IEC/EN 60335, UL 94 V-0, RoHS, REACH, CE, ISO 13485 QMSConstructions are built to these; the certificate covers the construction, not every outline
SensorNTC 10K B3950 u00b11%, PT100 or PT1000 class ALaminated between the films, its leads brought out in the same tail
PlacementCentre, edge or over a specified point of the circuitWhere the sensor sits decides what the control loop actually regulates

Capability figures are this factory's process limits for etched-foil polyimide construction. The 200 °C continuous limit and the watt density ceiling (to about 7.75 W/cm² with heat sinking) are properties of the polyimide film and the adhesive system, and are published consistently across the industry.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.

Build the Drawing

The panel above checks whether a size and a wattage can be built. This is the drawing itself: set the outline, route the heating track, place the lead wires, terminals, connector and temperature sensor, working in polyimide film, and turn the model to look at it. When it is right, export the 2D drawing as a PDF or a DXF and send it with your enquiry — a drawing is what a quotation for polyimide heaters with integrated ntc sensor is actually written from.

HEATING FILM DRAWING
Polyimide (PI / Kapton) Film Heater

Draw the outline, route the heating track, place the lead exits, terminals and sensor, dimension it, then export a PDF or a DXF and send it with your enquiry. Nothing here is a stock part and nothing you draw commits you to anything.

CMD

Want to compare constructions before you draw? Open the full builder, where every film family is selectable in one place.

Our facility

The numbers come off our own machines

Every unit is measured for resistance, held at its dielectric test voltage for a minute, and measured again for insulation resistance. Sample units from each lot are run under power and imaged. That is why the values on this page are quotable rather than indicative.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (UL 499 / IEC 60335 / RoHS)

ParameterSpecificationLimit / note
ConstructionPhoto-etched copper or Inconel foil circuit laminated between polyimide films with a high temperature acrylic or FEP adhesiveDecided at quotation from the outline and the wattage
Insulation systemPolyimide film, 0.05 mm or 0.125 mm per faceThis is what sets the temperature limit, not the element
Total thickness0.35 mmNominal, before adhesive; add 0.2 mm for PSA backing
Minimum size10 x 10 mmBelow this the element cannot be routed with a safe edge margin
Maximum size, one piece300 x 500 mm (one piece)Larger areas are supplied as tiled zones with separate circuits
Dimensional toleranceu00b10.5 mm on dimensions up to 200 mmOn the die-cut outline; hole positions are held tighter
Supply voltage5 V DC to 240 V AC, wound to orderWound to the ordered voltage u2014 it is not a switchable range
Resistance toleranceu00b110% standard, u00b15% on requestMeasured at 20 u00b0C; hot resistance differs with the element alloy
Watt density, free air0.5 W/cmu00b2 typical, 0.8 W/cmu00b2 maximumNothing conducting heat away u2014 the honest figure for an unbonded heater
Watt density, bonded to heat sink5.0 W/cmu00b2 maximumOnly valid with full-area contact to metal; specifying at this figure and running in free air destroys the heater
Continuous working temperature-200 u00b0C to +200 u00b0C continuous (+220 u00b0C short term)Of the heater itself, measured at the element, not the ambient
Dielectric strength1500 V AC, 1 minute (2500 V AC on the 0.125 mm film build)One minute, element to any exposed surface, no breakdown
Insulation resistancegreater than 100 Mu03a9At 500 V DC, measured after the dielectric test
Lead wirePTFE or silicone insulated 24 AWG to 20 AWG, or an FFC tail etched as part of the circuitLength, gauge and termination to your drawing
AttachmentFree, 3M PSA backing, or bonded with a two-part thermally conductive adhesiveAdhesive-backed heaters need continuous contact pressure while curing
Sensor and control optionsNTC 10K B3950, PT100/PT1000, K-type thermocouple, KSD9700 bimetal thermostat, thermal cutoffFitted under the same insulation and tested as one assembly
Certifications availableUL 499 construction, IEC/EN 60335, UL 94 V-0, RoHS, REACH, CE, ISO 13485 QMSConstructions are built to these; the certificate covers the construction, not every outline
SensorNTC 10K B3950 u00b11%, PT100 or PT1000 class ALaminated between the films, its leads brought out in the same tail
PlacementCentre, edge or over a specified point of the circuitWhere the sensor sits decides what the control loop actually regulates

Video: Polyimide Heaters with Integrated NTC Sensor for 150-200 °C

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

Which heaters work at 150 °c to 200 °c?

The top of the flexible polymer range. Silicone rubber and polyimide both run continuously at 200 °C; above it both degrade, and no amount of derating changes that.

Is the temperature rating the surface temperature or the element temperature?

The element temperature, which is the hottest point in the assembly and the one nothing on the outside is measuring. The surface being heated sits below it by whatever the thermal path costs — a few degrees through a good bond, tens of degrees across a void or a dry clamped joint.

What watt density can polyimide heaters with integrated ntc sensor run at?

0.5 W/cm² with nothing conducting the heat away, and 5 W/cm² bonded over its whole area to metal. The two figures describe two different installations, not a range to choose from: a heater specified at 5 W/cm² and then run in free air reaches its insulation limit within minutes.

What is the maximum temperature of polyimide heaters with integrated ntc sensor?

200 °C continuous, measured at the element. The limit belongs to polyimide film and not to the element alloy, so it is not a figure that can be extended by derating the power.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.