Instant Water Heating Thick Film Modules are rated 300 °C continuous, a limit set by the fired glass dielectric on the substrate, which covers 150 °C to 200 °C. The top of the flexible polymer range. Silicone rubber and polyimide both run continuously at 200 °C; above it both degrade, and no amount of derating changes that.

Working band
150 °C to 200 °C
Continuous limit, this construction
300 °C
Set by
Fired glass dielectric on the substrate
Watt density
20 W/cm² free air, 100 W/cm² bonded
Total thickness
2 mm to 4 mm
Maximum outline, one piece
150 x 300 mm

The band is the temperature the heated surface has to hold, not the temperature the element reaches. The element always runs hotter, by an amount the watt density and the thermal path decide, so the cut-out is set against the element and not against the load.

Instant Water Heating Thick Film Modules — the construction this guide is about

Instant Water Heating Thick Film Modules in the 150 °c to 200 °c band. The top of the flexible polymer range. Silicone rubber and polyimide both run continuously at 200 °C; above it both degrade, and no amount of derating changes that. The construction is rated 300 °C continuous, so this band sits inside its ceiling — and where a band sits relative to the ceiling is the whole of the selection argument.

What the 150 °C to 200 °C Band Requires

The top of the flexible polymer range. Silicone rubber and polyimide both run continuously at 200 °C; above it both degrade, and no amount of derating changes that.

Band150 °C to 200 °C
This construction, continuous300 °C
Limited byfired glass dielectric on the substrate

The band sits comfortably inside the 300 °C ceiling, which is where a heater should be specified: the margin between the working temperature and the insulation limit is what absorbs a poor thermal path, a warm ambient and a control overshoot without shortening the life of the part.

Why the Boundary Is Where It Is

200 °C is the top of the flexible polymer range. Silicone rubber and polyimide both run there continuously, and both degrade above it — silicone hardens and loses its tear strength, polyimide embrittles. No derating changes either.

Cross this line and the construction changes completely: fired thick film on stainless or alumina, or a mica-insulated element. Those parts are rigid, clamped and made to a different drawing, so the boundary is a redesign rather than a substitution.

What an Instant Water Heating Thick Film Modules Is

Flow-through heating modules for coffee machines, water dispensers and sanitary ware, where the water passes over the fired resistor with no tank and no warm-up.

Dielectric and resistor pastes screen printed onto stainless steel or alumina and fired at around 850 °C, then laser trimmed to resistance. There is no separate element and no interface: the heated surface is the substrate itself. In a fluid module the far face is the wetted wall, so the water carries the heat away as fast as the paste produces it — which is what allows watt densities an order of magnitude above any flexible construction, and what makes dry-run protection mandatory rather than advisable.

The heat leaves through a clamped joint, and a clamped joint is only as good as the pressure and the flatness behind it. A thermal interface material or a thin film of thermal grease fills the gaps that machining leaves; without one, contact happens at the high spots and the element runs hotter than the plate it is bolted to.

Elementfired resistor paste, laser trimmed
Insulation systemfired glass dielectric on the substrate
Total thickness2 mm to 4 mm
Maximum size, one piece150 x 300 mm
Continuous working temperature300 °C

The continuous limit of 300 °C is set by fired glass dielectric on the substrate. The element alloy would run far hotter; it is never the element that decides.

Which Temperature Is Being Held

Three temperatures matter and they are not the same number: the element temperature, the temperature of the surface being heated, and the ambient. A heater rated for a continuous working temperature is rated at the element — the hottest point in the assembly, and the one nothing on the outside is measuring.

The gap between element and surface is the thermal path. Bonded to metal it may be a few degrees; across an air gap, a void in the adhesive or a dry clamped joint it can be tens of degrees, and every one of them appears at the element rather than at the load.

Which is why sensor position is a drawing item. A sensor laminated into the heater protects the heater; a sensor on the load controls the load. Assemblies that have to do both carry two: a control sensor where the process is, and a limit device against the element.

Attachment and Thermal Contact

The part is clamped, not bonded. What matters at the joint is flatness, contact pressure and a thermal interface material to fill what machining leaves behind — a dry joint between two nominally flat surfaces touches on perhaps a few percent of its area.

Clamp evenly and to a torque, not to feel. A ceramic substrate in particular survives 400 °C far better than it survives one bolt pulled down harder than the other three.

From the capability table: Bolted, brazed or welded into the assembly; flatness of the mating face is critical.

The joint between the heated surface and the load carries every watt the element makes. Fill it: an interface pad, a thin film of thermal grease or a bonded assembly. Two dry surfaces bolted together are a thermal resistance, and that resistance appears as element temperature.

Control and Protection

This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.

The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.

On a fluid heater the limit device belongs on the substrate, close to the resistor, not downstream in the water. Downstream is where the temperature has already gone wrong; the substrate is where it goes wrong first, and at these watt densities the interval between the two is short.

Sensors can be built into the part: NTC thermistor, PT100 or PT1000 RTD, or a K-type thermocouple, fitted under the same insulation and tested with the heater as one assembly. A sensor laminated into the heater reads the heater; a sensor on the load reads the load. Both are legitimate, and the drawing has to say which is wanted.

Where This Construction Is the Wrong Answer

  • Do not plan on running above 300 °C. That ceiling belongs to the insulation system, not to the element alloy, and it is not a figure that derating extends — past it the insulation degrades and the dielectric strength goes with it.
  • Do not flex the substrate, clamp it unevenly, or accept a dented one. The fired glass dielectric is a brittle layer bonded to metal, and it cracks before anything visible happens to the plate.

Other Constructions That Hold 150 °C to 200 °C

Constructions in this catalogue that will hold 150 °c to 200 °c continuously:

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • An outline drawing, or a sketch with dimensions: overall size, holes, cut-outs, radii and the lead exit position.
  • The supply voltage, and whether it is AC or DC. The element is wound for one voltage; it is not a switchable range.
  • The power required, or — better — the temperature to be reached and the mass or flow it has to be reached in. Given the second, the wattage can be calculated instead of guessed.
  • What the heater is attached to, and how. This is what decides which watt density figure applies, and it is the question a quotation cannot proceed without.
  • The ambient, and the lowest temperature the assembly must start from. A heater sized for a 20 °C start is undersized for a -30 °C one.
  • Duty cycle: continuous, intermittent, or a warm-up to a deadline. Time to temperature is a specification, not a by-product.
  • Sensor and protection: which sensor, where it goes, and which limit device is fitted in series with the element.
  • The certification the end product is built to, named on the enquiry rather than after approval.
  • Quantity and target price, because the construction that is right for fifty pieces is often not the one that is right for fifty thousand.
  • The fluid, its flow rate and its inlet temperature, and how a dry-run condition is detected in your system.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

Instant Water Heating Thick Film Modules — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
ConstructionGlass dielectric and resistor pastes screen printed and fired onto the substrate, then laser trimmed to resistanceFired, bonded or encapsulated as a single assembly
Substrate304 stainless flow plateThe substrate carries the heat and the mechanical load
Thickness2 mm to 4 mmSubstrate plus element system
Maximum size, one piece150 x 300 mmLimited by the firing or curing fixture
Dimensional toleranceu00b10.2 mm on the substrate, u00b10.1 mm on printed featuresOn the machined substrate
Supply voltage12 V DC to 400 V ACCircuit is designed for the ordered voltage
Resistance toleranceu00b110% standard, u00b15% selectedThick film resistors are laser trimmed where a tighter band is required
Watt density20 W/cmu00b2 typical, 100 W/cmu00b2 maximum in a wetted applicationAchievable because the heat is generated in the surface being cooled
Maximum working temperature+300 u00b0C at the element systemOf the element system; the substrate itself tolerates more
Dielectric strength2500 V AC, 1 minuteOne minute, circuit to substrate
Insulation resistancegreater than 100 Mu03a9 at 500 V DCAt 500 V DC
TerminationsWelded tabs, crimp terminals or soldered leads depending on temperatureSoldered, welded or crimped as the temperature allows
MountingBolted, brazed or welded into the assembly; flatness of the mating face is criticalFlatness of the mating face matters more than clamping force
Sensor and control optionsPrinted PTC or NTC track, or a bonded thermocoupleIntegrated into the same firing or bonded to the substrate
Certifications availableUL 499, IEC/EN 60335, RoHS, REACH, CEConstruction level
Flow rate0.5 to 6 L/min depending on rise and powerPower required is 70 W per L/min per u00b0C of rise u2014 check the supply before the heater
Dry-run protectionMandatory: NTC or thermal cutoff on the outlet faceA dry thick film plate at 100 W/cmu00b2 fails in seconds, not minutes

Capability figures are this factory's process limits for fired thick film construction. Watt densities far above any flexible heater are achievable because the resistor is printed directly onto the surface being cooled — there is no interface and no adhesive in the heat path.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.

Build the Drawing

The panel above checks whether a size and a wattage can be built. This is the drawing itself: set the outline, route the heating track, place the lead wires, terminals, connector and temperature sensor, working in metal-clad thick film, and turn the model to look at it. When it is right, export the 2D drawing as a PDF or a DXF and send it with your enquiry — a drawing is what a quotation for instant water heating thick film modules is actually written from.

HEATING FILM DRAWING
Aluminium / Metal-Clad Thick Film Heater

Draw the outline, route the heating track, place the lead exits, terminals and sensor, dimension it, then export a PDF or a DXF and send it with your enquiry. Nothing here is a stock part and nothing you draw commits you to anything.

CMD

Want to compare constructions before you draw? Open the full builder, where every film family is selectable in one place.

Our facility

The numbers come off our own machines

Every unit is measured for resistance, held at its dielectric test voltage for a minute, and measured again for insulation resistance. Sample units from each lot are run under power and imaged. That is why the values on this page are quotable rather than indicative.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (UL 499 / IEC 60335 / RoHS)

ParameterSpecificationLimit / note
ConstructionGlass dielectric and resistor pastes screen printed and fired onto the substrate, then laser trimmed to resistanceFired, bonded or encapsulated as a single assembly
Substrate304 stainless flow plateThe substrate carries the heat and the mechanical load
Thickness2 mm to 4 mmSubstrate plus element system
Maximum size, one piece150 x 300 mmLimited by the firing or curing fixture
Dimensional toleranceu00b10.2 mm on the substrate, u00b10.1 mm on printed featuresOn the machined substrate
Supply voltage12 V DC to 400 V ACCircuit is designed for the ordered voltage
Resistance toleranceu00b110% standard, u00b15% selectedThick film resistors are laser trimmed where a tighter band is required
Watt density20 W/cmu00b2 typical, 100 W/cmu00b2 maximum in a wetted applicationAchievable because the heat is generated in the surface being cooled
Maximum working temperature+300 u00b0C at the element systemOf the element system; the substrate itself tolerates more
Dielectric strength2500 V AC, 1 minuteOne minute, circuit to substrate
Insulation resistancegreater than 100 Mu03a9 at 500 V DCAt 500 V DC
TerminationsWelded tabs, crimp terminals or soldered leads depending on temperatureSoldered, welded or crimped as the temperature allows
MountingBolted, brazed or welded into the assembly; flatness of the mating face is criticalFlatness of the mating face matters more than clamping force
Sensor and control optionsPrinted PTC or NTC track, or a bonded thermocoupleIntegrated into the same firing or bonded to the substrate
Certifications availableUL 499, IEC/EN 60335, RoHS, REACH, CEConstruction level
Flow rate0.5 to 6 L/min depending on rise and powerPower required is 70 W per L/min per u00b0C of rise u2014 check the supply before the heater
Dry-run protectionMandatory: NTC or thermal cutoff on the outlet faceA dry thick film plate at 100 W/cmu00b2 fails in seconds, not minutes

Video: Instant Water Heating Thick Film Modules for 150-200 °C

Thick Film Heater Element

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

Which heaters work at 150 °c to 200 °c?

The top of the flexible polymer range. Silicone rubber and polyimide both run continuously at 200 °C; above it both degrade, and no amount of derating changes that.

Is the temperature rating the surface temperature or the element temperature?

The element temperature, which is the hottest point in the assembly and the one nothing on the outside is measuring. The surface being heated sits below it by whatever the thermal path costs — a few degrees through a good bond, tens of degrees across a void or a dry clamped joint.

What watt density can instant water heating thick film modules run at?

20 W/cm² with nothing conducting the heat away, and 100 W/cm² bonded over its whole area to metal. The two figures describe two different installations, not a range to choose from: a heater specified at 100 W/cm² and then run in free air reaches its insulation limit within minutes.

What is the maximum temperature of instant water heating thick film modules?

300 °C continuous, measured at the element. The limit belongs to fired glass dielectric on the substrate and not to the element alloy, so it is not a figure that can be extended by derating the power.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.