Duty temperature decides the construction before anything else does. At 120 °c to 150 °c, epoxy immersion and tank heaters is a candidate; the sections below set out what it will hold, what has to be true for it to hold it, and what fails first when it does not.
What the 120 °C to 150 °C Band Requires
Process and platen heating, adhesive curing, epoxy-encapsulated plates at their limit. Silicone and polyimide are comfortable here; the encapsulant, not the element, is usually what constrains the design.
| Band | 120 °C to 150 °C |
|---|---|
| This construction, continuous | 150 °C |
| Limited by | thermally conductive filled epoxy |
This band reaches the ceiling of the construction. At 150 °C there is no headroom left, so the control has to hold the set point rather than approach it from above, and the limit device has to be set where it can act before the insulation does. A duty that spends its time at the top of the band is a duty that should be quoted against the next construction up.
Why the Boundary Is Where It Is
150 °C is the ceiling of filled epoxy, and on an encapsulated plate the encapsulant fails before either the element or the plate is troubled. It is also roughly where acrylic pressure-sensitive adhesives give up, which matters on any heater that is held on by its own adhesive rather than clamped.
Silicone and polyimide are comfortable through this band with 50 °C of margin in hand; the constraint is usually the bonding system, not the heater.
What an Epoxy Immersion and Tank Heaters Is
Chemically resistant encapsulated plates for plating, anodising and rinse tanks, where a bare element would be destroyed by the bath.
A resistance wire or foil element vacuum potted in thermally conductive filled epoxy against an aluminium or steel plate. Rigid, flat, sealed, and thermally bonded to its own plate so the heat leaves the element through metal rather than through air. In a tank the epoxy is also the chemical barrier, and it is the epoxy — at 150 °C — that sets the limit, not the element and not the plate.
The plate is the thermal path: the element is potted against it, so the metal spreads the heat before the load ever sees it. That is what buys uniformity, and it is also what makes the assembly slow — a bolted plate takes minutes to reach steady state where a film takes seconds.
| Element | resistance wire or foil, vacuum potted |
|---|---|
| Insulation system | thermally conductive filled epoxy |
| Total thickness | 8 mm to 20 mm |
| Maximum size, one piece | 300 x 800 mm |
| Continuous working temperature | 150 °C |
The continuous limit of 150 °C is set by thermally conductive filled epoxy. The element alloy would run far hotter; it is never the element that decides.
Which Temperature Is Being Held
Three temperatures matter and they are not the same number: the element temperature, the temperature of the surface being heated, and the ambient. A heater rated for a continuous working temperature is rated at the element — the hottest point in the assembly, and the one nothing on the outside is measuring.
The gap between element and surface is the thermal path. Bonded to metal it may be a few degrees; across an air gap, a void in the adhesive or a dry clamped joint it can be tens of degrees, and every one of them appears at the element rather than at the load.
Which is why sensor position is a drawing item. A sensor laminated into the heater protects the heater; a sensor on the load controls the load. Assemblies that have to do both carry two: a control sensor where the process is, and a limit device against the element.
Watt Density: the Two Figures
Watt density, not wattage, is what the construction is limited by. 0.3 W/cm² unbonded and 2 W/cm² bonded to metal are the limits for this build — so if the wattage is fixed by the duty, the area is what has to move.
Where the required power will not fit into the available area at the free-air figure, the answer is a better thermal path rather than a thinner margin: bond the whole face down, or add a spreader plate. On 150 cm² the difference is roughly 45 W against 3 W, which is usually the whole argument.
Control and Protection
This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.
The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.
The limit that matters is the epoxy's, at 150 °C, and it is reached at the element long before the plate face reads anything alarming. Put the limit device in the potting against the element, not on the outside of the plate.
Sensors can be built into the part: NTC thermistor, PT100 or PT1000 RTD, or a K-type thermocouple, fitted under the same insulation and tested with the heater as one assembly. A sensor laminated into the heater reads the heater; a sensor on the load reads the load. Both are legitimate, and the drawing has to say which is wanted.
How This Construction Fails
- Run at the bonded watt density in free air. The insulation reaches its limit within minutes and the element burns through where the local density is highest. Specify at 2 W/cm² only where the heater is genuinely bonded to metal over its whole area; unbonded, the figure is 0.3 W/cm².
- Loss of the control loop. An open-circuit sensor, a welded relay contact or a controller in manual leaves the element at full power with nothing watching it — the case the series thermal cutoff exists for, and the reason it must not be omitted to save a part.
- Overheating the encapsulant. The epoxy is the weakest link at 150 °C and it fails from the inside, where nothing is measuring; the plate face can look reasonable while the potting against the element is already cooking.
Other Constructions That Hold 120 °C to 150 °C
Constructions in this catalogue that will hold 120 °c to 150 °c continuously:
How to Specify One
This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:
- An outline drawing, or a sketch with dimensions: overall size, holes, cut-outs, radii and the lead exit position.
- The supply voltage, and whether it is AC or DC. The element is wound for one voltage; it is not a switchable range.
- The power required, or — better — the temperature to be reached and the mass or flow it has to be reached in. Given the second, the wattage can be calculated instead of guessed.
- What the heater is attached to, and how. This is what decides which watt density figure applies, and it is the question a quotation cannot proceed without.
- The ambient, and the lowest temperature the assembly must start from. A heater sized for a 20 °C start is undersized for a -30 °C one.
- Duty cycle: continuous, intermittent, or a warm-up to a deadline. Time to temperature is a specification, not a by-product.
- Sensor and protection: which sensor, where it goes, and which limit device is fitted in series with the element.
- The certification the end product is built to, named on the enquiry rather than after approval.
- Quantity and target price, because the construction that is right for fifty pieces is often not the one that is right for fifty thousand.
- The plate material, thickness and mounting hole pattern, and what the plate is bolted to.
Lead time: Samples 7-10 days from approved drawing; production 15-20 days.
Epoxy Immersion and Tank Heaters — Capability Table
These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.
| Parameter | Specification | Limit / note |
|---|---|---|
| Construction | Resistance wire or foil element potted in thermally conductive filled epoxy on a metal plate | Cured under vacuum so there are no voids in the heat path |
| Plate material | Titanium, 316L stainless or PTFE-clad | Aluminium for spreading, stainless where the chemistry demands it |
| Total thickness | 8 mm to 20 mm | Plate plus encapsulation |
| Maximum size, one piece | 300 x 800 mm | Larger plates are built as multiple circuits on one plate |
| Dimensional tolerance | u00b10.5 mm on the plate, u00b11 mm on the encapsulation | |
| Supply voltage | 110 V, 220 V, 380 V | Wound to order |
| Resistance tolerance | u00b110% | At 20 u00b0C |
| Watt density | 0.3 W/cmu00b2 typical, 2.0 W/cmu00b2 maximum | Against a load in contact; free-standing operation runs far lower |
| Continuous working temperature | -40 u00b0C to +150 u00b0C | Set by the epoxy, not by the element |
| Dielectric strength | 2500 V AC, 1 minute | Element to plate |
| Insulation resistance | greater than 100 Mu03a9 at 500 V DC | Also after 48 hours humidity conditioning |
| Ingress protection | IP65 as standard, IP67 with a moulded lead entry | The encapsulation is the seal |
| Mounting | Tapped holes, clearance holes, studs or bonded | Machined into the plate before potting |
| Sensor options | NTC, PT100 or thermostat potted into the same plate | Reads the plate, which is what the load actually sees |
| Certifications available | UL 499, IEC/EN 60335, RoHS, REACH, CE, IATF 16949 | Construction level |
| Chemical compatibility | Bath chemistry and temperature confirmed at quotation | The plate material is chosen for the bath u2014 there is no universal answer |
| Low level protection | Mandatory float or conductivity cutoff | An immersion heater out of the liquid is a fire, whatever it is potted in |
Capability figures are for resistance elements encapsulated in thermally conductive filled epoxy on a metal plate. The +150 °C continuous limit is a property of the encapsulant, and it is the lowest limit of any construction in this catalog — the element and the plate would both tolerate far more.