Skip to content
PTC Heaters · IEC 60335 / UL 499 / RoHS

RoHS & REACH PTC Aluminium Plate Heaters

What RoHS & REACH fixes, what it deliberately leaves to another document, and how it is evidenced on a heater built to a customer drawing.

Restriction of hazardous substances in the materials and the solder, and declaration of substances of very high concern. Required for anything sold into the EU.

Standard
RoHS & REACH
What it does not cover
A compliance declaration, not a safety approval.
Construction
PTC Aluminium Plate Heaters
Built and tested to
IEC 60335 / UL 499 / RoHS
Insulation
Aluminium carrier with insulating film
Continuous temperature limit
200 °C continuous

A construction is built and tested to a standard. A heater made to your outline has no certified part number of its own, so the approval sits with the end product and with the file you hold — what this factory supplies is the construction, the materials and the test records that let that file be assembled.

PTC Aluminium Plate Heaters — the construction this guide is about

RoHS & REACH as it applies to ptc aluminium plate heaters: what the document covers, what it deliberately leaves to someone else, and how a made-to-drawing heater is certified at all — which is not the same question as whether a part number is approved.

RoHS & REACH — Scope

Restriction of hazardous substances in the materials and the solder, and declaration of substances of very high concern. Required for anything sold into the EU.

What RoHS & REACH Does Not Cover

A compliance declaration, not a safety approval.

This is the division of labour to carry away from any heating standard: safety standards decide whether the part can hurt somebody, and say nothing about whether it holds a temperature, lasts five years or matches the last batch. Performance is a specification you write; safety is one the standard writes.

How a Made-to-Drawing Heater Is Certified

A construction is built and tested to a standard. The insulation system, the creepage and clearance distances, the earthing, the lead anchorage, the temperature under fault and the marking are what the test covers — and all of those are properties of the construction rather than of the outline it is die-cut to.

So a custom outline does not have a certificate of its own, and no supplier can honestly hand you one. What is available is the construction file: the standard the build is tested to, the materials list with their own ratings, and the test reports. That is what an approvals engineer needs, and it is what the end product's own certification is built on.

The practical consequence: name RoHS & REACH on the enquiry, not after approval. A construction chosen for cost and then asked to pass a standard afterwards usually has to be rebuilt, because the insulation thickness, the creepage distances and the lead anchorage are decided at design time and are not adjustable later.

From the capability table: UL 499, IEC/EN 60335, RoHS, REACH, CE, IATF 16949.

What a PTC Aluminium Plate Heaters Is

PTC elements bonded to a flat aluminium plate for conduction heating of a surface that must not be allowed to overshoot.

Barium titanate ceramic whose resistance rises steeply above its Curie point, so the power it draws falls as the surface approaches that temperature. The element cannot exceed the Curie point it was made to, whatever the supply or the control does. Bonded to an aluminium plate the ceramic is spread out into a uniform surface, and the plate is also what carries the heat away — an element clamped to nothing regulates itself down to almost no power at all.

The heat leaves through a clamped joint, and a clamped joint is only as good as the pressure and the flatness behind it. A thermal interface material or a thin film of thermal grease fills the gaps that machining leaves; without one, contact happens at the high spots and the element runs hotter than the plate it is bolted to.

Elementbarium titanate PTC ceramic
Insulation systemaluminium carrier with insulating film
Total thicknessElement 1.5 mm to 3 mm; assembly to your drawing
Maximum size, one piece40 x 60 mm to 200 x 300 mm
Continuous working temperature200 °C

The continuous limit of 200 °C is set by aluminium carrier with insulating film. The element alloy would run far hotter; it is never the element that decides.

The Other Standards This Construction Is Built To

A heater is rarely governed by one document. This construction is also built and tested to:

Safety, materials, substances and quality system are four separate questions with four separate documents behind them. A part can satisfy all four and still be the wrong heater for the duty, which is what the rest of this page is about.

Control and Protection

This is the one construction here that limits its own temperature. Above the Curie point the ceramic's resistance rises steeply, the current falls, and the element settles rather than climbing — so a PTC heater cannot thermally run away even with the control shorted out.

That is a safety property, not an accuracy one. Self-regulation holds a surface somewhere near the Curie point under whatever cooling it happens to have; it does not hold a set point, and the temperature it settles at moves with airflow, with supply voltage and with the load. Where a number has to be held, a sensor and a controller are still required.

Two things still have to be designed for: the inrush, which is several times the running current while the ceramic is cold and which the supply and any switching device must tolerate, and the electrical fault case, which self-regulation does nothing about — a fuse or a current-limited supply is still the protection against a short.

Watt Density: the Two Figures

Two watt densities are quoted because there are two thermal situations. With nothing conducting heat away, 0.8 W/cm² is what the insulation survives. Bonded to a heat sink over the full outline, 4 W/cm² is. Anything in between depends on the quality of the joint, and the joint is the customer's to make.

The failure is silent and quick: the element does not know how it is mounted, so at 4 W/cm² in free air the heat simply accumulates in the insulation until it degrades. This is the single most common way these heaters are destroyed, and it happens on the first run rather than after a year.

A PTC assembly behaves differently at the limit. Deprived of its heat sink it does not run away; it reduces its own power. The consequence of a poor thermal path here is a heater that delivers well under its nameplate power, not one that destroys itself.

Leads and Terminations

Termination is specified on the drawing: lead length, gauge, insulation and the connector or tag at the end of it.

Connector and termination options: Faston 2.8/4.8 mm, crimp, or flying leads. A keyed housing removes a soldering operation from the customer's line and removes the possibility of the assembly being connected backwards; on a heater with a separate sensor circuit it also stops the sensor pair being mistaken for the power pair.

The lead exit is a thermal discontinuity as well as an electrical one. The joint between a fine element and a stranded lead is the hottest point of many heaters, so it is kept out of the highest watt density zone, strain relieved, and — where the exit sits in a hot area — insulated in PTFE rather than in silicone.

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • An outline drawing, or a sketch with dimensions: overall size, holes, cut-outs, radii and the lead exit position.
  • The supply voltage, and whether it is AC or DC. The element is wound for one voltage; it is not a switchable range.
  • The power required, or — better — the temperature to be reached and the mass or flow it has to be reached in. Given the second, the wattage can be calculated instead of guessed.
  • What the heater is attached to, and how. This is what decides which watt density figure applies, and it is the question a quotation cannot proceed without.
  • The ambient, and the lowest temperature the assembly must start from. A heater sized for a 20 °C start is undersized for a -30 °C one.
  • Duty cycle: continuous, intermittent, or a warm-up to a deadline. Time to temperature is a specification, not a by-product.
  • Sensor and protection: which sensor, where it goes, and which limit device is fitted in series with the element.
  • The certification the end product is built to, named on the enquiry rather than after approval.
  • Quantity and target price, because the construction that is right for fifty pieces is often not the one that is right for fifty thousand.
  • The Curie point wanted, and the airflow or thermal path the assembly will have — both decide the power the element will actually deliver.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

PTC Aluminium Plate Heaters — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
ConstructionBarium titanate PTC ceramic, electroded on both faces, in an aluminium carrierAssembly built around the element to suit the load
Curie temperature+60 u00b0C to +200 u00b0C, selectedSelected at order u2014 it is the surface temperature ceiling and cannot be adjusted afterwards
Self-regulationPower falls to a fraction of rated as the surface reaches the Curie pointNo thermostat is required to prevent runaway; one may still be wanted for control
Element size40 x 60 mm to 200 x 300 mmStandard element footprints; assemblies to your drawing
Supply voltage12 V, 24 V, 48 V, 110 V, 220 VThe same element works over a voltage band with different output
Power output0.8 W/cmu00b2 typical in still air, 4.0 W/cmu00b2 with forced airOutput is set by the airflow, not by a setting u2014 this is what self-regulating means
Inrush current3 to 8 times running current for 1 to 3 secondsThe supply and any relay or MOSFET must tolerate it
Dielectric strength1800 V AC, 1 minute, element to caseOn the assembled unit with its insulation in place
Insulation resistancegreater than 100 Mu03a9 at 500 V DC
TerminationsFaston 2.8/4.8 mm, crimp, or flying leadsChosen for the assembly temperature
LifeOver 10,000 hours at rated conditionsAgeing shows as a slow rise in cold resistance, not as sudden failure
Certifications availableUL 499, IEC/EN 60335, RoHS, REACH, CE, IATF 16949Construction level
Surface temperatureSettles near the Curie point regardless of loadWhich is why this is chosen for a surface a person or a plastic part can touch

Capability figures are for barium titanate PTC ceramic elements and the aluminium assemblies built around them. The defining property — that power falls steeply as the element approaches its Curie point, so surface temperature cannot run away — is inherent to the ceramic, not a feature of the control.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.

Build the Drawing

The panel above checks whether a size and a wattage can be built. This is the drawing itself: set the outline, route the heating track, place the lead wires, terminals, connector and temperature sensor, working in PET / PTC film, and turn the model to look at it. When it is right, export the 2D drawing as a PDF or a DXF and send it with your enquiry — a drawing is what a quotation for ptc aluminium plate heaters is actually written from.

HEATING FILM DRAWING
PET / PTC Film Heater

Draw the outline, route the heating track, place the lead exits, terminals and sensor, dimension it, then export a PDF or a DXF and send it with your enquiry. Nothing here is a stock part and nothing you draw commits you to anything.

CMD

Want to compare constructions before you draw? Open the full builder, where every film family is selectable in one place.

Our facility

Held in production, not just on paper

The limits above are the ones our own lamination press, die and test lines actually hold, and every unit is tested rather than a sample. A figure is only worth quoting if it survives the process that produces it.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (IEC 60335 / UL 499 / RoHS)

ParameterSpecificationLimit / note
ConstructionBarium titanate PTC ceramic, electroded on both faces, in an aluminium carrierAssembly built around the element to suit the load
Curie temperature+60 u00b0C to +200 u00b0C, selectedSelected at order u2014 it is the surface temperature ceiling and cannot be adjusted afterwards
Self-regulationPower falls to a fraction of rated as the surface reaches the Curie pointNo thermostat is required to prevent runaway; one may still be wanted for control
Element size40 x 60 mm to 200 x 300 mmStandard element footprints; assemblies to your drawing
Supply voltage12 V, 24 V, 48 V, 110 V, 220 VThe same element works over a voltage band with different output
Power output0.8 W/cmu00b2 typical in still air, 4.0 W/cmu00b2 with forced airOutput is set by the airflow, not by a setting u2014 this is what self-regulating means
Inrush current3 to 8 times running current for 1 to 3 secondsThe supply and any relay or MOSFET must tolerate it
Dielectric strength1800 V AC, 1 minute, element to caseOn the assembled unit with its insulation in place
Insulation resistancegreater than 100 Mu03a9 at 500 V DC
TerminationsFaston 2.8/4.8 mm, crimp, or flying leadsChosen for the assembly temperature
LifeOver 10,000 hours at rated conditionsAgeing shows as a slow rise in cold resistance, not as sudden failure
Certifications availableUL 499, IEC/EN 60335, RoHS, REACH, CE, IATF 16949Construction level
Surface temperatureSettles near the Curie point regardless of loadWhich is why this is chosen for a surface a person or a plastic part can touch

Video: RoHS & REACH PTC Aluminium Plate Heaters

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

What is the maximum temperature of ptc aluminium plate heaters?

200 °C continuous, measured at the element. The limit belongs to aluminium carrier with insulating film and not to the element alloy, so it is not a figure that can be extended by derating the power.

Does a PTC heater need a thermostat?

Not to prevent a runaway: above its Curie point the ceramic's resistance rises steeply and the power falls, so it cannot exceed that temperature whatever the control does. It does need a sensor and a controller if a set point has to be held accurately — self-regulation bounds the temperature, it does not hold a value — and it still needs a fuse, because self-regulation does nothing about an electrical fault.

How large can one piece be?

40 x 60 mm to 200 x 300 mm in a single piece. Larger areas are supplied as tiled zones with separate circuits, which is usually better engineering anyway: separate zones can be controlled separately, and a large single circuit has to carry the whole current at one lead exit.

Is this heater RoHS & REACH approved?

The construction is built and tested to RoHS & REACH; the outline is yours, and a made-to-drawing outline does not carry a certificate of its own. What is available is the construction file — the standard the build is tested to, the material ratings and the test reports — which is what your own product approval is built on.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.