Certification page for battery polyimide film heaters under ISO 13485. The quality management system standard for medical devices, and the one a heater destined for a diagnostic instrument or a patient-warming device is built under.
ISO 13485 — Scope
The quality management system standard for medical devices, and the one a heater destined for a diagnostic instrument or a patient-warming device is built under.
What ISO 13485 Does Not Cover
Not a device approval; the device manufacturer still carries the regulatory submission.
This is the division of labour to carry away from any heating standard: safety standards decide whether the part can hurt somebody, and say nothing about whether it holds a temperature, lasts five years or matches the last batch. Performance is a specification you write; safety is one the standard writes.
It is also a certification of the factory rather than of the part. It says how the part is controlled, documented and traced; it does not say the part is fit for your application, and it does not carry your regulatory submission for you.
How a Made-to-Drawing Heater Is Certified
A construction is built and tested to a standard. The insulation system, the creepage and clearance distances, the earthing, the lead anchorage, the temperature under fault and the marking are what the test covers — and all of those are properties of the construction rather than of the outline it is die-cut to.
So a custom outline does not have a certificate of its own, and no supplier can honestly hand you one. What is available is the construction file: the standard the build is tested to, the materials list with their own ratings, and the test reports. That is what an approvals engineer needs, and it is what the end product's own certification is built on.
The practical consequence: name ISO 13485 on the enquiry, not after approval. A construction chosen for cost and then asked to pass a standard afterwards usually has to be rebuilt, because the insulation thickness, the creepage distances and the lead anchorage are decided at design time and are not adjustable later.
From the capability table: UL 499 construction, IEC/EN 60335, UL 94 V-0, RoHS, REACH, CE, ISO 13485 QMS.
What a Battery Polyimide Film Heaters Is
Ultra-thin PI heaters for cell surfaces and pouch cells, where the 1.5 mm of a silicone heater would not fit between the cell and the module wall.
A photo-etched copper or Inconel foil circuit laminated between polyimide films, 0.2 to 0.4 mm thick in total. It is the thinnest and fastest flexible heater made: almost no thermal mass of its own, so what it heats is the part rather than itself. It will wrap a cylinder; it will not take a compound curve, and a nick in a 0.05 mm film propagates from the edge, so outlines are drawn with radiused corners.
The heat leaves through the bonded face. Everything that is not in contact with the load radiates and convects from the back of the heater instead, which at these thicknesses is a poor path — so an air gap under part of the outline is not a small loss of efficiency, it is a hot spot at that spot.
| Element | photo-etched copper or Inconel foil |
|---|---|
| Insulation system | polyimide film |
| Total thickness | 0.2 mm |
| Maximum size, one piece | 300 x 500 mm (one piece) |
| Continuous working temperature | 200 °C |
The continuous limit of 200 °C is set by polyimide film. The element alloy would run far hotter; it is never the element that decides.
Other Constructions Built to ISO 13485
Control and Protection
This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.
The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.
Sensors can be built into the part: NTC thermistor, PT100 or PT1000 RTD, or a K-type thermocouple, fitted under the same insulation and tested with the heater as one assembly. A sensor laminated into the heater reads the heater; a sensor on the load reads the load. Both are legitimate, and the drawing has to say which is wanted.
Watt Density: the Two Figures
Watt density, not wattage, is what the construction is limited by. 0.3 W/cm² unbonded and 2 W/cm² bonded to metal are the limits for this build — so if the wattage is fixed by the duty, the area is what has to move.
Where the required power will not fit into the available area at the free-air figure, the answer is a better thermal path rather than a thinner margin: bond the whole face down, or add a spreader plate. On 150 cm² the difference is roughly 45 W against 3 W, which is usually the whole argument.
Leads and Terminations
Lead wire as supplied: PTFE or silicone insulated 24 AWG to 20 AWG, or an FFC tail etched as part of the circuit. Length, gauge, exit position and termination are drawing items — the exit position in particular, because it decides where the heater can be routed and it cannot be changed after the tool is cut.
The lead exit is a thermal discontinuity as well as an electrical one. The joint between a fine element and a stranded lead is the hottest point of many heaters, so it is kept out of the highest watt density zone, strain relieved, and — where the exit sits in a hot area — insulated in PTFE rather than in silicone.
On a 0.2 mm film the lead joint is thicker than the heater. Where the assembly has to stay flat, the leads are brought out to a tail or a flat flexible tab rather than soldered onto the heated area.
How to Specify One
This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:
- An outline drawing, or a sketch with dimensions: overall size, holes, cut-outs, radii and the lead exit position.
- The supply voltage, and whether it is AC or DC. The element is wound for one voltage; it is not a switchable range.
- The power required, or — better — the temperature to be reached and the mass or flow it has to be reached in. Given the second, the wattage can be calculated instead of guessed.
- What the heater is attached to, and how. This is what decides which watt density figure applies, and it is the question a quotation cannot proceed without.
- The ambient, and the lowest temperature the assembly must start from. A heater sized for a 20 °C start is undersized for a -30 °C one.
- Duty cycle: continuous, intermittent, or a warm-up to a deadline. Time to temperature is a specification, not a by-product.
- Sensor and protection: which sensor, where it goes, and which limit device is fitted in series with the element.
- The certification the end product is built to, named on the enquiry rather than after approval.
- Quantity and target price, because the construction that is right for fifty pieces is often not the one that is right for fifty thousand.
- Whether adhesive backing is wanted, and what surface it goes onto — a low-energy plastic needs a different adhesive from bare aluminium.
Lead time: Samples 7-10 days from approved drawing; production 15-20 days.
Battery Polyimide Film Heaters — Capability Table
These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.
| Parameter | Specification | Limit / note |
|---|---|---|
| Construction | Photo-etched copper or Inconel foil circuit laminated between polyimide films with a high temperature acrylic or FEP adhesive | Decided at quotation from the outline and the wattage |
| Insulation system | Polyimide film, 0.05 mm or 0.125 mm per face | This is what sets the temperature limit, not the element |
| Total thickness | 0.2 mm | Nominal, before adhesive; add 0.2 mm for PSA backing |
| Minimum size | 10 x 10 mm | Below this the element cannot be routed with a safe edge margin |
| Maximum size, one piece | 300 x 500 mm (one piece) | Larger areas are supplied as tiled zones with separate circuits |
| Dimensional tolerance | u00b10.5 mm on dimensions up to 200 mm | On the die-cut outline; hole positions are held tighter |
| Supply voltage | 5 V DC to 240 V AC, wound to order | Wound to the ordered voltage u2014 it is not a switchable range |
| Resistance tolerance | u00b110% standard, u00b15% on request | Measured at 20 u00b0C; hot resistance differs with the element alloy |
| Watt density, free air | 0.3 W/cmu00b2 typical, 0.5 W/cmu00b2 maximum | Nothing conducting heat away u2014 the honest figure for an unbonded heater |
| Watt density, bonded to heat sink | 2.0 W/cmu00b2 maximum | Only valid with full-area contact to metal; specifying at this figure and running in free air destroys the heater |
| Continuous working temperature | -200 u00b0C to +200 u00b0C continuous (+220 u00b0C short term) | Of the heater itself, measured at the element, not the ambient |
| Dielectric strength | 1500 V AC, 1 minute (2500 V AC on the 0.125 mm film build) | One minute, element to any exposed surface, no breakdown |
| Insulation resistance | greater than 100 Mu03a9 | At 500 V DC, measured after the dielectric test |
| Lead wire | PTFE or silicone insulated 24 AWG to 20 AWG, or an FFC tail etched as part of the circuit | Length, gauge and termination to your drawing |
| Attachment | Free, 3M PSA backing, or bonded with a two-part thermally conductive adhesive | Adhesive-backed heaters need continuous contact pressure while curing |
| Sensor and control options | NTC 10K B3950, PT100/PT1000, K-type thermocouple, KSD9700 bimetal thermostat, thermal cutoff | Fitted under the same insulation and tested as one assembly |
| Certifications available | UL 499 construction, IEC/EN 60335, UL 94 V-0, RoHS, REACH, CE, ISO 13485 QMS | Constructions are built to these; the certificate covers the construction, not every outline |
| Watt density limit | 0.3 W/cmu00b2 typical against a cell face | A cell is not a heat sink; it is the thing being protected from a hot spot |
| Compression | Survives module stack pressure to 1 MPa | The circuit is flat and the film does not creep, unlike a wound element |
Capability figures are this factory's process limits for etched-foil polyimide construction. The 200 °C continuous limit and the watt density ceiling (to about 7.75 W/cm² with heat sinking) are properties of the polyimide film and the adhesive system, and are published consistently across the industry.