Skip to content
Polyimide (PI) Film Heaters · UL 499 / IEC 60335 / RoHS

110-120 V AC Etched Foil Polyimide Heaters

How this construction is wound for 110-120 V AC, with the watt density limits in free air and bonded, the temperature the insulation holds continuously, the control and cut-out the design has to carry and what the drawing has to state.

110-120 V AC Etched Foil Polyimide Heaters: continuous limit 200 °C continuous, watt density 0.8 W/cm² free air, 7.5 W/cm² bonded, total thickness 0.2 mm. At 110 V every 100 W of element power draws about 0.9 A, so the lead gauge, the connector and the switching device are sized from the wattage before anything else is decided. At mains potential the construction needs mains-rated insulation, a protective earth or double insulation, and a hi-pot and leakage test on every piece.

Supply
110-120 V AC
Element
Photo-etched copper or Inconel foil
Insulation
Polyimide film
Continuous temperature limit
200 °C continuous
Watt density
0.8 W/cm² free air, 7.5 W/cm² bonded
Total thickness
0.2 mm

The element is wound to a resistance, so power follows the square of the supply: the same part on 240 V instead of 220 V makes about 19% more heat. The supply voltage is a drawing item, not a preference, and a heater wound for one voltage is not derated onto another.

Etched Foil Polyimide Heaters — the construction this guide is about

What 110-120 V AC means for etched foil polyimide heaters: at 110-120 V AC, power follows P = V²/R, so a 500 W element is 24.2 Ω and draws 4.55 A. Everything downstream of that — conductor gauge, connector rating, the switching device and the isolation the assembly needs — follows from those two numbers.

The Element at 110-120 V AC

Two equations do all the work: P = V²/R and I = P/V. At 110-120 V AC, 500 W is 24.2 Ω and 4.55 A.

Worked example500 W at 110-120 V AC
Element resistance, R = V²/P24.2 Ω
Current, I = P/V4.55 A

The span matters more than the example. At 110-120 V AC a 20 W element is 605 Ω and a 500 W element is 24.2 Ω — a factor of twenty-five in resistance, met by changing the conductor cross-section and the length of the path, both of which are constrained by the outline.

At mains voltage the difficulty is the opposite one. Current is modest — 4.55 A for the worked example — but the element is a long, fine conductor, and a low-wattage heater at 110-120 V AC is the hardest thing in this catalogue to build: 20 W means 605 Ω, which is a very long track to fit inside a small outline without the pitch becoming so tight that adjacent runs interact.

Where the arithmetic will not fit the outline, the usual answers are a lower supply voltage with a small power supply behind it, several circuits in series, or a different construction entirely. What does not work is thinning the conductor further: the track becomes the fuse.

Resistance tolerance is u00b110% standard, u00b15% on request, and power follows resistance inversely: a u00b110% standard, u00b15% on request tolerance band is the same band on the delivered wattage. Where the wattage matters — a warm-up to a deadline, a pack of heaters that must match — say so on the enquiry and the tighter band is selected and tested.

Isolation, Earthing and Safety Class

110-120 V AC is a mains supply, and the construction is built to match: mains-rated insulation, a protective earth connection or a double-insulated build, and creepage and clearance distances held between the element and any accessible surface.

Leakage current is the figure that surprises people. A large heated area behaves as a distributed capacitance to earth, so a big mains heater has a measurable leakage even when it is perfectly sound, and an RCD protecting several of them can trip on the sum. Where several elements share a circuit, allow for the total.

Dielectric withstand1500 V AC, 1 minute (2500 V AC on the 0.125 mm film build)
Insulation resistancegreater than 100 Mu03a9

Every heater is tested to these before it ships, element to any exposed surface. A dielectric test is a pass or a fail, not a measurement — a part that passes at 2500 V is not one that may be run at 2500 V.

What an Etched Foil Polyimide Heaters Is

Precision-etched circuits with varied trace width across the outline, for temperature uniformity better than ±1 °C on instrument and optical assemblies.

A photo-etched copper or Inconel foil circuit laminated between polyimide films, 0.2 to 0.4 mm thick in total. It is the thinnest and fastest flexible heater made: almost no thermal mass of its own, so what it heats is the part rather than itself. It will wrap a cylinder; it will not take a compound curve, and a nick in a 0.05 mm film propagates from the edge, so outlines are drawn with radiused corners.

The heat leaves through the bonded face. Everything that is not in contact with the load radiates and convects from the back of the heater instead, which at these thicknesses is a poor path — so an air gap under part of the outline is not a small loss of efficiency, it is a hot spot at that spot.

Elementphoto-etched copper or Inconel foil
Insulation systempolyimide film
Total thickness0.2 mm
Maximum size, one piece300 x 500 mm (one piece)
Continuous working temperature200 °C

The continuous limit of 200 °C is set by polyimide film. The element alloy would run far hotter; it is never the element that decides.

Switching an AC Element

AC switching has a zero crossing to hide behind. A zero-cross solid state relay makes and breaks at the crossing, which all but removes the switching transient and the conducted emissions that go with it — worth having on any installation that also has to pass an EMC test.

Control by burst firing — whole cycles on, whole cycles off, over a period of a second or more — rather than by phase angle. Burst firing generates almost no harmonics; phase angle control chops the waveform and is the reason a heater ends up in the EMC report at all. A heater has enough thermal inertia that a one-second period is invisible at the surface.

Size the relay for the inrush, not the running current, and heatsink it: a triac or SSR drops around one volt per amp of load, and that is real power to be got rid of inside the panel.

Attachment and Thermal Contact

Attachment options are a factory-applied pressure-sensitive adhesive, vulcanising or bonding to the customer's part, or mechanical clamping with a plate or a strap.

A PSA bond wants a clean, dry, degreased surface, continuous pressure while it wets out, and no trapped air: a bubble under the element is a spot with no thermal path, and it will be the first place the heater fails. Acrylic adhesives reach full strength over 24 to 72 hours, so the assembly is not at its rated watt density the moment it is pressed down.

On a 0.2 mm film the adhesive is a meaningful fraction of the total stack and of the thermal resistance. It is also the temperature limit of the assembly in most cases: acrylic PSA is comfortable to about 150 °C, well short of what the polyimide itself will take, so a 200 °C duty needs a silicone adhesive or a bond made by the customer.

From the capability table: Free, 3M PSA backing, or bonded with a two-part thermally conductive adhesive.

The bond line is part of the thermal circuit and should be specified like one. A 0.05 mm acrylic PSA layer conducts roughly 0.2 W/m·K; a filled silicone adhesive is two to five times better, and a bolted joint with an interface pad better again. Whatever is chosen, it has to be continuous — the heater cannot spread heat sideways to cover a gap, and the temperature under a void rises until something in the stack gives way.

Leads and Terminations

Lead wire as supplied: PTFE or silicone insulated 24 AWG to 20 AWG, or an FFC tail etched as part of the circuit. Length, gauge, exit position and termination are drawing items — the exit position in particular, because it decides where the heater can be routed and it cannot be changed after the tool is cut.

The lead exit is a thermal discontinuity as well as an electrical one. The joint between a fine element and a stranded lead is the hottest point of many heaters, so it is kept out of the highest watt density zone, strain relieved, and — where the exit sits in a hot area — insulated in PTFE rather than in silicone.

On a 0.2 mm film the lead joint is thicker than the heater. Where the assembly has to stay flat, the leads are brought out to a tail or a flat flexible tab rather than soldered onto the heated area.

Control and Protection

This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.

The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.

Sensors can be built into the part: NTC thermistor, PT100 or PT1000 RTD, or a K-type thermocouple, fitted under the same insulation and tested with the heater as one assembly. A sensor laminated into the heater reads the heater; a sensor on the load reads the load. Both are legitimate, and the drawing has to say which is wanted.

How This Construction Fails

  • Run at the bonded watt density in free air. The insulation reaches its limit within minutes and the element burns through where the local density is highest. Specify at 7.5 W/cm² only where the heater is genuinely bonded to metal over its whole area; unbonded, the figure is 0.8 W/cm².
  • Voids under the bond. Air trapped during application, a contaminated surface or an adhesive that never reached full cure all produce the same result: a patch with no thermal path, running far above the rest of the heater, which is where the failure starts.
  • Loss of the control loop. An open-circuit sensor, a welded relay contact or a controller in manual leaves the element at full power with nothing watching it — the case the series thermal cutoff exists for, and the reason it must not be omitted to save a part.
  • A nick in the film. Polyimide tears from a defect at the edge, so sharp internal corners and hand-trimmed outlines both propagate. It also hydrolyses in continuous steam, which rules out sterilisation duty for the bare film.

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • An outline drawing, or a sketch with dimensions: overall size, holes, cut-outs, radii and the lead exit position.
  • The supply voltage, and whether it is AC or DC. The element is wound for one voltage; it is not a switchable range.
  • The power required, or — better — the temperature to be reached and the mass or flow it has to be reached in. Given the second, the wattage can be calculated instead of guessed.
  • What the heater is attached to, and how. This is what decides which watt density figure applies, and it is the question a quotation cannot proceed without.
  • The ambient, and the lowest temperature the assembly must start from. A heater sized for a 20 °C start is undersized for a -30 °C one.
  • Duty cycle: continuous, intermittent, or a warm-up to a deadline. Time to temperature is a specification, not a by-product.
  • Sensor and protection: which sensor, where it goes, and which limit device is fitted in series with the element.
  • The certification the end product is built to, named on the enquiry rather than after approval.
  • Quantity and target price, because the construction that is right for fifty pieces is often not the one that is right for fifty thousand.
  • Whether adhesive backing is wanted, and what surface it goes onto — a low-energy plastic needs a different adhesive from bare aluminium.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

Etched Foil Polyimide Heaters — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
ConstructionPhoto-etched copper or Inconel foil circuit laminated between polyimide films with a high temperature acrylic or FEP adhesiveDecided at quotation from the outline and the wattage
Insulation systemPolyimide film, 0.05 mm or 0.125 mm per faceThis is what sets the temperature limit, not the element
Total thickness0.2 mmNominal, before adhesive; add 0.2 mm for PSA backing
Minimum size10 x 10 mmBelow this the element cannot be routed with a safe edge margin
Maximum size, one piece300 x 500 mm (one piece)Larger areas are supplied as tiled zones with separate circuits
Dimensional toleranceu00b10.5 mm on dimensions up to 200 mmOn the die-cut outline; hole positions are held tighter
Supply voltage5 V DC to 240 V AC, wound to orderWound to the ordered voltage u2014 it is not a switchable range
Resistance toleranceu00b110% standard, u00b15% on requestMeasured at 20 u00b0C; hot resistance differs with the element alloy
Watt density, free air0.8 W/cmu00b2 typical, 1.3 W/cmu00b2 maximumNothing conducting heat away u2014 the honest figure for an unbonded heater
Watt density, bonded to heat sink7.5 W/cmu00b2 maximumOnly valid with full-area contact to metal; specifying at this figure and running in free air destroys the heater
Continuous working temperature-200 u00b0C to +200 u00b0C continuous (+220 u00b0C short term)Of the heater itself, measured at the element, not the ambient
Dielectric strength1500 V AC, 1 minute (2500 V AC on the 0.125 mm film build)One minute, element to any exposed surface, no breakdown
Insulation resistancegreater than 100 Mu03a9At 500 V DC, measured after the dielectric test
Lead wirePTFE or silicone insulated 24 AWG to 20 AWG, or an FFC tail etched as part of the circuitLength, gauge and termination to your drawing
AttachmentFree, 3M PSA backing, or bonded with a two-part thermally conductive adhesiveAdhesive-backed heaters need continuous contact pressure while curing
Sensor and control optionsNTC 10K B3950, PT100/PT1000, K-type thermocouple, KSD9700 bimetal thermostat, thermal cutoffFitted under the same insulation and tested as one assembly
Certifications availableUL 499 construction, IEC/EN 60335, UL 94 V-0, RoHS, REACH, CE, ISO 13485 QMSConstructions are built to these; the certificate covers the construction, not every outline
Uniformityu00b11 u00b0C achievable over the heated area with a profiled circuitAchieved by trace geometry, and it is designed per outline
Circuit toleranceTrace width held to u00b10.05 mmWhich is what makes the resistance repeatable from lot to lot

Capability figures are this factory's process limits for etched-foil polyimide construction. The 200 °C continuous limit and the watt density ceiling (to about 7.75 W/cm² with heat sinking) are properties of the polyimide film and the adhesive system, and are published consistently across the industry.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.

Build the Drawing

The panel above checks whether a size and a wattage can be built. This is the drawing itself: set the outline, route the heating track, place the lead wires, terminals, connector and temperature sensor, working in polyimide film, and turn the model to look at it. When it is right, export the 2D drawing as a PDF or a DXF and send it with your enquiry — a drawing is what a quotation for etched foil polyimide heaters is actually written from.

HEATING FILM DRAWING
Polyimide (PI / Kapton) Film Heater

Draw the outline, route the heating track, place the lead exits, terminals and sensor, dimension it, then export a PDF or a DXF and send it with your enquiry. Nothing here is a stock part and nothing you draw commits you to anything.

CMD

Want to compare constructions before you draw? Open the full builder, where every film family is selectable in one place.

Our facility

The numbers come off our own machines

Every unit is measured for resistance, held at its dielectric test voltage for a minute, and measured again for insulation resistance. Sample units from each lot are run under power and imaged. That is why the values on this page are quotable rather than indicative.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (UL 499 / IEC 60335 / RoHS)

ParameterSpecificationLimit / note
ConstructionPhoto-etched copper or Inconel foil circuit laminated between polyimide films with a high temperature acrylic or FEP adhesiveDecided at quotation from the outline and the wattage
Insulation systemPolyimide film, 0.05 mm or 0.125 mm per faceThis is what sets the temperature limit, not the element
Total thickness0.2 mmNominal, before adhesive; add 0.2 mm for PSA backing
Minimum size10 x 10 mmBelow this the element cannot be routed with a safe edge margin
Maximum size, one piece300 x 500 mm (one piece)Larger areas are supplied as tiled zones with separate circuits
Dimensional toleranceu00b10.5 mm on dimensions up to 200 mmOn the die-cut outline; hole positions are held tighter
Supply voltage5 V DC to 240 V AC, wound to orderWound to the ordered voltage u2014 it is not a switchable range
Resistance toleranceu00b110% standard, u00b15% on requestMeasured at 20 u00b0C; hot resistance differs with the element alloy
Watt density, free air0.8 W/cmu00b2 typical, 1.3 W/cmu00b2 maximumNothing conducting heat away u2014 the honest figure for an unbonded heater
Watt density, bonded to heat sink7.5 W/cmu00b2 maximumOnly valid with full-area contact to metal; specifying at this figure and running in free air destroys the heater
Continuous working temperature-200 u00b0C to +200 u00b0C continuous (+220 u00b0C short term)Of the heater itself, measured at the element, not the ambient
Dielectric strength1500 V AC, 1 minute (2500 V AC on the 0.125 mm film build)One minute, element to any exposed surface, no breakdown
Insulation resistancegreater than 100 Mu03a9At 500 V DC, measured after the dielectric test
Lead wirePTFE or silicone insulated 24 AWG to 20 AWG, or an FFC tail etched as part of the circuitLength, gauge and termination to your drawing
AttachmentFree, 3M PSA backing, or bonded with a two-part thermally conductive adhesiveAdhesive-backed heaters need continuous contact pressure while curing
Sensor and control optionsNTC 10K B3950, PT100/PT1000, K-type thermocouple, KSD9700 bimetal thermostat, thermal cutoffFitted under the same insulation and tested as one assembly
Certifications availableUL 499 construction, IEC/EN 60335, UL 94 V-0, RoHS, REACH, CE, ISO 13485 QMSConstructions are built to these; the certificate covers the construction, not every outline
Uniformityu00b11 u00b0C achievable over the heated area with a profiled circuitAchieved by trace geometry, and it is designed per outline
Circuit toleranceTrace width held to u00b10.05 mmWhich is what makes the resistance repeatable from lot to lot

Video: 110-120 V AC Etched Foil Polyimide Heaters

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

What watt density can etched foil polyimide heaters run at?

0.8 W/cm² with nothing conducting the heat away, and 7.5 W/cm² bonded over its whole area to metal. The two figures describe two different installations, not a range to choose from: a heater specified at 7.5 W/cm² and then run in free air reaches its insulation limit within minutes.

What is the maximum temperature of etched foil polyimide heaters?

200 °C continuous, measured at the element. The limit belongs to polyimide film and not to the element alloy, so it is not a figure that can be extended by derating the power.

Does this heater need a thermostat?

Yes. It has no mechanism for limiting its own temperature — with the load removed or the control loop failed it keeps producing the same power — so the design needs a controller with a sensor to hold the set point and, separately, a bimetal thermostat or a one-shot thermal cutoff in series with the element as protection.

Is there a part number I can order?

No — these are made to your drawing, so a part number would describe something that was never built. A quotation needs the outline, the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. The table on this page is what the factory can hold, not a stock list.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.