Skip to content
PET Film Heaters · IEC 60335 / UL 94 V-0 / RoHS

Printed Silver and Etched Copper PET Heaters for 80-120 °C

Which insulation systems hold 80 °C to 120 °C continuously, what this construction is rated to, and the control and cut-out that hold the surface there.

Printed Silver and Etched Copper PET Heaters are rated 120 °C continuous, a limit set by the PET polyester film, which covers 80 °C to 120 °C. Battery operating windows, incubators, fluid warming and display heating. The upper limit of PET film, and the band where a low-cost printed heater stops being a candidate.

Working band
80 °C to 120 °C
Continuous limit, this construction
120 °C
Set by
PET polyester film
Watt density
0.2 W/cm² free air, 1 W/cm² bonded
Total thickness
0.25 mm
Maximum outline, one piece
400 x 1000 mm

The band is the temperature the heated surface has to hold, not the temperature the element reaches. The element always runs hotter, by an amount the watt density and the thermal path decide, so the cut-out is set against the element and not against the load.

Printed Silver and Etched Copper PET Heaters — the construction this guide is about

Working temperature page for printed silver and etched copper pet heaters at 80 °c to 120 °c. What survives this band, what stops just below it, why the boundary is where it is, and how the temperature is actually measured and held.

What the 80 °C to 120 °C Band Requires

Battery operating windows, incubators, fluid warming and display heating. The upper limit of PET film, and the band where a low-cost printed heater stops being a candidate.

Band80 °C to 120 °C
This construction, continuous120 °C
Limited byPET polyester film

This band reaches the ceiling of the construction. At 120 °C there is no headroom left, so the control has to hold the set point rather than approach it from above, and the limit device has to be set where it can act before the insulation does. A duty that spends its time at the top of the band is a duty that should be quoted against the next construction up.

Why the Boundary Is Where It Is

120 °C is where PET film stops. The polyester softens from about 130 °C and loses its dielectric strength as it softens, so the margin between working temperature and failure is thin — and a failure here is an electrical one, not a cosmetic one.

This is therefore the last band in which the cheapest thin heater is a candidate. Above it, the construction changes to silicone or polyimide, and the cost per square metre changes with it.

What a Printed Silver and Etched Copper PET Heaters Is

Where carbon ink cannot hold the resistance tolerance or the watt density, a silver ink or an etched copper circuit on the same PET film.

Carbon or silver ink screen printed onto PET polyester film, laminated and die cut. It is made on a roll, which makes it the cheapest heater per square metre by a wide margin at volume, and it stops at 120 °C because the film does. Silver ink and etched copper give a much lower sheet resistance than carbon, which is what makes a low-voltage element on a large area practical; the trade is cost and, under a DC bias in damp air, the risk of silver migration between adjacent tracks.

The heat leaves through the bonded face. Everything that is not in contact with the load radiates and convects from the back of the heater instead, which at these thicknesses is a poor path — so an air gap under part of the outline is not a small loss of efficiency, it is a hot spot at that spot.

Elementscreen-printed carbon or silver ink
Insulation systemPET polyester film
Total thickness0.25 mm
Maximum size, one piece400 x 1000 mm
Continuous working temperature120 °C

The continuous limit of 120 °C is set by PET polyester film. The element alloy would run far hotter; it is never the element that decides.

Which Temperature Is Being Held

Three temperatures matter and they are not the same number: the element temperature, the temperature of the surface being heated, and the ambient. A heater rated for a continuous working temperature is rated at the element — the hottest point in the assembly, and the one nothing on the outside is measuring.

The gap between element and surface is the thermal path. Bonded to metal it may be a few degrees; across an air gap, a void in the adhesive or a dry clamped joint it can be tens of degrees, and every one of them appears at the element rather than at the load.

Which is why sensor position is a drawing item. A sensor laminated into the heater protects the heater; a sensor on the load controls the load. Assemblies that have to do both carry two: a control sensor where the process is, and a limit device against the element.

Watt Density: the Two Figures

Watt density, not wattage, is what the construction is limited by. 0.2 W/cm² unbonded and 1 W/cm² bonded to metal are the limits for this build — so if the wattage is fixed by the duty, the area is what has to move.

Where the required power will not fit into the available area at the free-air figure, the answer is a better thermal path rather than a thinner margin: bond the whole face down, or add a spreader plate. On 150 cm² the difference is roughly 3 W against 15 W, which is usually the whole argument.

Control and Protection

This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.

The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.

PET softens at about 130 °C and loses its dielectric strength as it does, so the cutoff temperature has to sit under that with margin. This is a construction that cannot be allowed to dry out and overshoot.

Sensors can be built into the part: NTC thermistor, PT100 or PT1000 RTD, or a K-type thermocouple, fitted under the same insulation and tested with the heater as one assembly. A sensor laminated into the heater reads the heater; a sensor on the load reads the load. Both are legitimate, and the drawing has to say which is wanted.

How This Construction Fails

  • Run at the bonded watt density in free air. The insulation reaches its limit within minutes and the element burns through where the local density is highest. Specify at 1 W/cm² only where the heater is genuinely bonded to metal over its whole area; unbonded, the figure is 0.2 W/cm².
  • Voids under the bond. Air trapped during application, a contaminated surface or an adhesive that never reached full cure all produce the same result: a patch with no thermal path, running far above the rest of the heater, which is where the failure starts.
  • Loss of the control loop. An open-circuit sensor, a welded relay contact or a controller in manual leaves the element at full power with nothing watching it — the case the series thermal cutoff exists for, and the reason it must not be omitted to save a part.
  • Overshoot into the film. PET softens from about 130 °C and its dielectric strength goes with it, so a fault that a silicone heater shrugs off destroys a PET element.
  • Silver migration. A printed silver circuit under a DC bias, in humidity, grows dendrites between adjacent tracks; carbon does not, which is one reason carbon is still used where the geometry allows it.

Where This Construction Is the Wrong Answer

  • Do not plan on running above 120 °C. That ceiling belongs to the insulation system, not to the element alloy, and it is not a figure that derating extends — past it the insulation degrades and the dielectric strength goes with it.
  • Do not use PET film for process heat. At 120 °C it is at its ceiling, and the constructions that go above it — silicone, polyimide, thick film — are different parts, not the same part with a different rating.

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • An outline drawing, or a sketch with dimensions: overall size, holes, cut-outs, radii and the lead exit position.
  • The supply voltage, and whether it is AC or DC. The element is wound for one voltage; it is not a switchable range.
  • The power required, or — better — the temperature to be reached and the mass or flow it has to be reached in. Given the second, the wattage can be calculated instead of guessed.
  • What the heater is attached to, and how. This is what decides which watt density figure applies, and it is the question a quotation cannot proceed without.
  • The ambient, and the lowest temperature the assembly must start from. A heater sized for a 20 °C start is undersized for a -30 °C one.
  • Duty cycle: continuous, intermittent, or a warm-up to a deadline. Time to temperature is a specification, not a by-product.
  • Sensor and protection: which sensor, where it goes, and which limit device is fitted in series with the element.
  • The certification the end product is built to, named on the enquiry rather than after approval.
  • Quantity and target price, because the construction that is right for fifty pieces is often not the one that is right for fifty thousand.
  • Whether adhesive backing is wanted, and what surface it goes onto — a low-energy plastic needs a different adhesive from bare aluminium.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

Printed Silver and Etched Copper PET Heaters — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
ConstructionSilver ink or etched copper circuit on PET film, laminatedDecided at quotation from the outline and the wattage
Insulation systemPET polyester film, 0.05 mm to 0.125 mm per faceThis is what sets the temperature limit, not the element
Total thickness0.25 mmNominal, before adhesive; add 0.2 mm for PSA backing
Minimum size20 x 20 mmBelow this the element cannot be routed with a safe edge margin
Maximum size, one piece400 x 1000 mmLarger areas are supplied as tiled zones with separate circuits
Dimensional toleranceu00b11 mm on the die-cut outlineOn the die-cut outline; hole positions are held tighter
Supply voltage12 V, 24 V, 48 V, 110 V, 220 VWound to the ordered voltage u2014 it is not a switchable range
Resistance toleranceu00b110% standard, u00b15% on requestMeasured at 20 u00b0C; hot resistance differs with the element alloy
Watt density, free air0.2 W/cmu00b2 typicalNothing conducting heat away u2014 the honest figure for an unbonded heater
Watt density, bonded to heat sink1.0 W/cmu00b2 maximumOnly valid with full-area contact to metal; specifying at this figure and running in free air destroys the heater
Continuous working temperature-40 u00b0C to +120 u00b0C continuousOf the heater itself, measured at the element, not the ambient
Dielectric strength1500 V AC, 1 minuteOne minute, element to any exposed surface, no breakdown
Insulation resistancegreater than 100 Mu03a9At 500 V DC, measured after the dielectric test
Lead wireCrimped or soldered leads, or a printed silver bus bar with a bonded tailLength, gauge and termination to your drawing
AttachmentPSA backing standard; laminated into the end product at high volumeAdhesive-backed heaters need continuous contact pressure while curing
Sensor and control optionsNTC 10K B3950 bonded to the film, or a printed PTC ink trackFitted under the same insulation and tested as one assembly
Certifications availableIEC/EN 60335, UL 94 V-0, RoHS, REACH, CE, IATF 16949Constructions are built to these; the certificate covers the construction, not every outline
Resistance toleranceu00b15% achievable, against u00b115% for carbon inkThe reason to pay for silver or copper on a thin film heater

Capability figures are for screen-printed carbon or silver ink on PET polyester film. The +120 °C continuous limit is the film's, and it is a hard limit: PET softens and loses dielectric strength above roughly 130 °C, so this construction is only a candidate where the maximum credible temperature is bounded well below it.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.

Build the Drawing

The panel above checks whether a size and a wattage can be built. This is the drawing itself: set the outline, route the heating track, place the lead wires, terminals, connector and temperature sensor, working in PET / PTC film, and turn the model to look at it. When it is right, export the 2D drawing as a PDF or a DXF and send it with your enquiry — a drawing is what a quotation for printed silver and etched copper pet heaters is actually written from.

HEATING FILM DRAWING
PET / PTC Film Heater

Draw the outline, route the heating track, place the lead exits, terminals and sensor, dimension it, then export a PDF or a DXF and send it with your enquiry. Nothing here is a stock part and nothing you draw commits you to anything.

CMD

Want to compare constructions before you draw? Open the full builder, where every film family is selectable in one place.

Our facility

The numbers come off our own machines

Every unit is measured for resistance, held at its dielectric test voltage for a minute, and measured again for insulation resistance. Sample units from each lot are run under power and imaged. That is why the values on this page are quotable rather than indicative.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (IEC 60335 / UL 94 V-0 / RoHS)

ParameterSpecificationLimit / note
ConstructionSilver ink or etched copper circuit on PET film, laminatedDecided at quotation from the outline and the wattage
Insulation systemPET polyester film, 0.05 mm to 0.125 mm per faceThis is what sets the temperature limit, not the element
Total thickness0.25 mmNominal, before adhesive; add 0.2 mm for PSA backing
Minimum size20 x 20 mmBelow this the element cannot be routed with a safe edge margin
Maximum size, one piece400 x 1000 mmLarger areas are supplied as tiled zones with separate circuits
Dimensional toleranceu00b11 mm on the die-cut outlineOn the die-cut outline; hole positions are held tighter
Supply voltage12 V, 24 V, 48 V, 110 V, 220 VWound to the ordered voltage u2014 it is not a switchable range
Resistance toleranceu00b110% standard, u00b15% on requestMeasured at 20 u00b0C; hot resistance differs with the element alloy
Watt density, free air0.2 W/cmu00b2 typicalNothing conducting heat away u2014 the honest figure for an unbonded heater
Watt density, bonded to heat sink1.0 W/cmu00b2 maximumOnly valid with full-area contact to metal; specifying at this figure and running in free air destroys the heater
Continuous working temperature-40 u00b0C to +120 u00b0C continuousOf the heater itself, measured at the element, not the ambient
Dielectric strength1500 V AC, 1 minuteOne minute, element to any exposed surface, no breakdown
Insulation resistancegreater than 100 Mu03a9At 500 V DC, measured after the dielectric test
Lead wireCrimped or soldered leads, or a printed silver bus bar with a bonded tailLength, gauge and termination to your drawing
AttachmentPSA backing standard; laminated into the end product at high volumeAdhesive-backed heaters need continuous contact pressure while curing
Sensor and control optionsNTC 10K B3950 bonded to the film, or a printed PTC ink trackFitted under the same insulation and tested as one assembly
Certifications availableIEC/EN 60335, UL 94 V-0, RoHS, REACH, CE, IATF 16949Constructions are built to these; the certificate covers the construction, not every outline
Resistance toleranceu00b15% achievable, against u00b115% for carbon inkThe reason to pay for silver or copper on a thin film heater

Video: Printed Silver and Etched Copper PET Heaters for 80-120 °C

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

What is the maximum temperature of printed silver and etched copper pet heaters?

120 °C continuous, measured at the element. The limit belongs to PET polyester film and not to the element alloy, so it is not a figure that can be extended by derating the power.

Does this heater need a thermostat?

Yes. It has no mechanism for limiting its own temperature — with the load removed or the control loop failed it keeps producing the same power — so the design needs a controller with a sensor to hold the set point and, separately, a bimetal thermostat or a one-shot thermal cutoff in series with the element as protection.

Is there a part number I can order?

No — these are made to your drawing, so a part number would describe something that was never built. A quotation needs the outline, the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. The table on this page is what the factory can hold, not a stock list.

How large can one piece be?

400 x 1000 mm in a single piece. Larger areas are supplied as tiled zones with separate circuits, which is usually better engineering anyway: separate zones can be controlled separately, and a large single circuit has to carry the whole current at one lead exit.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.