Skip to content
PET Film Heaters · IEC 60335 / UL 94 V-0 / RoHS

PET Polyester Film PET Film Heaters with PSA Backing

What this insulation holds continuously, how thick the finished part is, the watt density it takes in free air and bonded, and where it stops being the right choice.

PET Polyester Film — -40 °C to +120 °C continuous. The low-cost thin-film substrate, printed rather than etched. Roll-to-roll production makes it the cheapest heater per square metre by a wide margin at volume. In this construction it carries 0.1 W/cm² in free air and 0.5 W/cm² bonded over its whole area to metal.

Insulation system
PET Polyester Film
Temperature range
-40 °C to +120 °C continuous
Where it stops
PET softens above about 130 °C and loses its dielectric strength there. It is not a candidate for anything that can dry out and overshoot.
Continuous temperature limit
120 °C continuous
Watt density
0.1 W/cm² free air, 0.5 W/cm² bonded
Total thickness
0.3 mm

The temperature ceiling belongs to the insulation, not to the element: the resistance alloy would run far hotter, and it is the insulation around it that fails first. Figures are for the insulation system as built here; a part is quoted against the drawing, not against this table.

PET Film Heaters with PSA Backing — the construction this guide is about

Insulation system page for pet film heaters with psa backing built in PET Polyester Film. The ceiling (-40 °C to +120 °C continuous), the mechanical behaviour, the dielectric strength, the failure route out of the material, and the constructions to move to when the duty goes past it.

PET Polyester Film as an Insulation System

The low-cost thin-film substrate, printed rather than etched. Roll-to-roll production makes it the cheapest heater per square metre by a wide margin at volume.

Working range-40 °C to +120 °C continuous
Total thickness in this construction0.3 mm
Dielectric withstand1500 V AC, 1 minute
Insulation resistancegreater than 100 Mu03a9
Maximum size, one piece400 x 800 mm

A flexible insulation has to do three jobs at once: hold off the supply voltage, survive the element temperature, and bend without cracking. Thickness trades against all three — a thinner build responds faster and conforms better, and has less material between the element and whatever the heater is touching.

The Temperature Ceiling, and What Sets It

Working range: -40 °C to +120 °C continuous. The ceiling belongs to the insulation. Nichrome will run red; pet polyester film will not, and it is the material around the element that decides what the part is rated at.

This construction is rated 120 °C continuous. That is a continuous figure at the element, not an ambient and not a surface temperature measured somewhere convenient — and it is not a figure that derating extends downwards from something higher. Past the ceiling the insulation degrades, the dielectric strength falls with it, and the failure is electrical rather than thermal.

The boundaries across this catalogue are all material boundaries: PET stops at 120 °C, filled epoxy at 150 °C, silicone rubber and polyimide at 200 °C, and above that only fired and inorganic systems — thick film on stainless or alumina, and mica — are candidates at all.

What Attacks PET Polyester Film

PET softens above about 130 °C and loses its dielectric strength there. It is not a candidate for anything that can dry out and overshoot.

What a PET Film Heaters with PSA Backing Is

Standard printed film heaters supplied with adhesive and a liner, for bonding to plastic, glass or sheet metal in assembly.

Carbon or silver ink screen printed onto PET polyester film, laminated and die cut. It is made on a roll, which makes it the cheapest heater per square metre by a wide margin at volume, and it stops at 120 °C because the film does.

The heat leaves through the bonded face. Everything that is not in contact with the load radiates and convects from the back of the heater instead, which at these thicknesses is a poor path — so an air gap under part of the outline is not a small loss of efficiency, it is a hot spot at that spot.

Elementscreen-printed carbon or silver ink
Insulation systemPET polyester film
Total thickness0.3 mm
Maximum size, one piece400 x 800 mm
Continuous working temperature120 °C

The continuous limit of 120 °C is set by PET polyester film. The element alloy would run far hotter; it is never the element that decides.

Above Its Ceiling: What to Use Instead

Above 120 °C the film softens and its dielectric strength goes with it, so the answer is a different construction rather than a derated one: polyimide to 200 °C at a similar thickness and a much higher watt density, silicone rubber to 200 °C where the surface is curved or the part needs to be tough, and thick film where the duty is above 200 °C. Below 120 °C nothing beats PET on cost per square metre at volume, which is the whole reason it exists here.

What the Insulation Changes About the Heater

The insulation decides the thickness (0.3 mm here), and the thickness decides the response: less material between the element and the load means less to heat before anything useful happens, and less thermal resistance in the way of the heat that follows. It also decides what the heater will wrap around — this construction wraps a cylinder but will not take a compound curve.

Watt Density: the Two Figures

Watt density, not wattage, is what the construction is limited by. 0.1 W/cm² unbonded and 0.5 W/cm² bonded to metal are the limits for this build — so if the wattage is fixed by the duty, the area is what has to move.

Where the required power will not fit into the available area at the free-air figure, the answer is a better thermal path rather than a thinner margin: bond the whole face down, or add a spreader plate. On 150 cm² the difference is roughly 15 W against 75 W, which is usually the whole argument.

Control and Protection

This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.

The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.

PET softens at about 130 °C and loses its dielectric strength as it does, so the cutoff temperature has to sit under that with margin. This is a construction that cannot be allowed to dry out and overshoot.

Sensors can be built into the part: NTC thermistor, PT100 or PT1000 RTD, or a K-type thermocouple, fitted under the same insulation and tested with the heater as one assembly. A sensor laminated into the heater reads the heater; a sensor on the load reads the load. Both are legitimate, and the drawing has to say which is wanted.

T

h

How This Construction Fails

  • Run at the bonded watt density in free air. The insulation reaches its limit within minutes and the element burns through where the local density is highest. Specify at 0.5 W/cm² only where the heater is genuinely bonded to metal over its whole area; unbonded, the figure is 0.1 W/cm².
  • Voids under the bond. Air trapped during application, a contaminated surface or an adhesive that never reached full cure all produce the same result: a patch with no thermal path, running far above the rest of the heater, which is where the failure starts.
  • Loss of the control loop. An open-circuit sensor, a welded relay contact or a controller in manual leaves the element at full power with nothing watching it — the case the series thermal cutoff exists for, and the reason it must not be omitted to save a part.
  • Overshoot into the film. PET softens from about 130 °C and its dielectric strength goes with it, so a fault that a silicone heater shrugs off destroys a PET element.
  • Silver migration. A printed silver circuit under a DC bias, in humidity, grows dendrites between adjacent tracks; carbon does not, which is one reason carbon is still used where the geometry allows it.

Leads and Terminations

Lead wire as supplied: Crimped or soldered leads, or a printed silver bus bar with a bonded tail. Length, gauge, exit position and termination are drawing items — the exit position in particular, because it decides where the heater can be routed and it cannot be changed after the tool is cut.

The lead exit is a thermal discontinuity as well as an electrical one. The joint between a fine element and a stranded lead is the hottest point of many heaters, so it is kept out of the highest watt density zone, strain relieved, and — where the exit sits in a hot area — insulated in PTFE rather than in silicone.

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • An outline drawing, or a sketch with dimensions: overall size, holes, cut-outs, radii and the lead exit position.
  • The supply voltage, and whether it is AC or DC. The element is wound for one voltage; it is not a switchable range.
  • The power required, or — better — the temperature to be reached and the mass or flow it has to be reached in. Given the second, the wattage can be calculated instead of guessed.
  • What the heater is attached to, and how. This is what decides which watt density figure applies, and it is the question a quotation cannot proceed without.
  • The ambient, and the lowest temperature the assembly must start from. A heater sized for a 20 °C start is undersized for a -30 °C one.
  • Duty cycle: continuous, intermittent, or a warm-up to a deadline. Time to temperature is a specification, not a by-product.
  • Sensor and protection: which sensor, where it goes, and which limit device is fitted in series with the element.
  • The certification the end product is built to, named on the enquiry rather than after approval.
  • Quantity and target price, because the construction that is right for fifty pieces is often not the one that is right for fifty thousand.
  • Whether adhesive backing is wanted, and what surface it goes onto — a low-energy plastic needs a different adhesive from bare aluminium.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

PET Film Heaters with PSA Backing — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
ConstructionCarbon or silver ink on PET with 3M PSA backingDecided at quotation from the outline and the wattage
Insulation systemPET polyester film, 0.05 mm to 0.125 mm per faceThis is what sets the temperature limit, not the element
Total thickness0.3 mmNominal, before adhesive; add 0.2 mm for PSA backing
Minimum size20 x 20 mmBelow this the element cannot be routed with a safe edge margin
Maximum size, one piece400 x 800 mmLarger areas are supplied as tiled zones with separate circuits
Dimensional toleranceu00b11 mm on the die-cut outlineOn the die-cut outline; hole positions are held tighter
Supply voltage12 V, 24 V, 48 V, 110 V, 220 VWound to the ordered voltage u2014 it is not a switchable range
Resistance toleranceu00b110% standard, u00b15% on requestMeasured at 20 u00b0C; hot resistance differs with the element alloy
Watt density, free air0.1 W/cmu00b2 typicalNothing conducting heat away u2014 the honest figure for an unbonded heater
Watt density, bonded to heat sink0.5 W/cmu00b2 maximumOnly valid with full-area contact to metal; specifying at this figure and running in free air destroys the heater
Continuous working temperature-40 u00b0C to +120 u00b0C continuousOf the heater itself, measured at the element, not the ambient
Dielectric strength1500 V AC, 1 minuteOne minute, element to any exposed surface, no breakdown
Insulation resistancegreater than 100 Mu03a9At 500 V DC, measured after the dielectric test
Lead wireCrimped or soldered leads, or a printed silver bus bar with a bonded tailLength, gauge and termination to your drawing
AttachmentPSA backing standard; laminated into the end product at high volumeAdhesive-backed heaters need continuous contact pressure while curing
Sensor and control optionsNTC 10K B3950 bonded to the film, or a printed PTC ink trackFitted under the same insulation and tested as one assembly
Certifications availableIEC/EN 60335, UL 94 V-0, RoHS, REACH, CE, IATF 16949Constructions are built to these; the certificate covers the construction, not every outline

Capability figures are for screen-printed carbon or silver ink on PET polyester film. The +120 °C continuous limit is the film's, and it is a hard limit: PET softens and loses dielectric strength above roughly 130 °C, so this construction is only a candidate where the maximum credible temperature is bounded well below it.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.

Build the Drawing

The panel above checks whether a size and a wattage can be built. This is the drawing itself: set the outline, route the heating track, place the lead wires, terminals, connector and temperature sensor, working in PET / PTC film, and turn the model to look at it. When it is right, export the 2D drawing as a PDF or a DXF and send it with your enquiry — a drawing is what a quotation for pet film heaters with psa backing is actually written from.

HEATING FILM DRAWING
PET / PTC Film Heater

Draw the outline, route the heating track, place the lead exits, terminals and sensor, dimension it, then export a PDF or a DXF and send it with your enquiry. Nothing here is a stock part and nothing you draw commits you to anything.

CMD

Want to compare constructions before you draw? Open the full builder, where every film family is selectable in one place.

Our facility

Held in production, not just on paper

The limits above are the ones our own lamination press, die and test lines actually hold, and every unit is tested rather than a sample. A figure is only worth quoting if it survives the process that produces it.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (IEC 60335 / UL 94 V-0 / RoHS)

ParameterSpecificationLimit / note
ConstructionCarbon or silver ink on PET with 3M PSA backingDecided at quotation from the outline and the wattage
Insulation systemPET polyester film, 0.05 mm to 0.125 mm per faceThis is what sets the temperature limit, not the element
Total thickness0.3 mmNominal, before adhesive; add 0.2 mm for PSA backing
Minimum size20 x 20 mmBelow this the element cannot be routed with a safe edge margin
Maximum size, one piece400 x 800 mmLarger areas are supplied as tiled zones with separate circuits
Dimensional toleranceu00b11 mm on the die-cut outlineOn the die-cut outline; hole positions are held tighter
Supply voltage12 V, 24 V, 48 V, 110 V, 220 VWound to the ordered voltage u2014 it is not a switchable range
Resistance toleranceu00b110% standard, u00b15% on requestMeasured at 20 u00b0C; hot resistance differs with the element alloy
Watt density, free air0.1 W/cmu00b2 typicalNothing conducting heat away u2014 the honest figure for an unbonded heater
Watt density, bonded to heat sink0.5 W/cmu00b2 maximumOnly valid with full-area contact to metal; specifying at this figure and running in free air destroys the heater
Continuous working temperature-40 u00b0C to +120 u00b0C continuousOf the heater itself, measured at the element, not the ambient
Dielectric strength1500 V AC, 1 minuteOne minute, element to any exposed surface, no breakdown
Insulation resistancegreater than 100 Mu03a9At 500 V DC, measured after the dielectric test
Lead wireCrimped or soldered leads, or a printed silver bus bar with a bonded tailLength, gauge and termination to your drawing
AttachmentPSA backing standard; laminated into the end product at high volumeAdhesive-backed heaters need continuous contact pressure while curing
Sensor and control optionsNTC 10K B3950 bonded to the film, or a printed PTC ink trackFitted under the same insulation and tested as one assembly
Certifications availableIEC/EN 60335, UL 94 V-0, RoHS, REACH, CE, IATF 16949Constructions are built to these; the certificate covers the construction, not every outline

Video: PET Polyester Film PET Film Heaters with PSA Backing

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

What are the weaknesses of PET Polyester Film?

PET softens above about 130 °C and loses its dielectric strength there. It is not a candidate for anything that can dry out and overshoot.

What should I use instead of PET Polyester Film above its limit?

Above 120 °C the film softens and its dielectric strength goes with it, so the answer is a different construction rather than a derated one: polyimide to 200 °C at a similar thickness and a much higher watt density, silicone rubber to 200 °C where the surface is curved or the part needs to be tough, and thick film where the duty is above 200 °C. Below 120 °C nothing beats PET on cost per square metre at volume, which is the whole reason it exists here.

What watt density can pet film heaters with psa backing run at?

0.1 W/cm² with nothing conducting the heat away, and 0.5 W/cm² bonded over its whole area to metal. The two figures describe two different installations, not a range to choose from: a heater specified at 0.5 W/cm² and then run in free air reaches its insulation limit within minutes.

What is the maximum temperature of pet film heaters with psa backing?

120 °C continuous, measured at the element. The limit belongs to PET polyester film and not to the element alloy, so it is not a figure that can be extended by derating the power.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.