Aramid Paper (Nomex type): A thin, tough, low-cost flexible insulation used where polyimide is unnecessary and silicone is too thick, mostly in transformer and appliance heating. Its working range is To +180 °C continuous, and that range is the property everything else on the part is designed around, because the element will always outlast the insulation around it.
Aramid Paper (Nomex type) as an Insulation System
A thin, tough, low-cost flexible insulation used where polyimide is unnecessary and silicone is too thick, mostly in transformer and appliance heating.
| Working range | To +180 °C continuous |
|---|---|
| Total thickness in this construction | 2.0 mm |
| Dielectric withstand | 2500 V AC, 1 minute |
| Insulation resistance | greater than 100 Mu03a9 |
| Maximum size, one piece | 2500 x 600 mm |
A flexible insulation has to do three jobs at once: hold off the supply voltage, survive the element temperature, and bend without cracking. Thickness trades against all three — a thinner build responds faster and conforms better, and has less material between the element and whatever the heater is touching.
The Temperature Ceiling, and What Sets It
Working range: To +180 °C continuous. The ceiling belongs to the insulation. Nichrome will run red; aramid paper (nomex type) will not, and it is the material around the element that decides what the part is rated at.
This construction is rated 200 °C continuous. That is a continuous figure at the element, not an ambient and not a surface temperature measured somewhere convenient — and it is not a figure that derating extends downwards from something higher. Past the ceiling the insulation degrades, the dielectric strength falls with it, and the failure is electrical rather than thermal.
The boundaries across this catalogue are all material boundaries: PET stops at 120 °C, filled epoxy at 150 °C, silicone rubber and polyimide at 200 °C, and above that only fired and inorganic systems — thick film on stainless or alumina, and mica — are candidates at all.
What Attacks Aramid Paper (Nomex type)
Absorbs moisture, and its dielectric strength falls when it does.
Resistant is not sealed. The material shrugs off splash, ozone and humidity, and it is still permeable to water vapour over time; a heater that will be immersed or steam-cleaned needs a sealed edge, not just a resistant one.
What a Drum and IBC Silicone Heating Blankets Is
Wrap-around blankets for 20 L pails, 200 L drums and 1000 L IBC totes, for thawing and for holding viscous product pumpable.
Nichrome resistance wire, or an etched Inconel foil circuit, vulcanised between two sheets of fibreglass-reinforced silicone rubber. The construction is about 1.2 to 2 mm thick, conforms to a curved surface, and holds its dielectric strength from -50 °C up to 200 °C continuously. Wrapped around a pipe, a drum or an IBC, the heated face is the inside of the wrap, so the useful watt density is the bonded figure only while the wrap is strapped down over its whole area — a blanket that has lifted away from the wall is running in free air at the point where it lifted.
The heat leaves through the bonded face. Everything that is not in contact with the load radiates and convects from the back of the heater instead, which at these thicknesses is a poor path — so an air gap under part of the outline is not a small loss of efficiency, it is a hot spot at that spot.
| Element | nichrome wire or etched Inconel foil |
|---|---|
| Insulation system | fibreglass-reinforced silicone rubber |
| Total thickness | 2.0 mm |
| Maximum size, one piece | 2500 x 600 mm |
| Continuous working temperature | 200 °C |
The continuous limit of 200 °C is set by fibreglass-reinforced silicone rubber. The element alloy would run far hotter; it is never the element that decides.
Above Its Ceiling: What to Use Instead
Aramid paper is a 180 °C insulation used where polyimide is unnecessary and silicone is too thick. Above it, silicone rubber and polyimide both reach 200 °C; above 200 °C the polymers stop altogether and the construction changes to a fired or mica-insulated one. Its weakness is moisture — it absorbs it, and its dielectric strength falls when it does — so a damp installation is a reason to move to silicone even well below the temperature limit.
What the Insulation Changes About the Heater
The insulation decides the thickness (2.0 mm here), and the thickness decides the response: less material between the element and the load means less to heat before anything useful happens, and less thermal resistance in the way of the heat that follows. It also decides what the heater will wrap around — this construction takes a compound curve, not just a cylinder.
Watt Density: the Two Figures
Watt density, not wattage, is what the construction is limited by. 0.4 W/cm² unbonded and 2 W/cm² bonded to metal are the limits for this build — so if the wattage is fixed by the duty, the area is what has to move.
Where the required power will not fit into the available area at the free-air figure, the answer is a better thermal path rather than a thinner margin: bond the whole face down, or add a spreader plate. On 150 cm² the difference is roughly 6 W against 3 W, which is usually the whole argument.
Control and Protection
This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.
The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.
Sensors can be built into the part: NTC thermistor, PT100 or PT1000 RTD, or a K-type thermocouple, fitted under the same insulation and tested with the heater as one assembly. A sensor laminated into the heater reads the heater; a sensor on the load reads the load. Both are legitimate, and the drawing has to say which is wanted.
T
h
Where This Construction Is the Wrong Answer
- Do not plan on running above 200 °C. That ceiling belongs to the insulation system, not to the element alloy, and it is not a figure that derating extends — past it the insulation degrades and the dielectric strength goes with it.
- Do not treat silicone as a moisture barrier. It is permeable to water vapour and is attacked by concentrated acids and some solvents; where the heater is immersed or splashed continuously, the sealing is a design item and not a property of the material.
Leads and Terminations
Lead wire as supplied: Silicone-insulated stranded copper, 22 AWG to 16 AWG, PTFE where the exit is hot. Length, gauge, exit position and termination are drawing items — the exit position in particular, because it decides where the heater can be routed and it cannot be changed after the tool is cut.
The lead exit is a thermal discontinuity as well as an electrical one. The joint between a fine element and a stranded lead is the hottest point of many heaters, so it is kept out of the highest watt density zone, strain relieved, and — where the exit sits in a hot area — insulated in PTFE rather than in silicone.
How to Specify One
This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:
- An outline drawing, or a sketch with dimensions: overall size, holes, cut-outs, radii and the lead exit position.
- The supply voltage, and whether it is AC or DC. The element is wound for one voltage; it is not a switchable range.
- The power required, or — better — the temperature to be reached and the mass or flow it has to be reached in. Given the second, the wattage can be calculated instead of guessed.
- What the heater is attached to, and how. This is what decides which watt density figure applies, and it is the question a quotation cannot proceed without.
- The ambient, and the lowest temperature the assembly must start from. A heater sized for a 20 °C start is undersized for a -30 °C one.
- Duty cycle: continuous, intermittent, or a warm-up to a deadline. Time to temperature is a specification, not a by-product.
- Sensor and protection: which sensor, where it goes, and which limit device is fitted in series with the element.
- The certification the end product is built to, named on the enquiry rather than after approval.
- Quantity and target price, because the construction that is right for fifty pieces is often not the one that is right for fifty thousand.
- Whether adhesive backing is wanted, and what surface it goes onto — a low-energy plastic needs a different adhesive from bare aluminium.
Lead time: Samples 7-10 days from approved drawing; production 15-20 days.
Drum and IBC Silicone Heating Blankets — Capability Table
These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.
| Parameter | Specification | Limit / note |
|---|---|---|
| Construction | Nichrome resistance wire wound on a fibreglass carrier, or etched Inconel foil, vulcanised between two sheets of fibreglass-reinforced silicone rubber | Decided at quotation from the outline and the wattage |
| Insulation system | Fibreglass-reinforced silicone rubber, both faces | This is what sets the temperature limit, not the element |
| Total thickness | 2.0 mm | Nominal, before adhesive; add 0.2 mm for PSA backing |
| Minimum size | 25 x 25 mm | Below this the element cannot be routed with a safe edge margin |
| Maximum size, one piece | 2500 x 600 mm | Larger areas are supplied as tiled zones with separate circuits |
| Dimensional tolerance | u00b11.5 mm on dimensions up to 300 mm, u00b10.5%% above | On the die-cut outline; hole positions are held tighter |
| Supply voltage | 5 V DC to 240 V AC, wound to order | Wound to the ordered voltage u2014 it is not a switchable range |
| Resistance tolerance | u00b110% standard, u00b15% on request | Measured at 20 u00b0C; hot resistance differs with the element alloy |
| Watt density, free air | 0.4 W/cmu00b2 typical, 0.6 W/cmu00b2 maximum | Nothing conducting heat away u2014 the honest figure for an unbonded heater |
| Watt density, bonded to heat sink | 2.0 W/cmu00b2 maximum | Only valid with full-area contact to metal; specifying at this figure and running in free air destroys the heater |
| Continuous working temperature | -50 u00b0C to +200 u00b0C continuous (+240 u00b0C intermittent) | Of the heater itself, measured at the element, not the ambient |
| Dielectric strength | 2500 V AC, 1 minute | One minute, element to any exposed surface, no breakdown |
| Insulation resistance | greater than 100 Mu03a9 | At 500 V DC, measured after the dielectric test |
| Lead wire | Silicone-insulated stranded copper, 22 AWG to 16 AWG, PTFE where the exit is hot | Length, gauge and termination to your drawing |
| Attachment | Free, 3M 468MP or 9077 PSA backing, vulcanised to the part, or mechanically clamped | Adhesive-backed heaters need continuous contact pressure while curing |
| Sensor and control options | NTC 10K B3950, PT100/PT1000, K-type thermocouple, KSD9700 bimetal thermostat, thermal cutoff | Fitted under the same insulation and tested as one assembly |
| Certifications available | UL 499 construction, IEC/EN 60335, UL 94 V-0 materials, RoHS, REACH, CE | Constructions are built to these; the certificate covers the construction, not every outline |
| Standard sizes | 20 L pail, 200 L steel or plastic drum, 1000 L IBC | Non-standard vessels are quoted from the circumference and height |
| Control | Integral capillary thermostat 0-90 u00b0C, or external digital controller | A blanket on an empty drum reaches its own limit within minutes u2014 a control is not optional |
Capability figures are this factory's process limits for the construction described. Watt density limits follow the published maxima for fibreglass-reinforced silicone rubber heaters (to about 12 W/cm² bonded to a heat sink, far less in free air); continuous temperature limits are those of the silicone insulation system, not of the element alloy.