Skip to content
Silicone Rubber Heaters · UL 499 / IEC 60335 / RoHS

Aramid Paper (Nomex type) Drum and IBC Silicone Heating Blankets

What this insulation holds continuously, how thick the finished part is, the watt density it takes in free air and bonded, and where it stops being the right choice.

Aramid Paper (Nomex type) — To +180 °C continuous. A thin, tough, low-cost flexible insulation used where polyimide is unnecessary and silicone is too thick, mostly in transformer and appliance heating. In this construction it carries 0.4 W/cm² in free air and 2 W/cm² bonded over its whole area to metal.

Insulation system
Aramid Paper (Nomex type)
Temperature range
To +180 °C continuous
Where it stops
Absorbs moisture, and its dielectric strength falls when it does.
Continuous temperature limit
200 °C continuous
Watt density
0.4 W/cm² free air, 2 W/cm² bonded
Total thickness
2.0 mm

The temperature ceiling belongs to the insulation, not to the element: the resistance alloy would run far hotter, and it is the insulation around it that fails first. Figures are for the insulation system as built here; a part is quoted against the drawing, not against this table.

Drum and IBC Silicone Heating Blankets — the construction this guide is about

Aramid Paper (Nomex type): A thin, tough, low-cost flexible insulation used where polyimide is unnecessary and silicone is too thick, mostly in transformer and appliance heating. Its working range is To +180 °C continuous, and that range is the property everything else on the part is designed around, because the element will always outlast the insulation around it.

Aramid Paper (Nomex type) as an Insulation System

A thin, tough, low-cost flexible insulation used where polyimide is unnecessary and silicone is too thick, mostly in transformer and appliance heating.

Working rangeTo +180 °C continuous
Total thickness in this construction2.0 mm
Dielectric withstand2500 V AC, 1 minute
Insulation resistancegreater than 100 Mu03a9
Maximum size, one piece2500 x 600 mm

A flexible insulation has to do three jobs at once: hold off the supply voltage, survive the element temperature, and bend without cracking. Thickness trades against all three — a thinner build responds faster and conforms better, and has less material between the element and whatever the heater is touching.

The Temperature Ceiling, and What Sets It

Working range: To +180 °C continuous. The ceiling belongs to the insulation. Nichrome will run red; aramid paper (nomex type) will not, and it is the material around the element that decides what the part is rated at.

This construction is rated 200 °C continuous. That is a continuous figure at the element, not an ambient and not a surface temperature measured somewhere convenient — and it is not a figure that derating extends downwards from something higher. Past the ceiling the insulation degrades, the dielectric strength falls with it, and the failure is electrical rather than thermal.

The boundaries across this catalogue are all material boundaries: PET stops at 120 °C, filled epoxy at 150 °C, silicone rubber and polyimide at 200 °C, and above that only fired and inorganic systems — thick film on stainless or alumina, and mica — are candidates at all.

What Attacks Aramid Paper (Nomex type)

Absorbs moisture, and its dielectric strength falls when it does.

Resistant is not sealed. The material shrugs off splash, ozone and humidity, and it is still permeable to water vapour over time; a heater that will be immersed or steam-cleaned needs a sealed edge, not just a resistant one.

What a Drum and IBC Silicone Heating Blankets Is

Wrap-around blankets for 20 L pails, 200 L drums and 1000 L IBC totes, for thawing and for holding viscous product pumpable.

Nichrome resistance wire, or an etched Inconel foil circuit, vulcanised between two sheets of fibreglass-reinforced silicone rubber. The construction is about 1.2 to 2 mm thick, conforms to a curved surface, and holds its dielectric strength from -50 °C up to 200 °C continuously. Wrapped around a pipe, a drum or an IBC, the heated face is the inside of the wrap, so the useful watt density is the bonded figure only while the wrap is strapped down over its whole area — a blanket that has lifted away from the wall is running in free air at the point where it lifted.

The heat leaves through the bonded face. Everything that is not in contact with the load radiates and convects from the back of the heater instead, which at these thicknesses is a poor path — so an air gap under part of the outline is not a small loss of efficiency, it is a hot spot at that spot.

Elementnichrome wire or etched Inconel foil
Insulation systemfibreglass-reinforced silicone rubber
Total thickness2.0 mm
Maximum size, one piece2500 x 600 mm
Continuous working temperature200 °C

The continuous limit of 200 °C is set by fibreglass-reinforced silicone rubber. The element alloy would run far hotter; it is never the element that decides.

Above Its Ceiling: What to Use Instead

Aramid paper is a 180 °C insulation used where polyimide is unnecessary and silicone is too thick. Above it, silicone rubber and polyimide both reach 200 °C; above 200 °C the polymers stop altogether and the construction changes to a fired or mica-insulated one. Its weakness is moisture — it absorbs it, and its dielectric strength falls when it does — so a damp installation is a reason to move to silicone even well below the temperature limit.

What the Insulation Changes About the Heater

The insulation decides the thickness (2.0 mm here), and the thickness decides the response: less material between the element and the load means less to heat before anything useful happens, and less thermal resistance in the way of the heat that follows. It also decides what the heater will wrap around — this construction takes a compound curve, not just a cylinder.

Watt Density: the Two Figures

Watt density, not wattage, is what the construction is limited by. 0.4 W/cm² unbonded and 2 W/cm² bonded to metal are the limits for this build — so if the wattage is fixed by the duty, the area is what has to move.

Where the required power will not fit into the available area at the free-air figure, the answer is a better thermal path rather than a thinner margin: bond the whole face down, or add a spreader plate. On 150 cm² the difference is roughly 6 W against 3 W, which is usually the whole argument.

Control and Protection

This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.

The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.

Sensors can be built into the part: NTC thermistor, PT100 or PT1000 RTD, or a K-type thermocouple, fitted under the same insulation and tested with the heater as one assembly. A sensor laminated into the heater reads the heater; a sensor on the load reads the load. Both are legitimate, and the drawing has to say which is wanted.

T

h

Where This Construction Is the Wrong Answer

  • Do not plan on running above 200 °C. That ceiling belongs to the insulation system, not to the element alloy, and it is not a figure that derating extends — past it the insulation degrades and the dielectric strength goes with it.
  • Do not treat silicone as a moisture barrier. It is permeable to water vapour and is attacked by concentrated acids and some solvents; where the heater is immersed or splashed continuously, the sealing is a design item and not a property of the material.

Leads and Terminations

Lead wire as supplied: Silicone-insulated stranded copper, 22 AWG to 16 AWG, PTFE where the exit is hot. Length, gauge, exit position and termination are drawing items — the exit position in particular, because it decides where the heater can be routed and it cannot be changed after the tool is cut.

The lead exit is a thermal discontinuity as well as an electrical one. The joint between a fine element and a stranded lead is the hottest point of many heaters, so it is kept out of the highest watt density zone, strain relieved, and — where the exit sits in a hot area — insulated in PTFE rather than in silicone.

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • An outline drawing, or a sketch with dimensions: overall size, holes, cut-outs, radii and the lead exit position.
  • The supply voltage, and whether it is AC or DC. The element is wound for one voltage; it is not a switchable range.
  • The power required, or — better — the temperature to be reached and the mass or flow it has to be reached in. Given the second, the wattage can be calculated instead of guessed.
  • What the heater is attached to, and how. This is what decides which watt density figure applies, and it is the question a quotation cannot proceed without.
  • The ambient, and the lowest temperature the assembly must start from. A heater sized for a 20 °C start is undersized for a -30 °C one.
  • Duty cycle: continuous, intermittent, or a warm-up to a deadline. Time to temperature is a specification, not a by-product.
  • Sensor and protection: which sensor, where it goes, and which limit device is fitted in series with the element.
  • The certification the end product is built to, named on the enquiry rather than after approval.
  • Quantity and target price, because the construction that is right for fifty pieces is often not the one that is right for fifty thousand.
  • Whether adhesive backing is wanted, and what surface it goes onto — a low-energy plastic needs a different adhesive from bare aluminium.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

Drum and IBC Silicone Heating Blankets — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
ConstructionNichrome resistance wire wound on a fibreglass carrier, or etched Inconel foil, vulcanised between two sheets of fibreglass-reinforced silicone rubberDecided at quotation from the outline and the wattage
Insulation systemFibreglass-reinforced silicone rubber, both facesThis is what sets the temperature limit, not the element
Total thickness2.0 mmNominal, before adhesive; add 0.2 mm for PSA backing
Minimum size25 x 25 mmBelow this the element cannot be routed with a safe edge margin
Maximum size, one piece2500 x 600 mmLarger areas are supplied as tiled zones with separate circuits
Dimensional toleranceu00b11.5 mm on dimensions up to 300 mm, u00b10.5%% aboveOn the die-cut outline; hole positions are held tighter
Supply voltage5 V DC to 240 V AC, wound to orderWound to the ordered voltage u2014 it is not a switchable range
Resistance toleranceu00b110% standard, u00b15% on requestMeasured at 20 u00b0C; hot resistance differs with the element alloy
Watt density, free air0.4 W/cmu00b2 typical, 0.6 W/cmu00b2 maximumNothing conducting heat away u2014 the honest figure for an unbonded heater
Watt density, bonded to heat sink2.0 W/cmu00b2 maximumOnly valid with full-area contact to metal; specifying at this figure and running in free air destroys the heater
Continuous working temperature-50 u00b0C to +200 u00b0C continuous (+240 u00b0C intermittent)Of the heater itself, measured at the element, not the ambient
Dielectric strength2500 V AC, 1 minuteOne minute, element to any exposed surface, no breakdown
Insulation resistancegreater than 100 Mu03a9At 500 V DC, measured after the dielectric test
Lead wireSilicone-insulated stranded copper, 22 AWG to 16 AWG, PTFE where the exit is hotLength, gauge and termination to your drawing
AttachmentFree, 3M 468MP or 9077 PSA backing, vulcanised to the part, or mechanically clampedAdhesive-backed heaters need continuous contact pressure while curing
Sensor and control optionsNTC 10K B3950, PT100/PT1000, K-type thermocouple, KSD9700 bimetal thermostat, thermal cutoffFitted under the same insulation and tested as one assembly
Certifications availableUL 499 construction, IEC/EN 60335, UL 94 V-0 materials, RoHS, REACH, CEConstructions are built to these; the certificate covers the construction, not every outline
Standard sizes20 L pail, 200 L steel or plastic drum, 1000 L IBCNon-standard vessels are quoted from the circumference and height
ControlIntegral capillary thermostat 0-90 u00b0C, or external digital controllerA blanket on an empty drum reaches its own limit within minutes u2014 a control is not optional

Capability figures are this factory's process limits for the construction described. Watt density limits follow the published maxima for fibreglass-reinforced silicone rubber heaters (to about 12 W/cm² bonded to a heat sink, far less in free air); continuous temperature limits are those of the silicone insulation system, not of the element alloy.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.

Build the Drawing

The panel above checks whether a size and a wattage can be built. This is the drawing itself: set the outline, route the heating track, place the lead wires, terminals, connector and temperature sensor, working in silicone rubber, and turn the model to look at it. When it is right, export the 2D drawing as a PDF or a DXF and send it with your enquiry — a drawing is what a quotation for drum and ibc silicone heating blankets is actually written from.

HEATING FILM DRAWING
Silicone Rubber Heater

Draw the outline, route the heating track, place the lead exits, terminals and sensor, dimension it, then export a PDF or a DXF and send it with your enquiry. Nothing here is a stock part and nothing you draw commits you to anything.

CMD

Want to compare constructions before you draw? Open the full builder, where every film family is selectable in one place.

Our facility

Where these heaters are actually made

Circuit layout, element preparation, lamination and vulcanising, die cutting and lead attachment all happen under one roof, so a watt density limit and a temperature ceiling are set by processes we control and can evidence, not by whichever supplier had stock.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (UL 499 / IEC 60335 / RoHS)

ParameterSpecificationLimit / note
ConstructionNichrome resistance wire wound on a fibreglass carrier, or etched Inconel foil, vulcanised between two sheets of fibreglass-reinforced silicone rubberDecided at quotation from the outline and the wattage
Insulation systemFibreglass-reinforced silicone rubber, both facesThis is what sets the temperature limit, not the element
Total thickness2.0 mmNominal, before adhesive; add 0.2 mm for PSA backing
Minimum size25 x 25 mmBelow this the element cannot be routed with a safe edge margin
Maximum size, one piece2500 x 600 mmLarger areas are supplied as tiled zones with separate circuits
Dimensional toleranceu00b11.5 mm on dimensions up to 300 mm, u00b10.5%% aboveOn the die-cut outline; hole positions are held tighter
Supply voltage5 V DC to 240 V AC, wound to orderWound to the ordered voltage u2014 it is not a switchable range
Resistance toleranceu00b110% standard, u00b15% on requestMeasured at 20 u00b0C; hot resistance differs with the element alloy
Watt density, free air0.4 W/cmu00b2 typical, 0.6 W/cmu00b2 maximumNothing conducting heat away u2014 the honest figure for an unbonded heater
Watt density, bonded to heat sink2.0 W/cmu00b2 maximumOnly valid with full-area contact to metal; specifying at this figure and running in free air destroys the heater
Continuous working temperature-50 u00b0C to +200 u00b0C continuous (+240 u00b0C intermittent)Of the heater itself, measured at the element, not the ambient
Dielectric strength2500 V AC, 1 minuteOne minute, element to any exposed surface, no breakdown
Insulation resistancegreater than 100 Mu03a9At 500 V DC, measured after the dielectric test
Lead wireSilicone-insulated stranded copper, 22 AWG to 16 AWG, PTFE where the exit is hotLength, gauge and termination to your drawing
AttachmentFree, 3M 468MP or 9077 PSA backing, vulcanised to the part, or mechanically clampedAdhesive-backed heaters need continuous contact pressure while curing
Sensor and control optionsNTC 10K B3950, PT100/PT1000, K-type thermocouple, KSD9700 bimetal thermostat, thermal cutoffFitted under the same insulation and tested as one assembly
Certifications availableUL 499 construction, IEC/EN 60335, UL 94 V-0 materials, RoHS, REACH, CEConstructions are built to these; the certificate covers the construction, not every outline
Standard sizes20 L pail, 200 L steel or plastic drum, 1000 L IBCNon-standard vessels are quoted from the circumference and height
ControlIntegral capillary thermostat 0-90 u00b0C, or external digital controllerA blanket on an empty drum reaches its own limit within minutes u2014 a control is not optional

Video: Aramid Paper (Nomex type) Drum and IBC Silicone Heating Blankets

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

What temperature will Aramid Paper (Nomex type) stand?

To +180 °C continuous. That range is the insulation system's, and on a heater the insulation system is what sets the rating — the element will always outlast the material around it.

What are the weaknesses of Aramid Paper (Nomex type)?

Absorbs moisture, and its dielectric strength falls when it does.

What should I use instead of Aramid Paper (Nomex type) above its limit?

Aramid paper is a 180 °C insulation used where polyimide is unnecessary and silicone is too thick. Above it, silicone rubber and polyimide both reach 200 °C; above 200 °C the polymers stop altogether and the construction changes to a fired or mica-insulated one. Its weakness is moisture — it absorbs it, and its dielectric strength falls when it does — so a damp installation is a reason to move to silicone even well below the temperature limit.

What watt density can drum and ibc silicone heating blankets run at?

0.4 W/cm² with nothing conducting the heat away, and 2 W/cm² bonded over its whole area to metal. The two figures describe two different installations, not a range to choose from: a heater specified at 2 W/cm² and then run in free air reaches its insulation limit within minutes.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.