Skip to content
PTC Heaters · IEC 60335 / UL 499 / RoHS

CE Marking PTC Ceramic Heating Elements

What CE Marking fixes, what it deliberately leaves to another document, and how it is evidenced on a heater built to a customer drawing.

The manufacturer's declaration that the product meets the applicable EU directives — for a heater, usually the low voltage and EMC directives together with RoHS.

Standard
CE Marking
What it does not cover
CE is self-declared for most heating products; it is not a third-party approval and should not be presented as one.
Construction
PTC Ceramic Heating Elements
Built and tested to
IEC 60335 / UL 499 / RoHS
Insulation
Aluminium carrier with insulating film
Continuous temperature limit
300 °C continuous

A construction is built and tested to a standard. A heater made to your outline has no certified part number of its own, so the approval sits with the end product and with the file you hold — what this factory supplies is the construction, the materials and the test records that let that file be assembled.

PTC Ceramic Heating Elements — the construction this guide is about

A standard is a set of tests, not a property of a shape. CE Marking is one of the documents ptc ceramic heating elements are built to; the sections below say what it fixes, what it does not, and what has to be named on the enquiry for the approval to be usable.

CE Marking — Scope

The manufacturer's declaration that the product meets the applicable EU directives — for a heater, usually the low voltage and EMC directives together with RoHS.

What CE Marking Does Not Cover

CE is self-declared for most heating products; it is not a third-party approval and should not be presented as one.

This is the division of labour to carry away from any heating standard: safety standards decide whether the part can hurt somebody, and say nothing about whether it holds a temperature, lasts five years or matches the last batch. Performance is a specification you write; safety is one the standard writes.

And it is self-declared for most heating products. A CE mark is a manufacturer's statement that the applicable directives have been met, supported by a technical file — it is not a third-party approval, and any supplier presenting it as one is telling you something about themselves.

How a Made-to-Drawing Heater Is Certified

A construction is built and tested to a standard. The insulation system, the creepage and clearance distances, the earthing, the lead anchorage, the temperature under fault and the marking are what the test covers — and all of those are properties of the construction rather than of the outline it is die-cut to.

So a custom outline does not have a certificate of its own, and no supplier can honestly hand you one. What is available is the construction file: the standard the build is tested to, the materials list with their own ratings, and the test reports. That is what an approvals engineer needs, and it is what the end product's own certification is built on.

The practical consequence: name CE Marking on the enquiry, not after approval. A construction chosen for cost and then asked to pass a standard afterwards usually has to be rebuilt, because the insulation thickness, the creepage distances and the lead anchorage are decided at design time and are not adjustable later.

From the capability table: UL 499, IEC/EN 60335, RoHS, REACH, CE, IATF 16949.

What a PTC Ceramic Heating Elements Is

Bare electroded PTC ceramic elements for building into your own assembly, in the standard footprints and Curie points.

Barium titanate ceramic whose resistance rises steeply above its Curie point, so the power it draws falls as the surface approaches that temperature. The element cannot exceed the Curie point it was made to, whatever the supply or the control does.

The heat leaves through a clamped joint, and a clamped joint is only as good as the pressure and the flatness behind it. A thermal interface material or a thin film of thermal grease fills the gaps that machining leaves; without one, contact happens at the high spots and the element runs hotter than the plate it is bolted to.

Elementbarium titanate PTC ceramic
Insulation systemaluminium carrier with insulating film
Total thicknessElement 1.5 mm to 3 mm; assembly to your drawing
Maximum size, one piece5 x 20 mm to 25 x 60 mm
Continuous working temperature300 °C

The continuous limit of 300 °C is set by aluminium carrier with insulating film. The element alloy would run far hotter; it is never the element that decides.

The Other Standards This Construction Is Built To

A heater is rarely governed by one document. This construction is also built and tested to:

Safety, materials, substances and quality system are four separate questions with four separate documents behind them. A part can satisfy all four and still be the wrong heater for the duty, which is what the rest of this page is about.

Control and Protection

This is the one construction here that limits its own temperature. Above the Curie point the ceramic's resistance rises steeply, the current falls, and the element settles rather than climbing — so a PTC heater cannot thermally run away even with the control shorted out.

That is a safety property, not an accuracy one. Self-regulation holds a surface somewhere near the Curie point under whatever cooling it happens to have; it does not hold a set point, and the temperature it settles at moves with airflow, with supply voltage and with the load. Where a number has to be held, a sensor and a controller are still required.

Two things still have to be designed for: the inrush, which is several times the running current while the ceramic is cold and which the supply and any switching device must tolerate, and the electrical fault case, which self-regulation does nothing about — a fuse or a current-limited supply is still the protection against a short.

Watt Density: the Two Figures

This construction is rated at 0.5 W/cm² in free air and 3 W/cm² bonded over its whole area to metal. The second figure is 6 times the first, and the difference is not a safety margin — it is the heat sink. On a 100 x 150 mm outline, which is 150 cm², that is about 75 W hanging in air against about 45 W bonded down.

Specify at the figure that matches how the heater will actually run. A heater ordered at the bonded density and then switched on before it is attached — on the bench, during a test, after it has lifted off in service — reaches its insulation limit in minutes, because there is nowhere for the heat to go but through the insulation.

A PTC assembly behaves differently at the limit. Deprived of its heat sink it does not run away; it reduces its own power. The consequence of a poor thermal path here is a heater that delivers well under its nameplate power, not one that destroys itself.

Leads and Terminations

Termination is specified on the drawing: lead length, gauge, insulation and the connector or tag at the end of it.

Connector and termination options: Faston 2.8/4.8 mm, crimp, or flying leads. A keyed housing removes a soldering operation from the customer's line and removes the possibility of the assembly being connected backwards; on a heater with a separate sensor circuit it also stops the sensor pair being mistaken for the power pair.

The lead exit is a thermal discontinuity as well as an electrical one. The joint between a fine element and a stranded lead is the hottest point of many heaters, so it is kept out of the highest watt density zone, strain relieved, and — where the exit sits in a hot area — insulated in PTFE rather than in silicone.

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • An outline drawing, or a sketch with dimensions: overall size, holes, cut-outs, radii and the lead exit position.
  • The supply voltage, and whether it is AC or DC. The element is wound for one voltage; it is not a switchable range.
  • The power required, or — better — the temperature to be reached and the mass or flow it has to be reached in. Given the second, the wattage can be calculated instead of guessed.
  • What the heater is attached to, and how. This is what decides which watt density figure applies, and it is the question a quotation cannot proceed without.
  • The ambient, and the lowest temperature the assembly must start from. A heater sized for a 20 °C start is undersized for a -30 °C one.
  • Duty cycle: continuous, intermittent, or a warm-up to a deadline. Time to temperature is a specification, not a by-product.
  • Sensor and protection: which sensor, where it goes, and which limit device is fitted in series with the element.
  • The certification the end product is built to, named on the enquiry rather than after approval.
  • Quantity and target price, because the construction that is right for fifty pieces is often not the one that is right for fifty thousand.
  • The Curie point wanted, and the airflow or thermal path the assembly will have — both decide the power the element will actually deliver.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

PTC Ceramic Heating Elements — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
ConstructionBarium titanate PTC ceramic, electroded on both faces, in an aluminium carrierAssembly built around the element to suit the load
Curie temperature+60 u00b0C to +300 u00b0C, selectedSelected at order u2014 it is the surface temperature ceiling and cannot be adjusted afterwards
Self-regulationPower falls to a fraction of rated as the surface reaches the Curie pointNo thermostat is required to prevent runaway; one may still be wanted for control
Element size5 x 20 mm to 25 x 60 mmStandard element footprints; assemblies to your drawing
Supply voltage12 V, 24 V, 48 V, 110 V, 220 VThe same element works over a voltage band with different output
Power output0.5 W/cmu00b2 typical in still air, 3.0 W/cmu00b2 with forced airOutput is set by the airflow, not by a setting u2014 this is what self-regulating means
Inrush current3 to 8 times running current for 1 to 3 secondsThe supply and any relay or MOSFET must tolerate it
Dielectric strength1800 V AC, 1 minute, element to caseOn the assembled unit with its insulation in place
Insulation resistancegreater than 100 Mu03a9 at 500 V DC
TerminationsFaston 2.8/4.8 mm, crimp, or flying leadsChosen for the assembly temperature
LifeOver 10,000 hours at rated conditionsAgeing shows as a slow rise in cold resistance, not as sudden failure
Certifications availableUL 499, IEC/EN 60335, RoHS, REACH, CE, IATF 16949Construction level
MountingClamped between aluminium with thermally conductive siliconeContact pressure decides the output; a loosely held element self-limits at low power

Capability figures are for barium titanate PTC ceramic elements and the aluminium assemblies built around them. The defining property — that power falls steeply as the element approaches its Curie point, so surface temperature cannot run away — is inherent to the ceramic, not a feature of the control.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.
Our facility

Where these heaters are actually made

Circuit layout, element preparation, lamination and vulcanising, die cutting and lead attachment all happen under one roof, so a watt density limit and a temperature ceiling are set by processes we control and can evidence, not by whichever supplier had stock.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (IEC 60335 / UL 499 / RoHS)

ParameterSpecificationLimit / note
ConstructionBarium titanate PTC ceramic, electroded on both faces, in an aluminium carrierAssembly built around the element to suit the load
Curie temperature+60 u00b0C to +300 u00b0C, selectedSelected at order u2014 it is the surface temperature ceiling and cannot be adjusted afterwards
Self-regulationPower falls to a fraction of rated as the surface reaches the Curie pointNo thermostat is required to prevent runaway; one may still be wanted for control
Element size5 x 20 mm to 25 x 60 mmStandard element footprints; assemblies to your drawing
Supply voltage12 V, 24 V, 48 V, 110 V, 220 VThe same element works over a voltage band with different output
Power output0.5 W/cmu00b2 typical in still air, 3.0 W/cmu00b2 with forced airOutput is set by the airflow, not by a setting u2014 this is what self-regulating means
Inrush current3 to 8 times running current for 1 to 3 secondsThe supply and any relay or MOSFET must tolerate it
Dielectric strength1800 V AC, 1 minute, element to caseOn the assembled unit with its insulation in place
Insulation resistancegreater than 100 Mu03a9 at 500 V DC
TerminationsFaston 2.8/4.8 mm, crimp, or flying leadsChosen for the assembly temperature
LifeOver 10,000 hours at rated conditionsAgeing shows as a slow rise in cold resistance, not as sudden failure
Certifications availableUL 499, IEC/EN 60335, RoHS, REACH, CE, IATF 16949Construction level
MountingClamped between aluminium with thermally conductive siliconeContact pressure decides the output; a loosely held element self-limits at low power

Video: CE Marking PTC Ceramic Heating Elements

Ultimate Guide to the Best Top 5 PTC Ceramic Heating Elements For Electronics - 1PC Liquid Air Elect

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

How large can one piece be?

5 x 20 mm to 25 x 60 mm in a single piece. Larger areas are supplied as tiled zones with separate circuits, which is usually better engineering anyway: separate zones can be controlled separately, and a large single circuit has to carry the whole current at one lead exit.

Is this heater CE Marking approved?

The construction is built and tested to CE Marking; the outline is yours, and a made-to-drawing outline does not carry a certificate of its own. What is available is the construction file — the standard the build is tested to, the material ratings and the test reports — which is what your own product approval is built on.

What does CE Marking not cover?

CE is self-declared for most heating products; it is not a third-party approval and should not be presented as one. Safety standards decide whether a part can hurt somebody; they say nothing about whether it holds a temperature or lasts.

What watt density can ptc ceramic heating elements run at?

0.5 W/cm² with nothing conducting the heat away, and 3 W/cm² bonded over its whole area to metal. The two figures describe two different installations, not a range to choose from: a heater specified at 3 W/cm² and then run in free air reaches its insulation limit within minutes.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.