Skip to content
Silicone Rubber Heaters · UL 499 / IEC 60335 / RoHS

CE Marking Battery Silicone Heaters with Molex Connector

What CE Marking fixes, what it deliberately leaves to another document, and how it is evidenced on a heater built to a customer drawing.

The manufacturer's declaration that the product meets the applicable EU directives — for a heater, usually the low voltage and EMC directives together with RoHS.

Standard
CE Marking
What it does not cover
CE is self-declared for most heating products; it is not a third-party approval and should not be presented as one.
Construction
Battery Silicone Heaters with Molex Connector
Built and tested to
UL 499 / IEC 60335 / RoHS
Insulation
Fibreglass-reinforced silicone rubber
Continuous temperature limit
200 °C continuous

A construction is built and tested to a standard. A heater made to your outline has no certified part number of its own, so the approval sits with the end product and with the file you hold — what this factory supplies is the construction, the materials and the test records that let that file be assembled.

Battery Silicone Heaters with Molex Connector — the construction this guide is about

A standard is a set of tests, not a property of a shape. CE Marking is one of the documents battery silicone heaters with molex connector are built to; the sections below say what it fixes, what it does not, and what has to be named on the enquiry for the approval to be usable.

CE Marking — Scope

The manufacturer's declaration that the product meets the applicable EU directives — for a heater, usually the low voltage and EMC directives together with RoHS.

What CE Marking Does Not Cover

CE is self-declared for most heating products; it is not a third-party approval and should not be presented as one.

This is the division of labour to carry away from any heating standard: safety standards decide whether the part can hurt somebody, and say nothing about whether it holds a temperature, lasts five years or matches the last batch. Performance is a specification you write; safety is one the standard writes.

And it is self-declared for most heating products. A CE mark is a manufacturer's statement that the applicable directives have been met, supported by a technical file — it is not a third-party approval, and any supplier presenting it as one is telling you something about themselves.

How a Made-to-Drawing Heater Is Certified

A construction is built and tested to a standard. The insulation system, the creepage and clearance distances, the earthing, the lead anchorage, the temperature under fault and the marking are what the test covers — and all of those are properties of the construction rather than of the outline it is die-cut to.

So a custom outline does not have a certificate of its own, and no supplier can honestly hand you one. What is available is the construction file: the standard the build is tested to, the materials list with their own ratings, and the test reports. That is what an approvals engineer needs, and it is what the end product's own certification is built on.

The practical consequence: name CE Marking on the enquiry, not after approval. A construction chosen for cost and then asked to pass a standard afterwards usually has to be rebuilt, because the insulation thickness, the creepage distances and the lead anchorage are decided at design time and are not adjustable later.

From the capability table: UL 499 construction, IEC/EN 60335, UL 94 V-0 materials, RoHS, REACH, CE.

What a Battery Silicone Heaters with Molex Connector Is

The same battery heater terminated in a keyed connector instead of flying leads, so the pack is assembled without a soldering step and cannot be plugged in backwards.

Nichrome resistance wire, or an etched Inconel foil circuit, vulcanised between two sheets of fibreglass-reinforced silicone rubber. The construction is about 1.2 to 2 mm thick, conforms to a curved surface, and holds its dielectric strength from -50 °C up to 200 °C continuously. On a cell block the watt density is kept deliberately low: the object is to raise the whole pack a few degrees evenly, not to warm one face fast, and a hot spot against a cell is worse than no heater at all.

The heat leaves through the bonded face. Everything that is not in contact with the load radiates and convects from the back of the heater instead, which at these thicknesses is a poor path — so an air gap under part of the outline is not a small loss of efficiency, it is a hot spot at that spot.

Elementnichrome wire or etched Inconel foil
Insulation systemfibreglass-reinforced silicone rubber
Total thickness1.2 mm
Maximum size, one piece500 x 1000 mm (one piece)
Continuous working temperature200 °C

The continuous limit of 200 °C is set by fibreglass-reinforced silicone rubber. The element alloy would run far hotter; it is never the element that decides.

The Other Standards This Construction Is Built To

A heater is rarely governed by one document. This construction is also built and tested to:

Safety, materials, substances and quality system are four separate questions with four separate documents behind them. A part can satisfy all four and still be the wrong heater for the duty, which is what the rest of this page is about.

Control and Protection

This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.

The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.

Sensors can be built into the part: NTC thermistor, PT100 or PT1000 RTD, or a K-type thermocouple, fitted under the same insulation and tested with the heater as one assembly. A sensor laminated into the heater reads the heater; a sensor on the load reads the load. Both are legitimate, and the drawing has to say which is wanted.

Watt Density: the Two Figures

This construction is rated at 0.3 W/cm² in free air and 2 W/cm² bonded over its whole area to metal. The second figure is 6.7 times the first, and the difference is not a safety margin — it is the heat sink. On a 100 x 150 mm outline, which is 150 cm², that is about 45 W hanging in air against about 3 W bonded down.

Specify at the figure that matches how the heater will actually run. A heater ordered at the bonded density and then switched on before it is attached — on the bench, during a test, after it has lifted off in service — reaches its insulation limit in minutes, because there is nowhere for the heat to go but through the insulation.

Leads and Terminations

Lead wire as supplied: Silicone-insulated stranded copper, 22 AWG to 16 AWG, PTFE where the exit is hot. Length, gauge, exit position and termination are drawing items — the exit position in particular, because it decides where the heater can be routed and it cannot be changed after the tool is cut.

Connector and termination options: Molex Micro-Fit 3.0, Mini-Fit Jr, JST XH / PH / VH, TE MQS. A keyed housing removes a soldering operation from the customer's line and removes the possibility of the assembly being connected backwards; on a heater with a separate sensor circuit it also stops the sensor pair being mistaken for the power pair.

The lead exit is a thermal discontinuity as well as an electrical one. The joint between a fine element and a stranded lead is the hottest point of many heaters, so it is kept out of the highest watt density zone, strain relieved, and — where the exit sits in a hot area — insulated in PTFE rather than in silicone.

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • An outline drawing, or a sketch with dimensions: overall size, holes, cut-outs, radii and the lead exit position.
  • The supply voltage, and whether it is AC or DC. The element is wound for one voltage; it is not a switchable range.
  • The power required, or — better — the temperature to be reached and the mass or flow it has to be reached in. Given the second, the wattage can be calculated instead of guessed.
  • What the heater is attached to, and how. This is what decides which watt density figure applies, and it is the question a quotation cannot proceed without.
  • The ambient, and the lowest temperature the assembly must start from. A heater sized for a 20 °C start is undersized for a -30 °C one.
  • Duty cycle: continuous, intermittent, or a warm-up to a deadline. Time to temperature is a specification, not a by-product.
  • Sensor and protection: which sensor, where it goes, and which limit device is fitted in series with the element.
  • The certification the end product is built to, named on the enquiry rather than after approval.
  • Quantity and target price, because the construction that is right for fifty pieces is often not the one that is right for fifty thousand.
  • Whether adhesive backing is wanted, and what surface it goes onto — a low-energy plastic needs a different adhesive from bare aluminium.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

Battery Silicone Heaters with Molex Connector — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
ConstructionNichrome resistance wire wound on a fibreglass carrier, or etched Inconel foil, vulcanised between two sheets of fibreglass-reinforced silicone rubberDecided at quotation from the outline and the wattage
Insulation systemFibreglass-reinforced silicone rubber, both facesThis is what sets the temperature limit, not the element
Total thickness1.2 mmNominal, before adhesive; add 0.2 mm for PSA backing
Minimum size25 x 25 mmBelow this the element cannot be routed with a safe edge margin
Maximum size, one piece500 x 1000 mm (one piece)Larger areas are supplied as tiled zones with separate circuits
Dimensional toleranceu00b11.5 mm on dimensions up to 300 mm, u00b10.5%% aboveOn the die-cut outline; hole positions are held tighter
Supply voltage5 V DC to 240 V AC, wound to orderWound to the ordered voltage u2014 it is not a switchable range
Resistance toleranceu00b110% standard, u00b15% on requestMeasured at 20 u00b0C; hot resistance differs with the element alloy
Watt density, free air0.3 W/cmu00b2 typical, 0.4 W/cmu00b2 maximumNothing conducting heat away u2014 the honest figure for an unbonded heater
Watt density, bonded to heat sink2.0 W/cmu00b2 maximumOnly valid with full-area contact to metal; specifying at this figure and running in free air destroys the heater
Continuous working temperature-50 u00b0C to +200 u00b0C continuous (+240 u00b0C intermittent)Of the heater itself, measured at the element, not the ambient
Dielectric strength2500 V AC, 1 minuteOne minute, element to any exposed surface, no breakdown
Insulation resistancegreater than 100 Mu03a9At 500 V DC, measured after the dielectric test
Lead wireSilicone-insulated stranded copper, 22 AWG to 16 AWG, PTFE where the exit is hotLength, gauge and termination to your drawing
AttachmentFree, 3M 468MP or 9077 PSA backing, vulcanised to the part, or mechanically clampedAdhesive-backed heaters need continuous contact pressure while curing
Sensor and control optionsNTC 10K B3950, PT100/PT1000, K-type thermocouple, KSD9700 bimetal thermostat, thermal cutoffFitted under the same insulation and tested as one assembly
Certifications availableUL 499 construction, IEC/EN 60335, UL 94 V-0 materials, RoHS, REACH, CEConstructions are built to these; the certificate covers the construction, not every outline
Connector optionsMolex Micro-Fit 3.0, Mini-Fit Jr, JST XH / PH / VH, TE MQSHousing, pin plating and polarisation to your harness drawing
Sensor circuitSeparate 2-pin NTC circuit in the same housing or a second connectorKeeping power and signal in one housing saves a part and costs you noise immunity

Capability figures are this factory's process limits for the construction described. Watt density limits follow the published maxima for fibreglass-reinforced silicone rubber heaters (to about 12 W/cm² bonded to a heat sink, far less in free air); continuous temperature limits are those of the silicone insulation system, not of the element alloy.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.

Build the Drawing

The panel above checks whether a size and a wattage can be built. This is the drawing itself: set the outline, route the heating track, place the lead wires, terminals, connector and temperature sensor, working in silicone rubber, and turn the model to look at it. When it is right, export the 2D drawing as a PDF or a DXF and send it with your enquiry — a drawing is what a quotation for battery silicone heaters with molex connector is actually written from.

HEATING FILM DRAWING
Silicone Rubber Heater

Draw the outline, route the heating track, place the lead exits, terminals and sensor, dimension it, then export a PDF or a DXF and send it with your enquiry. Nothing here is a stock part and nothing you draw commits you to anything.

CMD

Want to compare constructions before you draw? Open the full builder, where every film family is selectable in one place.

Our facility

Where these heaters are actually made

Circuit layout, element preparation, lamination and vulcanising, die cutting and lead attachment all happen under one roof, so a watt density limit and a temperature ceiling are set by processes we control and can evidence, not by whichever supplier had stock.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (UL 499 / IEC 60335 / RoHS)

ParameterSpecificationLimit / note
ConstructionNichrome resistance wire wound on a fibreglass carrier, or etched Inconel foil, vulcanised between two sheets of fibreglass-reinforced silicone rubberDecided at quotation from the outline and the wattage
Insulation systemFibreglass-reinforced silicone rubber, both facesThis is what sets the temperature limit, not the element
Total thickness1.2 mmNominal, before adhesive; add 0.2 mm for PSA backing
Minimum size25 x 25 mmBelow this the element cannot be routed with a safe edge margin
Maximum size, one piece500 x 1000 mm (one piece)Larger areas are supplied as tiled zones with separate circuits
Dimensional toleranceu00b11.5 mm on dimensions up to 300 mm, u00b10.5%% aboveOn the die-cut outline; hole positions are held tighter
Supply voltage5 V DC to 240 V AC, wound to orderWound to the ordered voltage u2014 it is not a switchable range
Resistance toleranceu00b110% standard, u00b15% on requestMeasured at 20 u00b0C; hot resistance differs with the element alloy
Watt density, free air0.3 W/cmu00b2 typical, 0.4 W/cmu00b2 maximumNothing conducting heat away u2014 the honest figure for an unbonded heater
Watt density, bonded to heat sink2.0 W/cmu00b2 maximumOnly valid with full-area contact to metal; specifying at this figure and running in free air destroys the heater
Continuous working temperature-50 u00b0C to +200 u00b0C continuous (+240 u00b0C intermittent)Of the heater itself, measured at the element, not the ambient
Dielectric strength2500 V AC, 1 minuteOne minute, element to any exposed surface, no breakdown
Insulation resistancegreater than 100 Mu03a9At 500 V DC, measured after the dielectric test
Lead wireSilicone-insulated stranded copper, 22 AWG to 16 AWG, PTFE where the exit is hotLength, gauge and termination to your drawing
AttachmentFree, 3M 468MP or 9077 PSA backing, vulcanised to the part, or mechanically clampedAdhesive-backed heaters need continuous contact pressure while curing
Sensor and control optionsNTC 10K B3950, PT100/PT1000, K-type thermocouple, KSD9700 bimetal thermostat, thermal cutoffFitted under the same insulation and tested as one assembly
Certifications availableUL 499 construction, IEC/EN 60335, UL 94 V-0 materials, RoHS, REACH, CEConstructions are built to these; the certificate covers the construction, not every outline
Connector optionsMolex Micro-Fit 3.0, Mini-Fit Jr, JST XH / PH / VH, TE MQSHousing, pin plating and polarisation to your harness drawing
Sensor circuitSeparate 2-pin NTC circuit in the same housing or a second connectorKeeping power and signal in one housing saves a part and costs you noise immunity

Video: CE Marking Battery Silicone Heaters with Molex Connector

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

How large can one piece be?

500 x 1000 mm (one piece) in a single piece. Larger areas are supplied as tiled zones with separate circuits, which is usually better engineering anyway: separate zones can be controlled separately, and a large single circuit has to carry the whole current at one lead exit.

Is this heater CE Marking approved?

The construction is built and tested to CE Marking; the outline is yours, and a made-to-drawing outline does not carry a certificate of its own. What is available is the construction file — the standard the build is tested to, the material ratings and the test reports — which is what your own product approval is built on.

What does CE Marking not cover?

CE is self-declared for most heating products; it is not a third-party approval and should not be presented as one. Safety standards decide whether a part can hurt somebody; they say nothing about whether it holds a temperature or lasts.

What watt density can battery silicone heaters with molex connector run at?

0.3 W/cm² with nothing conducting the heat away, and 2 W/cm² bonded over its whole area to metal. The two figures describe two different installations, not a range to choose from: a heater specified at 2 W/cm² and then run in free air reaches its insulation limit within minutes.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.