Skip to content
Epoxy Heating Plates · UL 499 / IEC 60335 / RoHS

CE Marking Aluminium Substrate Epoxy Heaters

What CE Marking fixes, what it deliberately leaves to another document, and how it is evidenced on a heater built to a customer drawing.

The manufacturer's declaration that the product meets the applicable EU directives — for a heater, usually the low voltage and EMC directives together with RoHS.

Standard
CE Marking
What it does not cover
CE is self-declared for most heating products; it is not a third-party approval and should not be presented as one.
Construction
Aluminium Substrate Epoxy Heaters
Built and tested to
UL 499 / IEC 60335 / RoHS
Insulation
Thermally conductive filled epoxy
Continuous temperature limit
150 °C continuous

A construction is built and tested to a standard. A heater made to your outline has no certified part number of its own, so the approval sits with the end product and with the file you hold — what this factory supplies is the construction, the materials and the test records that let that file be assembled.

Aluminium Substrate Epoxy Heaters — the construction this guide is about

A standard is a set of tests, not a property of a shape. CE Marking is one of the documents aluminium substrate epoxy heaters are built to; the sections below say what it fixes, what it does not, and what has to be named on the enquiry for the approval to be usable.

CE Marking — Scope

The manufacturer's declaration that the product meets the applicable EU directives — for a heater, usually the low voltage and EMC directives together with RoHS.

What CE Marking Does Not Cover

CE is self-declared for most heating products; it is not a third-party approval and should not be presented as one.

This is the division of labour to carry away from any heating standard: safety standards decide whether the part can hurt somebody, and say nothing about whether it holds a temperature, lasts five years or matches the last batch. Performance is a specification you write; safety is one the standard writes.

And it is self-declared for most heating products. A CE mark is a manufacturer's statement that the applicable directives have been met, supported by a technical file — it is not a third-party approval, and any supplier presenting it as one is telling you something about themselves.

How a Made-to-Drawing Heater Is Certified

A construction is built and tested to a standard. The insulation system, the creepage and clearance distances, the earthing, the lead anchorage, the temperature under fault and the marking are what the test covers — and all of those are properties of the construction rather than of the outline it is die-cut to.

So a custom outline does not have a certificate of its own, and no supplier can honestly hand you one. What is available is the construction file: the standard the build is tested to, the materials list with their own ratings, and the test reports. That is what an approvals engineer needs, and it is what the end product's own certification is built on.

The practical consequence: name CE Marking on the enquiry, not after approval. A construction chosen for cost and then asked to pass a standard afterwards usually has to be rebuilt, because the insulation thickness, the creepage distances and the lead anchorage are decided at design time and are not adjustable later.

From the capability table: UL 499, IEC/EN 60335, RoHS, REACH, CE, IATF 16949.

What an Aluminium Substrate Epoxy Heaters Is

The thinnest epoxy construction: a foil element potted onto thin aluminium, for bonding to a curved or awkward assembly that still needs a rigid backing.

A resistance wire or foil element vacuum potted in thermally conductive filled epoxy against an aluminium or steel plate. Rigid, flat, sealed, and thermally bonded to its own plate so the heat leaves the element through metal rather than through air.

The plate is the thermal path: the element is potted against it, so the metal spreads the heat before the load ever sees it. That is what buys uniformity, and it is also what makes the assembly slow — a bolted plate takes minutes to reach steady state where a film takes seconds.

Elementresistance wire or foil, vacuum potted
Insulation systemthermally conductive filled epoxy
Total thickness2.5 mm to 6 mm
Maximum size, one piece250 x 400 mm
Continuous working temperature150 °C

The continuous limit of 150 °C is set by thermally conductive filled epoxy. The element alloy would run far hotter; it is never the element that decides.

The Other Standards This Construction Is Built To

A heater is rarely governed by one document. This construction is also built and tested to:

Safety, materials, substances and quality system are four separate questions with four separate documents behind them. A part can satisfy all four and still be the wrong heater for the duty, which is what the rest of this page is about.

Control and Protection

This heater has no way of limiting its own temperature. Resistance heating draws roughly the same power whatever the temperature, so with the load removed, the fluid gone, the fan stopped or the sensor open circuit, the element keeps producing watts until something stops it.

The design must therefore contain a control device and, separately, a protective one: a controller with a sensor to hold the set point, and a bimetal thermostat or a one-shot thermal cutoff wired in series with the element to open the circuit if the loop ever fails. The two are not interchangeable — a controller that has lost its sensor cannot protect anything, which is exactly the fault the cutoff exists for.

The limit that matters is the epoxy's, at 150 °C, and it is reached at the element long before the plate face reads anything alarming. Put the limit device in the potting against the element, not on the outside of the plate.

Sensors can be built into the part: NTC thermistor, PT100 or PT1000 RTD, or a K-type thermocouple, fitted under the same insulation and tested with the heater as one assembly. A sensor laminated into the heater reads the heater; a sensor on the load reads the load. Both are legitimate, and the drawing has to say which is wanted.

Watt Density: the Two Figures

Two watt densities are quoted because there are two thermal situations. With nothing conducting heat away, 0.4 W/cm² is what the insulation survives. Bonded to a heat sink over the full outline, 2.5 W/cm² is. Anything in between depends on the quality of the joint, and the joint is the customer's to make.

The failure is silent and quick: the element does not know how it is mounted, so at 2.5 W/cm² in free air the heat simply accumulates in the insulation until it degrades. This is the single most common way these heaters are destroyed, and it happens on the first run rather than after a year.

Attachment and Thermal Contact

The plate is drilled or tapped to your drawing and bolts to the machine. The heated face has to sit flat against the load; where it cannot, a thermal interface pad is worth more than extra wattage.

Allow for expansion. An aluminium plate 400 mm long grows about 1 mm between 20 °C and 130 °C, so a plate bolted rigidly at both ends will bow, and the bow lifts the middle of the heated face away from the load.

From the capability table: Tapped holes, clearance holes, studs or bonded.

The joint between the heated surface and the load carries every watt the element makes. Fill it: an interface pad, a thin film of thermal grease or a bonded assembly. Two dry surfaces bolted together are a thermal resistance, and that resistance appears as element temperature.

How to Specify One

This is a made-to-drawing part, so there is no catalogue number to quote. A quotation is built from the following, and the more of it that arrives with the enquiry the fewer rounds it takes:

  • An outline drawing, or a sketch with dimensions: overall size, holes, cut-outs, radii and the lead exit position.
  • The supply voltage, and whether it is AC or DC. The element is wound for one voltage; it is not a switchable range.
  • The power required, or — better — the temperature to be reached and the mass or flow it has to be reached in. Given the second, the wattage can be calculated instead of guessed.
  • What the heater is attached to, and how. This is what decides which watt density figure applies, and it is the question a quotation cannot proceed without.
  • The ambient, and the lowest temperature the assembly must start from. A heater sized for a 20 °C start is undersized for a -30 °C one.
  • Duty cycle: continuous, intermittent, or a warm-up to a deadline. Time to temperature is a specification, not a by-product.
  • Sensor and protection: which sensor, where it goes, and which limit device is fitted in series with the element.
  • The certification the end product is built to, named on the enquiry rather than after approval.
  • Quantity and target price, because the construction that is right for fifty pieces is often not the one that is right for fifty thousand.
  • The plate material, thickness and mounting hole pattern, and what the plate is bolted to.

Lead time: Samples 7-10 days from approved drawing; production 15-20 days.

Aluminium Substrate Epoxy Heaters — Capability Table

These are process limits for the construction, not the specification of one stocked item. Every line is what the factory can hold; what your part holds is fixed on your drawing.

ParameterSpecificationLimit / note
ConstructionResistance wire or foil element potted in thermally conductive filled epoxy on a metal plateCured under vacuum so there are no voids in the heat path
Plate materialAluminium 1050 or 3003, 1 mm to 3 mmAluminium for spreading, stainless where the chemistry demands it
Total thickness2.5 mm to 6 mmPlate plus encapsulation
Maximum size, one piece250 x 400 mmLarger plates are built as multiple circuits on one plate
Dimensional toleranceu00b10.5 mm on the plate, u00b11 mm on the encapsulation
Supply voltage12 V, 24 V, 110 V, 220 VWound to order
Resistance toleranceu00b110%At 20 u00b0C
Watt density0.4 W/cmu00b2 typical, 2.5 W/cmu00b2 maximumAgainst a load in contact; free-standing operation runs far lower
Continuous working temperature-40 u00b0C to +150 u00b0CSet by the epoxy, not by the element
Dielectric strength2500 V AC, 1 minuteElement to plate
Insulation resistancegreater than 100 Mu03a9 at 500 V DCAlso after 48 hours humidity conditioning
Ingress protectionIP65 as standard, IP67 with a moulded lead entryThe encapsulation is the seal
MountingTapped holes, clearance holes, studs or bondedMachined into the plate before potting
Sensor optionsNTC, PT100 or thermostat potted into the same plateReads the plate, which is what the load actually sees
Certifications availableUL 499, IEC/EN 60335, RoHS, REACH, CE, IATF 16949Construction level

Capability figures are for resistance elements encapsulated in thermally conductive filled epoxy on a metal plate. The +150 °C continuous limit is a property of the encapsulant, and it is the lowest limit of any construction in this catalog — the element and the plate would both tolerate far more.

Outline & Specification Builder

Set the outline, the size, the voltage and the power you have in mind. The drawing redraws to match, and the panel works out the heated area, the watt density and the current — then checks that watt density against what this construction survives in free air and bonded to a heat sink. Those two limits are different by several times, and it is the difference that decides whether a heater lasts.

Fills in the form below; attach your outline drawing or DXF there.

Build the Drawing

The panel above checks whether a size and a wattage can be built. This is the drawing itself: set the outline, route the heating track, place the lead wires, terminals, connector and temperature sensor, working in custom outline, and turn the model to look at it. When it is right, export the 2D drawing as a PDF or a DXF and send it with your enquiry — a drawing is what a quotation for aluminium substrate epoxy heaters is actually written from.

HEATING FILM DRAWING
Custom / Special-Shaped Heating Film

Draw the outline, route the heating track, place the lead exits, terminals and sensor, dimension it, then export a PDF or a DXF and send it with your enquiry. Nothing here is a stock part and nothing you draw commits you to anything.

CMD

Want to compare constructions before you draw? Open the full builder, where every film family is selectable in one place.

Our facility

Where these heaters are actually made

Circuit layout, element preparation, lamination and vulcanising, die cutting and lead attachment all happen under one roof, so a watt density limit and a temperature ceiling are set by processes we control and can evidence, not by whichever supplier had stock.

Insulation film fed from the roll
Vulcanising press closing on a lay-up
Heater outlines being die cut
Finished heaters batched for dispatch

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

The part

If you have an outline drawing or a DXF, say so in the notes and we will reply with an address to send it to — a drawing turns an estimate into a quotation.

Business Information

Dimensions & Specifications (UL 499 / IEC 60335 / RoHS)

ParameterSpecificationLimit / note
ConstructionResistance wire or foil element potted in thermally conductive filled epoxy on a metal plateCured under vacuum so there are no voids in the heat path
Plate materialAluminium 1050 or 3003, 1 mm to 3 mmAluminium for spreading, stainless where the chemistry demands it
Total thickness2.5 mm to 6 mmPlate plus encapsulation
Maximum size, one piece250 x 400 mmLarger plates are built as multiple circuits on one plate
Dimensional toleranceu00b10.5 mm on the plate, u00b11 mm on the encapsulation
Supply voltage12 V, 24 V, 110 V, 220 VWound to order
Resistance toleranceu00b110%At 20 u00b0C
Watt density0.4 W/cmu00b2 typical, 2.5 W/cmu00b2 maximumAgainst a load in contact; free-standing operation runs far lower
Continuous working temperature-40 u00b0C to +150 u00b0CSet by the epoxy, not by the element
Dielectric strength2500 V AC, 1 minuteElement to plate
Insulation resistancegreater than 100 Mu03a9 at 500 V DCAlso after 48 hours humidity conditioning
Ingress protectionIP65 as standard, IP67 with a moulded lead entryThe encapsulation is the seal
MountingTapped holes, clearance holes, studs or bondedMachined into the plate before potting
Sensor optionsNTC, PT100 or thermostat potted into the same plateReads the plate, which is what the load actually sees
Certifications availableUL 499, IEC/EN 60335, RoHS, REACH, CE, IATF 16949Construction level

Video: CE Marking Aluminium Substrate Epoxy Heaters

Alumilite Explains: Epoxy Heat Resistance vs Heat Deflection Temperature

Third-party video, selected automatically for this topic. It is not produced by Heating Film and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

What is the maximum temperature of aluminium substrate epoxy heaters?

150 °C continuous, measured at the element. The limit belongs to thermally conductive filled epoxy and not to the element alloy, so it is not a figure that can be extended by derating the power.

Does this heater need a thermostat?

Yes. It has no mechanism for limiting its own temperature — with the load removed or the control loop failed it keeps producing the same power — so the design needs a controller with a sensor to hold the set point and, separately, a bimetal thermostat or a one-shot thermal cutoff in series with the element as protection.

Is there a part number I can order?

No — these are made to your drawing, so a part number would describe something that was never built. A quotation needs the outline, the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. The table on this page is what the factory can hold, not a stock list.

How large can one piece be?

250 x 400 mm in a single piece. Larger areas are supplied as tiled zones with separate circuits, which is usually better engineering anyway: separate zones can be controlled separately, and a large single circuit has to carry the whole current at one lead exit.

How do I request a quotation?

Send the outline drawing with the supply voltage, the power or the target temperature, what the heater is bonded to, the ambient and the duty cycle. We respond within one business day.